Not checkedNot checked for notices yet.
TIP, TORQUE & ROTATIONS: How accurately do digital superimposition software packages quantify tooth movement?
Samar M. Adel, Nikhilesh R. Vaid, Nadia El-Harouni and 2 more
Progress in Orthodontics · 2022
doi:10.1186/s40510-022-00402-x (opens in a new tab)
We email you when a new notice or a question about this paper appears.
Abstract
Abstract Background To investigate the accuracy of three different 3D digital model registration software for tip, torque and rotation measurements, with reference to a 3D digital virtual setup. Twenty maxillary and mandibular pre-treatment scans of patients undergoing clear aligner therapy were used. Digital setups were generated from pre-treatment scans using a tooth movement software. Both the pretreatment digital scans (T1) and digital setups (T2) were converted to STL files to be exported to the 3 studied software that employed: (1) Semiautomatic best fit registration (S-BF), (2) Interactive surface-based registration (I-SB), and (3) Automatic best fit registration (A-BF) respectively. Changes in tip, torque and rotation were calculated for all the registered pairs. Results The change in tooth position was compared between the calculated tooth movement using each of the registration software packages versus the actual generated tooth movement from the digital setups. Continuous data was expressed as mean and standard deviation. Intra Class Correlation Coefficient for agreement between digital simulation and each software was used. Intra and Inter-examiner reliabilities were also assessed using Intra Class Correlation Coefficient. Significance of the obtained results was expressed at p ≤ 0.01. Semiautomatic best fit registration software showed excellent agreement (> 0.90) for all tooth movements, except for good agreement for torque (0.808). Interactive surface-based registration software showed moderate agreement for all measurements (0.50 and < 0.75), except for good agreement for rotation (0.783). Automatic best fit registration software demonstrated excellent agreement (> 0.90) for rotation, good agreement for tip (0.890) and moderate agreement for torque (0.740). Conclusions Overall, semiautomatic best fit registration software consistently showed excellent agreement in superimpositions compared to other software types. Automatic best fit registration software consistently demonstrated better agreement for mandibular superimpositions, compared to others. Accuracy of digital model superimpositions for tooth movements studied in superimposition studies, can be attributed to the algorithm employed for quantification.
Abstract licence: CC BY-NC-ND
References42
40 more references, whose wording the paper’s licence keeps private.
All 42 referencesReads
Read by people on this page
None yet.
Checked or read by AI through naulon
None yet.
A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.
Are you an author?
Is this your paper?
Claim it to add your note and be paid when agents cite it. Free.