Skip to content
naulon

No retraction, correction or concern found when last checked on Oct 30, 2026.

Prediction of fluid responsiveness. What’s new?

Xavier Monnet, Rui Shi, Jean-Louis Teboul

Annals of Intensive Care · 2022 · Review · CC BY-NC-ND

doi:10.1186/s13613-022-01022-8

Abstract

Although the administration of fluid is the first treatment considered in almost all cases of circulatory failure, this therapeutic option poses two essential problems: the increase in cardiac output induced by a bolus of fluid is inconstant, and the deleterious effects of fluid overload are now clearly demonstrated. This is why many tests and indices have been developed to detect preload dependence and predict fluid responsiveness. In this review, we take stock of the data published in the field over the past three years. Regarding the passive leg raising test, we detail the different stroke volume surrogates that have recently been described to measure its effects using minimally invasive and easily accessible methods. We review the limits of the test, especially in patients with intra-abdominal hypertension. Regarding the end-expiratory occlusion test, we also present recent investigations that have sought to measure its effects without an invasive measurement of cardiac output. Although the limits of interpretation of the respiratory variation of pulse pressure and of the diameter of the vena cava during mechanical ventilation are now well known, several recent studies have shown how changes in pulse pressure variation itself during other tests reflect simultaneous changes in cardiac output, allowing these tests to be carried out without its direct measurement. This is particularly the case during the tidal volume challenge, a relatively recent test whose reliability is increasingly well established. The mini-fluid challenge has the advantage of being easy to perform, but it requires direct measurement of cardiac output, like the classic fluid challenge. Initially described with echocardiography, recent studies have investigated other means of judging its effects. We highlight the problem of their precision, which is necessary to evidence small changes in cardiac output. Finally, we point out other tests that have appeared more recently, such as the Trendelenburg manoeuvre, a potentially interesting alternative for patients in the prone position.

Shown for reading. Its publisher allows quoting it, not republishing it.

References 112

  1. 1.
  2. 2.
  3. 3.

    Tigabu BM, Davari M, Kebriaeezadeh A, Mojtahedzadeh M. Fluid volume, fluid balance and patient outcome in severe sepsis and septic shock: a systematic review. J Crit Care. 2018;48:153-159.

    Not in our library10.1016/j.jcrc.2018.08.018

  4. 4.
  5. 5.

    Guerin L, Teboul JL, Persichini R, Dres M, Richard C, Monnet X. Effects of passive leg raising and volume expansion on mean systemic pressure and venous return in shock in humans. Crit Care. 2015;19:411.

    Not in our library10.1186/s13054-015-1115-2

  6. 6.

    Jabot J, Teboul JL, Richard C, Monnet X. Passive leg raising for predicting fluid responsiveness: importance of the postural change. Intensive Care Med. 2009;35:85-90.

    Not in our library10.1007/s00134-008-1293-3

  7. 7.

    Mesquida J, Gruartmoner G, Ferrer R. Passive leg raising for assessment of volume responsiveness: a review. Curr Opin Crit Care. 2017;23:237-243.

    Not in our library10.1097/mcc.0000000000000404

  8. 8.

    Pickett JD, Bridges E, Kritek PA, Whitney JD. Passive leg-raising and prediction of fluid responsiveness: systematic review. Crit Care Nurse. 2017;37:32-47.

    Not in our library10.4037/ccn2017205

  9. 9.

    Monnet X, Marik P, Teboul JL. Passive leg raising for predicting fluid responsiveness: a systematic review and meta-analysis. Intensive Care Med. 2016;42:1935-1947.

    Not in our library10.1007/s00134-015-4134-1

  10. 10.

    Cherpanath TG, Hirsch A, Geerts BF, Lagrand WK, Leeflang MM, Schultz MJ, et al. predicting fluid responsiveness by passive leg raising: a systematic review and meta-analysis of 23 clinical trials. Crit Care Med. 2016;44:981-991.

    Not in our library10.1097/ccm.0000000000001556

  11. 11.

    Monnet X, Dres M, Ferre A, Le Teuff G, Jozwiak M, Bleibtreu A, et al. Prediction of fluid responsiveness by a continuous non-invasive assessment of arterial pressure in critically ill patients: comparison with four other dynamic indices. Br J Anaesth. 2012;109:330-338.

    Not in our library10.1093/bja/aes182

  12. 12.

    Evans L, Rhodes A, Alhazzani W, Antonelli M, Coopersmith CM, French C, et al. Executive summary: surviving sepsis campaign: international guidelines for the management of sepsis and septic shock 2021. Crit Care Med. 2021;49:1974-1982.

