Skip to content
naulon

Not checkedNot checked for notices yet.

Hydrochemical aspects of high-temperature aquifer storage in carbonaceous aquifers: evaluation of a field study

Martina Ueckert, Thomas Baumann

Geothermal Energy · 2019

doi:10.1186/s40517-019-0120-0 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

Abstract Aquifer thermal energy storage systems in the sediments of the Upper Jurassic in the north-eastern part of the Bavarian Molasse Basin seem to be feasible in terms of the hydrogeological and hydrochemical setting. This study presents unique results from the first large-scale high-temperature heat storage test in these sediments and a hydrogeochemical model based and validated with the field data. The test was run in a single well setting with five injection and production cycles and temperatures from 65 to 110 °C. The flow rates were 15 L/s. Due to the very high transmissivity, mixing and density–driven flow have been observed and confirmed by hydrochemical analyses. Mixing was quantified using the natural contrast of the sodium ion concentrations as a natural tracer. Using the mixing ratios, a deduction of the effects of mixing on the temperature of the produced water was possible and a correction was applied to the recovered energy. The temperatures of the produced water show that 48% of the injected energy was recovered during the field test and the remaining energy is “charging” the aquifer. A kinetic hydrogeochemical model including 1D-transport was developed with PhreeqC to quantify the reactions in the reservoir and calibrated with the hydrochemical data of the first and second phase of the field test. The other three phases of the field test were used for validation. Model and measurement data were in excellent agreement and show significant dissolution of carbonates which can be attributed to an undersaturation of the water as it equilibrates with the matrix at lower temperatures. Based on field data from the single well test and the calibrated model, the operation of an ATES system was designed and simulated. Model results indicate that a doublet setting for ATES cannot be operated for more than a few cycles, regardless of the conditioning methods. In a triplet system, however, the time frame for successful operation can be extended to decades.

Abstract licence: CC BY

References18

    18 more references, whose wording the paper’s licence keeps private.

    Reads

    Read by people on this page

    None yet.

    Checked or read by AI through naulon

    None yet.

    A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

    Are you an author?

    Is this your paper?

    Claim it to add your note and be paid when agents cite it. Free.