Skip to content
naulon
Not checkedNot checked for notices yet.

Accuracy of intraoral scans in the mixed dentition: a prospective non-randomized comparative clinical trial

Konrad Liczmanski, Thomas Stamm, Cristina Sauerland and 1 more

Head & Face Medicine · 2020

doi:10.1186/s13005-020-00222-6 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

Objective In-vivo accuracy of intraoral scans of complete mixed dentitions of patients in active treatment have not yet been investigated. The aim was to test the hypothesis that dimensional differences between intraoral scans and conventional alginate impressions in the mixed dentition are clinically irrelevant. Methods Trial design: Prospective non-randomized comparative clinical trial. Based on sample size calculation 44 evaluable mixed dentition jaws of patients in active orthodontic treatment were included. Each patient received an alginate impression following an intraoral scan (TRIOS® Ortho). Plaster cast was fabricated and scanned with an external scanner (ATOS-SO®). Both STL datasets were analyzed with the 3D inspection and mesh processing software GOM Inspect®. Statistical analysis comprised sample size calculation, t-test as well as nonparametric tests. Results The absolute mean difference between digital plaster casts and intraoral scans is 0.022 mm ± 0.027 mm (median 0.015 mm). The obtained measurements are in the range of comparable studies on full arch permanent dentitions. Gender, the size of the jaw represented by the dentition stage and upper respectively lower jaw, as well the malocclusion have no effect on the total deviations between digital plaster casts and intraoral scans. Detectable impression errors were bubbles in fissures and marginal ridges as well as incomplete alginate flow and detachment from the tray. Detectable scanning errors were incomplete distal surface of the most distal molar. Conclusion Dimensional differences between intraoral scans and conventional alginate impressions in the mixed dentition are clinically irrelevant for orthodontic purposes. In all clinical situations of active treatment in the mixed dentition, the intraoral scans are more detailed and less error-prone.

Abstract licence: CC BY-NC-ND

References20

    20 more references, whose wording the paper’s licence keeps private.

    Reads

    Read by people on this page

    None yet.

    Checked or read by AI through naulon

    None yet.

    A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

    Are you an author?

    Is this your paper?

    Claim it to add your note and be paid when agents cite it. Free.