    Not in our library10.1097/ccm.0000000000005357

  13. 13.

    Pickett JD, Bridges E, Kritek PA, Whitney JD. Noninvasive blood pressure monitoring and prediction of fluid responsiveness to passive leg raising. Am J Crit Care. 2018;27:228-237.

    Not in our library10.4037/ajcc2018867

  14. 14.

    Monnet X, Letierce A, Hamzaoui O, Chemla D, Anguel N, Osman D, et al. Arterial pressure allows monitoring the changes in cardiac output induced by volume expansion but not by norepinephrine*. Crit Care Med. 2011;39:1394-1399.

    Not in our library10.1097/ccm.0b013e31820edcf0

  15. 15.

    Jozwiak M, Monnet X, Teboul JL. Pressure waveform analysis. Anesth Analg. 2018;126:1930-1933.

    Not in our library10.1213/ane.0000000000002527

  16. 16.

    Teboul JL, Saugel B, Cecconi M, De Backer D, Hofer CK, Monnet X, et al. Less invasive hemodynamic monitoring in critically ill patients. Intensive Care Med. 2016;42:1350-1359.

    Not in our library10.1007/s00134-016-4375-7

  17. 17.

    Ameloot K, Palmers PJ, Malbrain ML. The accuracy of noninvasive cardiac output and pressure measurements with finger cuff: a concise review. Curr Opin Crit Care. 2015;21:232-239.

    Not in our library10.1097/mcc.0000000000000198

  18. 18.

    Monnet X, Bataille A, Magalhaes E, Barrois J, Le Corre M, Gosset C, et al. End-tidal carbon dioxide is better than arterial pressure for predicting volume responsiveness by the passive leg raising test. Intensive Care Med. 2013;39:93-100.

    Not in our library10.1007/s00134-012-2693-y

  19. 19.

    Monge Garcia MI, Gil Cano A, Gracia Romero M, Monterroso Pintado R, Perez Madueno V, Diaz Monrove JC. Non-invasive assessment of fluid responsiveness by changes in partial end-tidal CO2 pressure during a passive leg-raising maneuver. Ann Intensive Care. 2012;2:9.

    Not in our library10.1186/2110-5820-2-9

  20. 20.

    Toupin F, Clairoux A, Deschamps A, Lebon JS, Lamarche Y, Lambert J, et al. Assessment of fluid responsiveness with end-tidal carbon dioxide using a simplified passive leg raising maneuver: a prospective observational study. Can J Anaesth. 2016;63:1033-1041.

    Not in our library10.1007/s12630-016-0677-z

  21. 21.

    Galarza L, Mercado P, Teboul JL, Girotto V, Beurton A, Richard C, et al. Estimating the rapid haemodynamic effects of passive leg raising in critically ill patients using bioreactance. Br J Anaesth. 2018;121:567-573.

    Not in our library10.1016/j.bja.2018.03.013

  22. 22.
  23. 23.

    Li L, Ai Y, Huang L, Ai M, Peng Q, Zhang L. Can bioimpedance cardiography assess hemodynamic response to passive leg raising in critically ill patients: a STROBE-compliant study. Medicine (Baltimore). 2020;99:e23764.

    Not in our library10.1097/md.0000000000023764

  24. 24.

    Elshal MM, Hasanin AM, Mostafa M, Gamal RM. Plethysmographic peripheral perfusion index: could it be a new vital sign? Front Med (Lausanne). 2021;8:651909.

    Not in our library10.3389/fmed.2021.651909

  25. 25.

    Cannesson M, Desebbe O, Rosamel P, Delannoy B, Robin J, Bastien O, et al. Pleth variability index to monitor the respiratory variations in the pulse oximeter plethysmographic waveform amplitude and predict fluid responsiveness in the operating theatre. Br J Anaesth. 2008;101:200-206.

    Not in our library10.1093/bja/aen133

  26. 26.

    Monnet X, Guerin L, Jozwiak M, Bataille A, Julien F, Richard C, et al. Pleth variability index is a weak predictor of fluid responsiveness in patients receiving norepinephrine. Br J Anaesth. 2013;110:207-213.

    Not in our library10.1093/bja/aes373

  27. 27.

    Beurton A, Gavelli F, Teboul JL, De Vita N, Monnet X. Changes in the plethysmographic perfusion index during an end-expiratory occlusion detect a positive passive leg raising test. Crit Care Med. 2021;49:e151-e160.

