Skip to content
naulon

No retraction, correction or concern found when last checked on Nov 1, 2026.

Pulse oximetry

Amal Jubran

Critical Care · 2015 · Review

doi:10.1186/s13054-015-0984-8

Abstract

Pulse oximetry is universally used for monitoring patients in the critical care setting. This article updates the review on pulse oximetry that was published in 1999 in Critical Care. A summary of the recently developed multiwavelength pulse oximeters and their ability in detecting dyshemoglobins is provided. The impact of the latest signal processing techniques and reflectance technology on improving the performance of pulse oximeters during motion artifact and low perfusion conditions is critically examined. Finally, data regarding the effect of pulse oximetry on patient outcome are discussed.

Shown for reading. Its publisher allows quoting it, not republishing it.

References 54

  1. 1.

    Jubran A. Pulse oximetry. Crit Care. 1999;3:R11-7.

    Not in our library10.1186/cc341

  2. 2.

    Wukitsch MW, Petterson MT, Tobler DR, Pologe JA. Pulse oximetry: analysis of theory, technology, and practice. J Clin Monit. 1988;4:290-301.

    Not in our library10.1007/bf01617328

  3. 3.

    Wouters PF, Gehring H, Meyfroidt G, Ponz L, Gil-Rodriguez J, Hornberger C, et al. Accuracy of pulse oximeters: the European multi-center trial. Anesth Analg. 2002;94(1 Suppl):S13-6.

    Not in our library

  4. 4.

    Webb RK, Ralston AC, Runciman WB. Potential errors in pulse oximetry, II. Effects of changes in saturation and signal quality. Anaesthesia. 1991;46:207-12.

    Not in our library10.1111/j.1365-2044.1991.tb09411.x

  5. 5.

    Van de Louw A, Cracco C, Cerf C, Harf A, Duvaldestin P, Lemaire F, et al. Accuracy of pulse oximetry in the intensive care unit. Intensive Care Med. 2001;27:1606-13.

    Not in our library10.1007/s001340101064

  6. 6.

    Jubran A, Tobin MJ. Reliability of pulse oximetry in titrating supplemental oxygen therapy in ventilator-dependent patients. Chest. 1990;97:1420-5.

    Not in our library10.1378/chest.97.6.1420

  7. 7.

    Pulse oximeters. Health Devices. 1989;18:185–99, 206–19, 222–30.

    Not in our library

  8. 8.

    Perkins GD, McAuley DF, Giles S, Routledge H, Gao F. Do changes in pulse oximeter oxygen saturation predict equivalent changes in arterial oxygen saturation? Crit Care. 2003;7:R67.

    Not in our library10.1186/cc2339

  9. 9.

    Clayton DG, Webb RK, Ralston AC, Duthie D, Runciman WB. Pulse oximeter probes. A comparison between finger, nose, ear and forehead probes under conditions of poor perfusion. Anaesthesia. 1991;46:260-5.

    Not in our library10.1111/j.1365-2044.1991.tb11492.x

  10. 10.

    Branson RD, Mannheimer PD. Forehead oximetry in critically ill patients: the case for a new monitoring site. Respir Care Clin N Am. 2004;10:359-67.

    Not in our library10.1016/j.rcc.2004.04.003

  11. 11.

    Fernandez M, Burns K, Calhoun B, George S, Martin B, Weaver C. Evaluation of a new pulse oximeter sensor. Am J Crit Care. 2007;16:146-52.

    Not in our library

  12. 12.

    Schallom L, Sona C, McSweeney M, Mazuski J. Comparison of forehead and digit oximetry in surgical/trauma patients at risk for decreased peripheral perfusion. Heart Lung. 2007;36:188-94.

    Not in our library10.1016/j.hrtlng.2006.07.007

  13. 13.

    Hodgson CL, Tuxen DV, Holland AE, Keating JL. Comparison of forehead Max-Fast pulse oximetry sensor with finger sensor at high positive end-expiratory pressure in adult patients with acute respiratory distress syndrome. Anaesth Intensive Care. 2009;37:953-60.

    Not in our library10.1177/0310057x0903700620

  14. 14.

    Young D, Jewkes C, Spittal M, Blogg C, Weissman J, Gradwell D. Response time of pulse oximeters assessed using acute decompression. Anesth Analg. 1992;74:189-95.

    Not in our library10.1213/00000539-199202000-00003

  15. 15.

    Jubran A, Tobin MJ. Pulse oximetry. Principles and Practice of Intensive Care Monitoring. 1998;261-87.

    Not in our library

  16. 16.

    Choi SJ, Ahn HJ, Yang MK, Kim CS, Sim WS, Kim JA, et al. Comparison of desaturation and resaturation response times between transmission and reflectance pulse oximeters. Acta Anaesthesiol Scand. 2010;54:212-7.

    Not in our library10.1111/j.1399-6576.2009.02101.x

  17. 17.

    MacLeod DB, Cortinez LI, Keifer JC, Cameron D, Wright DR, White WD, et al. The desaturation response time of finger pulse oximeters during mild hypothermia. Anaesthesia. 2005;60:65-71.

    Not in our library10.1111/j.1365-2044.2004.04033.x

  18. 18.

    Ralston AC, Webb RK, Runciman WB. Potential errors in pulse oximetry, I. Pulse oximeter evaluation. Anaesthesia. 1991;46:202-6.

    Not in our library10.1111/j.1365-2044.1991.tb09410.x

  19. 19.

    Buckley RG, Aks SE, Eshom JL, Rydman R, Schaider J, Shayne P. The pulse oximetry gap in carbon monoxide intoxication. Ann Emerg Med. 1994;24:252-5.

