Plane wave imaging combined with eigenspace-based minimum variance beamforming using a ring array in ultrasound computed tomography
Xinming Jiang, Yang Xiao, Yuanyuan Wang and 2 more
BioMedical Engineering OnLine · 2019
doi:10.1186/s12938-019-0629-2 (opens in a new tab)
We email you when a new notice or a question about this paper appears.
Abstract
Abstract Background Ultrasound computed tomography (USCT) is usually realized with a ring array. It can provide better imaging performance and more tissue information by emitting and receiving the ultrasound signal in different directions simultaneously. However, USCT imaging is usually applied with the synthetic aperture (SA) emission method, which leads to a long scanning time with a large number of elements on the ring array. The echo image can provide the structural information, and has a higher resolution than maps of other parameters in USCT. Hence, we proposed plane wave (PW) imaging for ring array to acquire the echo wave and reduce the scanning time considerably. Results In this paper, an emitting and receiving process was proposed to realize plane wave imaging with a ring array. With the proposed scanning method, the number of emission events can be reduced greatly. A beamforming method based on the eigenspace-based minimum variance (ESBMV) was also combined with the scanning method. With ESBMV beamformer, the resolution and contrast ratio of reconstruction result can be maintained or even improved under a fewer-emissions condition. We validated the method using both computer simulations with Field II and phantom experiments with a ring array of 512 elements. The Verasonics® system was used to transmit and receive the ultrasound signal in the phantom experiments. Conclusions According to the results of the experiments, the imaging results will have a better contrast ratio with a higher emitting energy. Additionally, the scanning time with the proposed method can be only one-tenth of that with the SA emission method, while the echo imaging performance still remains at a similar level or even better.
Abstract licence: CC BY-NC-ND
References21
21 more references, whose wording the paper’s licence keeps private.
Reads
Read by people on this page
None yet.
Checked or read by AI through naulon
None yet.
A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.
Are you an author?
Is this your paper?
Claim it to add your note and be paid when agents cite it. Free.