    Not in our library10.1097/ccm.0000000000004768

  28. 28.

    Beurton A, Teboul JL, Gavelli F, Gonzalez FA, Girotto V, Galarza L, et al. The effects of passive leg raising may be detected by the plethysmographic oxygen saturation signal in critically ill patients. Crit Care. 2019;23:19.

    Not in our library10.1186/s13054-019-2306-z

  29. 29.

    Taccheri T, Gavelli F, Teboul JL, Shi R, Monnet X. Do changes in pulse pressure variation and inferior vena cava distensibility during passive leg raising and tidal volume challenge detect preload responsiveness in case of low tidal volume ventilation? Crit Care. 2021;25:110.

    Not in our library10.1186/s13054-021-03515-7

  30. 30.

    Hamzaoui O, Shi R, Carelli S, Sztrymf B, Prat D, Jacobs F, et al. Changes in pulse pressure variation to assess preload responsiveness in mechanically ventilated patients with spontaneous breathing activity: an observational study. Br J Anaesth. 2021;127:532-538.

    Not in our library10.1016/j.bja.2021.05.034

  31. 31.

    Ma GG, Tu GW, Zheng JL, Zhu DM, Hao GW, Hou JY, et al. Changes in stroke volume variation induced by passive leg raising to predict fluid responsiveness in cardiac surgical patients with protective ventilation. J Cardiothorac Vasc Anesth. 2020;34:1526-1533.

    Not in our library10.1053/j.jvca.2019.10.002

  32. 32.

    Jacquet-Lagreze M, Bouhamri N, Portran P, Schweizer R, Baudin F, Lilot M, et al. Capillary refill time variation induced by passive leg raising predicts capillary refill time response to volume expansion. Crit Care. 2019;23:281.

    Not in our library10.1186/s13054-019-2560-0

  33. 33.

    Barjaktarevic I, Toppen WE, Hu S, Aquije ME, Ong S, Buhr R, et al. Ultrasound assessment of the change in carotid corrected flow time in fluid responsiveness in undifferentiated shock. Crit Care Med. 2018;46:e1040-e1046.

    Not in our library10.1097/ccm.0000000000003356

  34. 34.

    Girotto V, Teboul JL, Beurton A, Galarza L, Guedj T, Richard C, et al. Carotid and femoral Doppler do not allow the assessment of passive leg raising effects. Ann Intensive Care. 2018;8:67.

    Not in our library10.1186/s13613-018-0413-7

  35. 35.

    Chowhan G, Kundu R, Maitra S, Arora MK, Batra RK, Subramaniam R, et al. Efficacy of left ventricular outflow tract and carotid artery velocity time integral as predictors of fluid responsiveness in patients with sepsis and septic shock. Indian J Crit Care Med. 2021;25:310-316.

    Not in our library10.5005/jp-journals-10071-23764

  36. 36.

    van Houte J, Mooi FJ, Montenij LJ, Meijs LPB, Suriani I, Conjaerts BCM, et al. Correlation of carotid Doppler blood flow with invasive cardiac output measurements in cardiac surgery patients. J Cardiothorac Vasc Anesth. 2021;36(4):1081-1091.

    Not in our library10.1053/j.jvca.2021.09.043

  37. 37.

    Roehrig C, Govier M, Robinson J, Aneman A. Carotid Doppler flowmetry correlates poorly with thermodilution cardiac output following cardiac surgery. Acta Anaesthesiol Scand. 2017;61:31-38.

    Not in our library10.1111/aas.12822

  38. 38.

    Monnet X, Teboul JL. Prediction of fluid responsiveness in spontaneously breathing patients. Ann Transl Med. 2020;8:790.

    Not in our library10.21037/atm-2020-hdm-18

  39. 39.

    Beurton A, Teboul JL, Girotto V, Galarza L, Anguel N, Richard C, et al. Intra-abdominal hypertension is responsible for false negatives to the passive leg raising test. Crit Care Med. 2019;47:e639-e647.

    Not in our library10.1097/ccm.0000000000003808

  40. 40.

    Minini A, Abraham P, Malbrain M. Predicting fluid responsiveness with the passive leg raising test: don't be fooled by intra-abdominal hypertension! Ann Transl Med. 2020;8:799.

    Not in our library10.21037/atm.2019.12.14

  41. 41.

    Jozwiak M, Monnet X, Teboul JL. Prediction of fluid responsiveness in ventilated patients. Ann Transl Med. 2018;6:352.

