Abstract

Background In order to acquire accurate drug pharmacokinetic information, which is required for tissue dosimetry, micro-SPECT must be quantitative to allow for an accurate assessment of radioligand activity in the relevant tissue. This study investigates the feasibility of deriving accurate mouse-specific time-integrated drug pharmacokinetic data in mouse kidneys from activity measurements using micro-SPECT. Methods An animal experiment was carried out to evaluate the accuracy of 131 I activity quantification in mouse kidneys (mean tissue volume of 0.140 mL) using a micro-SPECT system against conventional ex vivo gamma counting (GC) in a NaI(Tl) detector. The imaging setting investigated was that of the mouse biodistribution of a 131 I-labelled single-domain antibody fragment (sdAb), currently being investigated for targeted radionuclide therapy of HER2-expressing cancer. SPECT imaging of 131 I 365-keV photons was done with a VECTor/CT system (MILabs, Netherlands) using a high-energy mouse collimator with 1.6-mm-diameter pinholes. For both activity quantification techniques, the pharmacokinetic profile of the radioligand from approximately 1–73 h p.i. was derived and the time-integrated activity coefficient per gram of tissue ( ã / M ) was estimated. Additionally, SPECT activity recovery coefficients were determined in a phantom setting. Results SPECT activities underestimate the reference activities by an amount that is dependent on the 131 I activity concentration in the kidney, and thus on the time point of the pharmacokinetic profile. This underestimation is around − 12% at 1.5 h (2.89 MBq mL −1 mean reference activity concentration), − 13% at 6.6 h (149 kBq mL −1 ), − 40% at 24 h (17.6 kBq mL −1 ) and − 46% at 73 h (5.2 kBq mL −1 ) p.i. The ã / M value estimated from SPECT activities is, nevertheless, within − 14% from the reference (GC) ã / M value. Furthermore, better quantitative accuracy (within 2% from GC) in the SPECT ã / M value is achieved when SPECT activities are compensated for partial recovery with a phantom-based recovery coefficient of 0.85. Conclusion The SPECT imaging system used, together with a robust activity quantification methodology, allows an accurate estimation of time-integrated pharmacokinetic information of the 131 I-labelled sdAb in mouse kidneys. This opens the possibility to perform mouse-specific kidney-tissue dosimetry based on pharmacokinetic data acquired in vivo on the same mice used in nephrotoxicity studies.

Abstract licence: CC BY-NC-ND

References27

    27 more references, whose wording the paper’s licence keeps private.

    Reads

    Read by people on this page

    None yet.

    Checked or read by AI through naulon

    None yet.

    A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

    Are you an author?

    Is this your paper?

    Claim it to add your note and be paid when agents cite it. Free.