    Not in our library10.1016/s0196-0644(94)70137-7

  20. 20.

    Barker SJ, Curry J, Redford D, Morgan S. Measurement of carboxyhemoglobin and methemoglobin by pulse oximetry: a human volunteer study. Anesthesiology. 2006;105:892-7.

    Not in our library10.1097/00000542-200611000-00008

  21. 21.

    Feiner JR, Rollins MD, Sall JW, Eilers H, Au P, Bickler PE. Accuracy of carboxyhemoglobin detection by pulse CO-oximetry during hypoxemia. Anesth Analg. 2013;117:847-58.

    Not in our library10.1213/ane.0b013e31828610a0

  22. 22.

    Sebbane M, Claret PG, Mercier G, Lefebvre S, Thery R, Dumont R, et al. Emergency department management of suspected carbon monoxide poisoning: role of pulse CO-oximetry. Respir Care. 2013;58:1614-20.

    Not in our library10.4187/respcare.02313

  23. 23.

    Touger M, Birnbaum A, Wang J, Chou K, Pearson D, Bijur P. Performance of the RAD-57 pulse CO-oximeter compared with standard laboratory carboxyhemoglobin measurement. Ann Emerg Med. 2010;56:382-8.

    Not in our library10.1016/j.annemergmed.2010.03.041

  24. 24.

    Maisel WH, Lewis RJ. Noninvasive measurement of carboxyhemoglobin: how accurate is accurate enough? Ann Emerg Med. 2010;56:389-91.

    Not in our library10.1016/j.annemergmed.2010.05.025

  25. 25.

    Saito S, Fukura H, Shimada H, Fujita T. Prolonged interference of blue dye ‘patent blue’ with pulse oximetry readings. Acta Anaesthesiol Scand. 1995;39:268-9.

    Not in our library10.1111/j.1399-6576.1995.tb04055.x

  26. 26.

    Comber JT, Lopez BL. Evaluation of pulse oximetry in sickle cell anemia patients presenting to the emergency department in acute vasoocclusive crisis. Am J Emerg Med. 1996;14:16-8.

    Not in our library10.1016/s0735-6757(96)90005-4

  27. 27.

    Fluck RR, Schroeder C, Frani G, Kropf B, Engbretson B. Does ambient light affect the accuracy of pulse oximetry? Respir Care. 2003;48:677-80.

    Not in our library

  28. 28.

    Cote CJ, Goldstein EA, Fuchsman WH, Hoaglin DC. The effect of nail polish on pulse oximetry. Anesth Analg. 1988;67:683-6.

    Not in our library

  29. 29.

    Hinkelbein J, Genzwuerker HV, Sogl R, Fiedler F. Effect of nail polish on oxygen saturation determined by pulse oximetry in critically ill patients. Resuscitation. 2007;72:82-91.

    Not in our library10.1016/j.resuscitation.2006.06.024

  30. 30.

    Reich DL, Timcenko A, Bodian CA, Kraidin J, Hofman J, DePerio M, et al. Predictors of pulse oximetry data failure. Anesthesiology. 1996;84:859-64.

    Not in our library10.1097/00000542-199604000-00013

  31. 31.

    Moller JT, Pedersen T, Rasmussen LS, Jensen PF, Pedersen BD, Ravlo O, et al. Randomized evaluation of pulse oximetry in 20,802 patients: I. Design, demography, pulse oximetry failure rate, and overall complication rate. Anesthesiology. 1993;78:436-44.

    Not in our library10.1097/00000542-199303000-00006

  32. 32.

    Runciman WB, Webb RK, Barker L, Currie M. The Australian Incident Monitoring Study. The pulse oximeter: applications and limitations - an analysis of 2000 incident reports. Anaesth Intensive Care. 1993;21:543-50.

    Not in our library10.1177/0310057x9302100509

  33. 33.

    Rheineck-Leyssius AT, Kalkman CJ. Influence of pulse oximeter lower alarm limit on the incidence of hypoxaemia in the recovery room. Br J Anaesth. 1997;79:460-4.

    Not in our library10.1093/bja/79.4.460

  34. 34.

    Barker SJ. ‘Motion-resistant’ pulse oximetry: a comparison of new and old models. Anesth Analg. 2002;95:967-72.

    Not in our library10.1097/00000539-200210000-00033

  35. 35.

    Petterson MT, Begnoche VL, Graybeal JM. The effect of motion on pulse oximetry and its clinical significance. Anesth Analg. 2007;105(6 Suppl):S78-84.

    Not in our library10.1213/01.ane.0000278134.47777.a5

  36. 36.

    Next-generation pulse oximetry. Health Devices. 2003;32:49–103.

    Not in our library

  37. 37.

    Barker SJ, Shah NK. The effects of motion on the performance of pulse oximeters in volunteers (revised publication). Anesthesiology. 1997;86:101-8.

    Not in our library10.1097/00000542-199701000-00014

  38. 38.

    Dumas C, Wahr JA, Tremper KK. Clinical evaluation of a prototype motion artifact resistant pulse oximeter in the recovery room. Anesth Analg. 1996;83:269-72.

    Not in our library10.1097/00000539-199608000-00012

  39. 39.

    Pollard V, Prough DS. Signal extraction technology: a better mousetrap? Anesth Analg. 1996;83:213-4.

    Not in our library10.1097/00000539-199608000-00002

  40. 40.

    Giuliano KK, Liu LM. Knowledge of pulse oximetry among critical care nurses. Dimens Crit Care Nurs. 2006;25:44-9.

    Not in our library10.1097/00003465-200601000-00013

All 54 references

Cited by papers we hold 2

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.