    Not in our library10.21037/atm.2018.05.03

  42. 42.

    Gavelli F, Teboul JL, Monnet X. The end-expiratory occlusion test: please, let me hold your breath! Crit Care. 2019;23:274.

    Not in our library10.1186/s13054-019-2554-y

  43. 43.

    Gavelli F, Shi R, Teboul JL, Azzolina D, Monnet X. The end-expiratory occlusion test for detecting preload responsiveness: a systematic review and meta-analysis. Ann Intensive Care. 2020;10:65.

    Not in our library10.1186/s13613-020-00682-8

  44. 44.

    Si X, Song X, Lin Q, Nie Y, Zhang G, Xu H, et al. does end-expiratory occlusion test predict fluid responsiveness in mechanically ventilated patients? A systematic review and meta-analysis. Shock. 2020;54:751-760.

    Not in our library10.1097/shk.0000000000001545

  45. 45.

    Messina A, Dell'Anna A, Baggiani M, Torrini F, Maresca GM, Bennett V, et al. Functional hemodynamic tests: a systematic review and a metanalysis on the reliability of the end-expiratory occlusion test and of the mini-fluid challenge in predicting fluid responsiveness. Crit Care. 2019;23:264.

    Not in our library10.1186/s13054-019-2545-z

  46. 46.

    Monnet X, Osman D, Ridel C, Lamia B, Richard C, Teboul JL. Predicting volume responsiveness by using the end-expiratory occlusion in mechanically ventilated intensive care unit patients. Crit Care Med. 2009;37:951-956.

    Not in our library10.1097/ccm.0b013e3181968fe1

  47. 47.

    de Courson H, Ferrer L, Cane G, Verchere E, Sesay M, Nouette-Gaulain K, et al. Evaluation of least significant changes of pulse contour analysis-derived parameters. Ann Intensive Care. 2019;9:116.

    Not in our library10.1186/s13613-019-0590-z

  48. 48.
  49. 49.

    Jozwiak M, Depret F, Teboul JL, Alphonsine JE, Lai C, Richard C, et al. Predicting fluid responsiveness in critically ill patients by using combined end-expiratory and end-inspiratory occlusions with echocardiography. Crit Care Med. 2017;45:e1131-e1138.

    Not in our library10.1097/ccm.0000000000002704

  50. 50.

    Depret F, Jozwiak M, Teboul JL, Alphonsine JE, Richard C, Monnet X. Esophageal Doppler can predict fluid responsiveness through end-expiratory and end-inspiratory occlusion tests. Crit Care Med. 2019;47:e96-e102.

    Not in our library10.1097/ccm.0000000000003522

  51. 51.

    Kenny JS, Barjaktarevic I, Eibl AM, Parrotta M, Long BF, Eibl JK. A wearable carotid Doppler tracks changes in the descending aorta and stroke volume induced by end-inspiratory and end-expiratory occlusion: a pilot study. Health Sci Rep. 2020;3:e190.

    Not in our library10.1002/hsr2.190

  52. 52.

    Myatra SN, Prabu NR, Divatia JV, Monnet X, Kulkarni AP, Teboul JL. The changes in pulse pressure variation or stroke volume variation after a "tidal volume challenge" reliably predict fluid responsiveness during low tidal volume ventilation. Crit Care Med. 2017;45:415-421.

    Not in our library10.1097/ccm.0000000000002183

  53. 53.

    Biais M, Larghi M, Henriot J, de Courson H, Sesay M, Nouette-Gaulain K. End-expiratory occlusion test predicts fluid responsiveness in patients with protective ventilation in the operating room. Anesth Analg. 2017;125:1889-1895.

    Not in our library10.1213/ane.0000000000002322

  54. 54.

    Alvarado Sanchez JI, Caicedo Ruiz JD, Diaztagle Fernandez JJ, Amaya Zuniga WF, Ospina-Tascon GA, Cruz Martinez LE. Predictors of fluid responsiveness in critically ill patients mechanically ventilated at low tidal volumes: systematic review and meta-analysis. Ann Intensive Care. 2021;11:28.

    Not in our library10.1186/s13613-021-00817-5

  55. 55.

    Silva S, Jozwiak M, Teboul JL, Persichini R, Richard C, Monnet X. End-expiratory occlusion test predicts preload responsiveness independently of positive end-expiratory pressure during acute respiratory distress syndrome. Crit Care Med. 2013;41:1692-1701.

    Not in our library10.1097/ccm.0b013e31828a2323

  56. 56.

