Skip to content
naulon
Not checkedNot checked for notices yet.

Unstimulated whole saliva flow for diagnosis of primary Sjögren’s syndrome: time to revisit the threshold?

Valentin Lacombe, Carole Lacout, Pierre Lozac’h and 4 more

Arthritis Research & Therapy · 2020

doi:10.1186/s13075-020-2132-3 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

Background Unstimulated whole saliva (UWS) flow rate is one of the ACR/EULAR 2016 criteria for primary Sjögren’s syndrome (pSS). With a single threshold of ≤ 0.1 mL/min, UWS flow does not take into account the age- and sex-related physiological variations. Furthermore, it has a low sensitivity for the diagnosis of pSS (about 50%), contrary to the screening test for xerophthalmia, Schirmer’s test (sensitivity of about 70%). We aimed to identify UWS thresholds allowing better performances for a screening test for pSS comparable to Schirmer’s test, and considering age- and sex-related variations. Methods A prospective cohort of 185 patients with oral and/or ocular dryness was classified into 3 groups: men, women < 50 (< 50 years old), and women ≥ 50 (≥ 50 years old). The diagnostic performances of UWS flow rate in these groups were compared in terms of sensitivity, specificity, positive and negative predictive values, and ROC curves. The identification of thresholds that optimize diagnostic performances was carried out using Youden’s index. Results The diagnostic performances of UWS flow rate varied according to age and sex. UWS had poor diagnostic performances whatever the threshold in the women ≥ 50 group. The threshold of 0.2 mL/min had a sensitivity of ≥ 70% and a specificity of ≥ 50% in both men and women < 50 groups. In the whole population and compared to the current cutoff, a threshold of 0.2 mL/min increased sensitivity (+ 19.8%) and positive (+ 2.3%) and negative (+ 7.0%) predictive values, with a better specificity (65.2%) than Schirmer’s test. Conclusion For objective assessment of xerostomia, raising the threshold of the UWS flow rate to 0.2 mL/min would optimize its screening performances for pSS.

Abstract licence: CC BY-NC-ND

References37

    37 more references, whose wording the paper’s licence keeps private.

    Reads

    Read by people on this page

    None yet.

    Checked or read by AI through naulon

    None yet.

    A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

    Are you an author?

    Is this your paper?

    Claim it to add your note and be paid when agents cite it. Free.