Not checkedNot checked for notices yet.
Surfactant Protein A in particles in exhaled air (PExA), bronchial lavage and bronchial wash - a methodological comparison
Annelie F. Behndig, Ekaterina Mirgorodskaya, Anders Blomberg and 1 more
Respiratory Research · 2019
doi:10.1186/s12931-019-1172-1 (opens in a new tab)
We email you when a new notice or a question about this paper appears.
Abstract
Introduction At present, there are few methods available for monitoring respiratory diseases affecting distal airways. Bronchoscopy is the golden standard for sampling the lower airways. The recently developed method for collecting non-volatile material from exhaled air – PExA (Particles in Exhaled air) is a promising new tool, but no direct comparison between the two methods has yet been performed. The aim of the present study was to compare sampling using PExA with bronchial wash (BW) representing the larger more proximal airways and broncho-alveolar lavage (BAL) representing the distal airways. Methods 15 healthy non-smoking subjects (7 female/8 male), age 28 ± 4 years, with normal lung function were included in the study. PExA-sampling (2 × 250 ng particles) and bronchoscopy with BW (2 × 20 ml) and BAL (3 × 60 ml sterile saline) was performed. Albumin and Surfactant Protein A (SP-A) were analyzed with ELISA, and analyses of correlation were performed. Results A significant association was found between BAL-fluid albumin and PExA-albumin (r s :0.65 p = 0.01). There was also an association between SP-A in PExA and BAL, when corrected for albumin concentration (r s :0.61, p = 0.015). When correlating concentrations of albumin and SP-A in bronchial wash and PExA respectively, no associations were found. Conclusions This is the first direct comparison between the bronchoscopy-based BW/BAL-fluids and material collected using the PExA methodology. Both albumin and albumin-corrected SP-A concentrations were significantly associated between BAL and PExA, however, no such association was found in either marker between BW and PExA. These results indicate that the PExA method samples the distal airways. PExA is thus considered a new promising non-invasive assessment for monitoring of the distal airways.
Abstract licence: CC BY-NC-ND
References17
17 more references, whose wording the paper’s licence keeps private.
Reads
Read by people on this page
None yet.
Checked or read by AI through naulon
None yet.
A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.
Are you an author?
Is this your paper?
Claim it to add your note and be paid when agents cite it. Free.