    Yonis H, Bitker L, Aublanc M, Perinel RS, Riad Z, Lissonde F, et al. Change in cardiac output during Trendelenburg maneuver is a reliable predictor of fluid responsiveness in patients with acute respiratory distress syndrome in the prone position under protective ventilation. Crit Care. 2017;21:295.

    Not in our library10.1186/s13054-017-1881-0

  57. 57.

    Messina A, Montagnini C, Cammarota G, Giuliani F, Muratore L, Baggiani M, et al. Assessment of fluid responsiveness in prone neurosurgical patients undergoing protective ventilation: role of dynamic indices, tidal volume challenge, and end-expiratory occlusion test. Anesth Analg. 2020;130:752-761.

    Not in our library10.1213/ane.0000000000004494

  58. 58.

    Weil G, Motamed C, Monnet X, Eghiaian A, Le Maho AL. End-expiratory occlusion test to predict fluid responsiveness is not suitable for laparotomic surgery. Anesth Analg. 2020;130:151-158.

    Not in our library10.1213/ane.0000000000004205

  59. 59.

    Teboul JL, Monnet X, Chemla D, Michard F. Arterial pulse pressure variation with mechanical ventilation. Am J Respir Crit Care Med. 2019;199:22-31.

    Not in our library10.1164/rccm.201801-0088ci

  60. 60.

    Michard F, Chemla D, Teboul JL. Applicability of pulse pressure variation: how many shades of grey? Crit Care. 2015;19:144.

    Not in our library10.1186/s13054-015-0869-x

  61. 61.

    Mahjoub Y, Pila C, Friggeri A, Zogheib E, Lobjoie E, Tinturier F, et al. Assessing fluid responsiveness in critically ill patients: false-positive pulse pressure variation is detected by Doppler echocardiographic evaluation of the right ventricle. Crit Care Med. 2009;37:2570-2575.

    Not in our library10.1097/ccm.0b013e3181a380a3

  62. 62.

    Valenti E, Moller PW, Takala J, Berger D. Collapsibility of caval vessels and right ventricular afterload: decoupling of stroke volume variation from preload during mechanical ventilation. J Appl Physiol. 1985;2021(130):1562-1572.

    Not in our library10.1152/japplphysiol.01039.2020

  63. 63.

    Fot EV, Izotova NN, Smetkin AA, Kuzkov VV, Kirov MY. Dynamic tests to predict fluid responsiveness after off-pump coronary artery bypass grafting. J Cardiothorac Vasc Anesth. 2020;34:926-931.

    Not in our library10.1053/j.jvca.2019.09.013

  64. 64.

    Mallat J, Meddour M, Durville E, Lemyze M, Pepy F, Temime J, et al. Decrease in pulse pressure and stroke volume variations after mini-fluid challenge accurately predicts fluid responsiveness. Br J Anaesth. 2015;115:449-456.

    Not in our library10.1093/bja/aev222

  65. 65.

    Elsayed AI, Selim KA, Zaghla HE, Mowafy HE, Fakher MA. Comparison of changes in PPV using a tidal volume challenge with a passive leg raising test to predict fluid responsiveness in patients ventilated using low tidal volume. Indian J Crit Care Med. 2021;25:685-690.

    Not in our library10.5005/jp-journals-10071-23875

  66. 66.

    Messina A, Montagnini C, Cammarota G, De Rosa S, Giuliani F, Muratore L, et al. Tidal volume challenge to predict fluid responsiveness in the operating room: a prospective trial on neurosurgical patients undergoing protective ventilation. Eur J Anaesthesiol. 2019;36(8):581-593.

    Not in our library10.1097/eja.0000000000000998

  67. 67.

    Messina A, Montagnini C, Cammarota G, De Rosa S, Giuliani F, Muratore L, et al. Tidal volume challenge to predict fluid responsiveness in the operating room: an observational study. Eur J Anaesthesiol. 2019;36:583-591.

    Not in our library10.1097/eja.0000000000000998

  68. 68.

    Shi R, Monnet X, Teboul JL. Parameters of fluid responsiveness. Curr Opin Crit Care. 2020;26:319-326.

    Not in our library10.1097/mcc.0000000000000723

  69. 69.

    Zhang H, Zhang Q, Chen X, Wang X, Liu D, Chinese Critical Ultrasound Study G. Respiratory variations of inferior vena cava fail to predict fluid responsiveness in mechanically ventilated patients with isolated left ventricular dysfunction. Ann Intensive Care. 2019;9:113.

    Not in our library10.1186/s13613-019-0589-5

  70. 70.

    Das SK, Choupoo NS, Pradhan D, Saikia P, Monnet X. Diagnostic accuracy of inferior vena caval respiratory variation in detecting fluid unresponsiveness: a systematic review and meta-analysis. Eur J Anaesthesiol. 2018;35:831-839.

    Not in our library10.1097/eja.0000000000000841

  71. 71.

    Huang H, Shen Q, Liu Y, Xu H, Fang Y. Value of variation index of inferior vena cava diameter in predicting fluid responsiveness in patients with circulatory shock receiving mechanical ventilation: a systematic review and meta-analysis. Crit Care. 2018;22:204.

    Not in our library10.1186/s13054-018-2063-4

  72. 72.

    Vignon P, Repesse X, Begot E, Leger J, Jacob C, Bouferrache K, et al. Comparison of echocardiographic indices used to predict fluid responsiveness in ventilated patients. Am J Respir Crit Care Med. 2017;195:1022-1032.

    Not in our library10.1164/rccm.201604-0844oc

  73. 73.

    Magder S, Georgiadis G, Cheong T. Respiratory variations in right atrial pressure predict the response to fluid challenge. J Crit Care. 1992;1992:76-85.

    Not in our library10.1016/0883-9441(92)90032-3

  74. 74.

    Caplan M, Durand A, Bortolotti P, Colling D, Goutay J, Duburcq T, et al. Measurement site of inferior vena cava diameter affects the accuracy with which fluid responsiveness can be predicted in spontaneously breathing patients: a post hoc analysis of two prospective cohorts. Ann Intensive Care. 2020;10:168.

    Not in our library10.1186/s13613-020-00786-1

  75. 75.

    Caplan M, Howsam M, Favory R, Preau S. Predicting fluid responsiveness in non-intubated COVID-19 patients: two methods are better than one. Ann Intensive Care. 2021;11:34.

    Not in our library10.1186/s13613-021-00826-4

  76. 76.

    Michard F. Predicting fluid responsiveness in non-intubated COVID-19 patients. Ann Intensive Care. 2021;11:19.

    Not in our library10.1186/s13613-021-00813-9

  77. 77.

    Preau S, Bortolotti P, Colling D, Dewavrin F, Colas V, Voisin B, et al. Diagnostic accuracy of the inferior vena cava collapsibility to predict fluid responsiveness in spontaneously breathing patients with sepsis and acute circulatory failure. Crit Care Med. 2017;45:e290-e297.

    Not in our library10.1097/ccm.0000000000002090

  78. 78.

    Hofkens PJ, Verrijcken A, Merveille K, Neirynck S, Van Regenmortel N, De Laet I, et al. Common pitfalls and tips and tricks to get the most out of your transpulmonary thermodilution device: results of a survey and state-of-the-art review. Anaesthesiol Intensive Ther. 2015;47:89-116.

    Not in our library10.5603/ait.a2014.0068

  79. 79.

    Vincent JL, Cecconi M, De Backer D. The fluid challenge. Crit Care. 2020;24:703.

    Not in our library10.1186/s13054-020-03443-y

  80. 80.

    Muller L, Toumi M, Bousquet PJ, Riu-Poulenc B, Louart G, Candela D, et al. An increase in aortic blood flow after an infusion of 100 ml colloid over 1 minute can predict fluid responsiveness: the mini-fluid challenge study. Anesthesiology. 2011;115:541-547.

    Not in our library10.1097/aln.0b013e318229a500

  81. 81.

    Messina A, Lionetti G, Foti L, Bellotti E, Marcomini N, Cammarota G, et al. Mini fluid chAllenge aNd End-expiratory occlusion test to assess flUid responsiVEness in the opeRating room (MANEUVER study): a multicentre cohort study. Eur J Anaesthesiol. 2021;38:422-431.

    Not in our library10.1097/eja.0000000000001406

  82. 82.

    Pierrakos C, Velissaris D, Scolletta S, Heenen S, De Backer D, Vincent JL. Can changes in arterial pressure be used to detect changes in cardiac index during fluid challenge in patients with septic shock? Intensive Care Med. 2012;38:422-428.

    Not in our library10.1007/s00134-011-2457-0

  83. 83.

    Biais M, de Courson H, Lanchon R, Pereira B, Bardonneau G, Griton M, et al. Mini-fluid challenge of 100 ml of crystalloid predicts fluid responsiveness in the operating room. Anesthesiology. 2017;127:450-456.

    Not in our library10.1097/aln.0000000000001753

  84. 84.

    Vistisen ST, Scheeren TWL. Challenge of the mini-fluid challenge: filling twice without creating a self-fulfilling prophecy design. Anesthesiology. 2018;128:1043-1044.

    Not in our library10.1097/aln.0000000000002141

  85. 85.

    Enevoldsen J, Scheeren TWL, Berg JM, Vistisen ST. Existing fluid responsiveness studies using the mini-fluid challenge may be misleading: methodological considerations and simulations. Acta Anaesthesiol Scand. 2021;66(1):17-24.

    Not in our library10.1111/aas.13965

  86. 86.

    Biais M, Lanchon R, Sesay M, Le Gall L, Pereira B, Futier E, et al. Changes in stroke volume induced by lung recruitment maneuver predict fluid responsiveness in mechanically ventilated patients in the operating room. Anesthesiology. 2017;126:260-267.

    Not in our library10.1097/aln.0000000000001459

  87. 87.

    Kimura A, Suehiro K, Juri T, Fujimoto Y, Yoshida H, Tanaka K, et al. Hemodynamic changes via the lung recruitment maneuver can predict fluid responsiveness in stroke volume and arterial pressure during one-lung ventilation. Anesth Analg. 2021;133:44-52.

    Not in our library10.1213/ane.0000000000005375

  88. 88.

    De Broca B, Garnier J, Fischer MO, Archange T, Marc J, Abou-Arab O, et al. Stroke volume changes induced by a recruitment maneuver predict fluid responsiveness in patients with protective ventilation in the operating theater. Medicine (Baltimore). 2016;95:e4259.

    Not in our library10.1097/md.0000000000004259

  89. 89.

    de Courson H, Michard F, Chavignier C, Verchere E, Nouette-Gaulain K, Biais M. Do changes in perfusion index reflect changes in stroke volume during preload-modifying manoeuvres? J Clin Monit Comput. 2020;34:1193-1198.

    Not in our library10.1007/s10877-019-00445-2

  90. 90.

    Messina A, Colombo D, Barra FL, Cammarota G, De Mattei G, Longhini F, et al. Sigh maneuver to enhance assessment of fluid responsiveness during pressure support ventilation. Crit Care. 2019;23:31.

    Not in our library10.1186/s13054-018-2294-4

  91. 91.

    Preisman S, Kogan S, Berkenstadt H, Perel A. Predicting fluid responsiveness in patients undergoing cardiac surgery: functional haemodynamic parameters including the Respiratory Systolic Variation Test and static preload indicators. Br J Anaesth. 2005;95:746-755.

    Not in our library10.1093/bja/aei262

  92. 92.

    Luo JC, Su Y, Dong LL, Hou JY, Li X, Zhang Y, et al. Trendelenburg maneuver predicts fluid responsiveness in patients on veno-arterial extracorporeal membrane oxygenation. Ann Intensive Care. 2021;11:16.

    Not in our library10.1186/s13613-021-00811-x

  93. 93.

    Ma GG, Xu LY, Luo JC, Hou JY, Hao GW, Su Y, et al. Change in left ventricular velocity time integral during Trendelenburg maneuver predicts fluid responsiveness in cardiac surgical patients in the operating room. Quant Imaging Med Surg. 2021;11:3133-3145.

    Not in our library10.21037/qims-20-700

  94. 94.

    Monnet X, Teboul JL. My patient has received fluid. How to assess its efficacy and side effects? Ann Intensive Care. 2018;8:54.

    Not in our library10.1186/s13613-018-0400-z

  95. 95.

    Adda I, Lai C, Teboul JL, Guerin L, Gavelli F, Monnet X. Norepinephrine potentiates the efficacy of volume expansion on mean systemic pressure in septic shock. Crit Care. 2021;25:302.

    Not in our library10.1186/s13054-021-03711-5

  96. 96.

    Persichini R, Silva S, Teboul JL, Jozwiak M, Chemla D, Richard C, et al. Effects of norepinephrine on mean systemic pressure and venous return in human septic shock*. Crit Care Med. 2012;40:3146-3153.

    Not in our library10.1097/ccm.0b013e318260c6c3

  97. 97.

    Dres M, Teboul JL, Anguel N, Guerin L, Richard C, Monnet X. Passive leg raising performed before a spontaneous breathing trial predicts weaning-induced cardiac dysfunction. Intensive Care Med. 2015;41:487-494.

    Not in our library10.1007/s00134-015-3653-0

  98. 98.

    Monnet X, Julien F, Ait-Hamou N, Lequoy M, Gosset C, Jozwiak M, et al. Lactate and venoarterial carbon dioxide difference/arterial-venous oxygen difference ratio, but not central venous oxygen saturation, predict increase in oxygen consumption in fluid responders. Crit Care Med. 2013;41:1412-1420.

    Not in our library10.1097/ccm.0b013e318275cece

  99. 99.

    Bednarczyk JM, Fridfinnson JA, Kumar A, Blanchard L, Rabbani R, Bell D, et al. Incorporating dynamic assessment of fluid responsiveness into goal-directed therapy: a systematic review and meta-analysis. Crit Care Med. 2017;45:1538-1545.

    Not in our library10.1097/ccm.0000000000002554

  100. 100.
  101. 101.

    Dave C, Shen J, Chaudhuri D, Herritt B, Fernando SM, Reardon PM, et al. Dynamic assessment of fluid responsiveness in surgical ICU patients through stroke volume variation is associated with decreased length of stay and costs: a systematic review and meta-analysis. J Intensive Care Med. 2020;35:14-23.

    Not in our library10.1177/0885066618805410

  102. 102.

    Fellahi JL, Futier E, Vaisse C, Collange O, Huet O, Loriau J, et al. Perioperative hemodynamic optimization: from guidelines to implementation-an experts' opinion paper. Ann Intensive Care. 2021;11:58.

    Not in our library10.1186/s13613-021-00845-1

  103. 103.

    Messina A, Robba C, Calabro L, Zambelli D, Iannuzzi F, Molinari E, et al. Association between perioperative fluid administration and postoperative outcomes: a 20-year systematic review and a meta-analysis of randomized goal-directed trials in major visceral/noncardiac surgery. Crit Care. 2021;25:43.

    Not in our library10.1186/s13054-021-03464-1

  104. 104.

    Douglas IS, Alapat PM, Corl KA, Exline MC, Forni LG, Holder AL, et al. Fluid response evaluation in sepsis hypotension and shock: a randomized clinical trial. Chest. 2020;158:1431-1445.

    Not in our library10.1016/j.chest.2020.04.025

  105. 105.

    Chen C, Kollef MH. Targeted fluid minimization following initial resuscitation in septic shock: a pilot study. Chest. 2015;148:1462-1469.

    Not in our library10.1378/chest.15-1525

  106. 106.

    Richard JC, Bayle F, Bourdin G, Leray V, Debord S, Delannoy B, et al. Preload dependence indices to titrate volume expansion during septic shock: a randomized controlled trial. Crit Care. 2015;19:5.

    Not in our library10.1186/s13054-014-0734-3

  107. 107.

    Ehrman RR, Gallien JZ, Smith RK, Akers KG, Malik AN, Harrison NE, et al. Resuscitation guided by volume responsiveness does not reduce mortality in sepsis: a meta-analysis. Crit Care Explor. 2019;1:e0015.

    Not in our library10.1097/cce.0000000000000015

  108. 108.

    Azadian M, Win S, Abdipour A, Kim CK, Nguyen HB. Mortality benefit from the passive leg raise maneuver in guiding resuscitation of septic shock patients: a systematic review and meta-analysis of randomized trials. J Intensive Care Med. 2021.

    Not in our library10.1177/08850666211019713

  109. 109.

    Dubin A, Loudet C, Kanoore EV, Osatnik J, Rios F, Vasquez D, et al. Characteristics of resuscitation, and association between use of dynamic tests of fluid responsiveness and outcomes in septic patients: results of a multicenter prospective cohort study in Argentina. Ann Intensive Care. 2020;10:40.

    Not in our library10.1186/s13613-020-00659-7

  110. 110.

    Vincent JL, Sakr Y. Clinical trial design for unmet clinical needs: a spotlight on sepsis. Expert Rev Clin Pharmacol. 2019;12:893-900.

    Not in our library10.1080/17512433.2019.1643235

  111. 111.

    Cecconi M, Arulkumaran N, Kilic J, Ebm C, Rhodes A. Update on hemodynamic monitoring and management in septic patients. Minerva Anestesiol. 2014;80:701-711.

    Not in our library

  112. 112.

    Vincent JL, Singer M, Einav S, Moreno R, Wendon J, Teboul JL, et al. Equilibrating SSC guidelines with individualized care. Crit Care. 2021;25:397.

    Not in our library10.1186/s13054-021-03813-0

Cited by papers we hold 3

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.