A European inter-laboratory trial to evaluate the performance of three serological methods for diagnosis of Mycoplasma bovis infection in cattle using latent class analysis
Anna-Maria Andersson, Anna Aspán, Henk J. Wisselink and 8 more
BMC Veterinary Research · 2019
doi:10.1186/s12917-019-2117-0 (opens in a new tab)
We email you when a new notice or a question about this paper appears.
Abstract
Background Mycoplasma bovis ( M. bovis ) is an emerging bovine pathogen, leading to significant economic losses in the livestock industry worldwide. Infection can result in a variety of clinical signs, such as arthritis, pneumonia, mastitis and keratoconjunctivitis, none of which are M. bovis -specific. Laboratory diagnosis is therefore important. Serological tests to detect M. bovis antibodies is considered an effective indicator of infection in a herd and often used as a herd test. Combined with clinical judgement, it can also be used to implement control strategies and/or to estimate the disease prevalence within a country. However, due to lack of harmonisation of approaches to testing, and serological tests used by different laboratories, comparisons of prevalence data between countries is often difficult. A network of researchers from six European countries designed and participated in an inter-laboratory trial, with the aim of evaluating the sensitivity ( Se ) and specificity (Sp) of two commercially available ELISA tests (ID Screen® ELISA (IDvet) and BIO K302 ELISA (BIO-X Diagnostics)) for diagnosis of M. bovis infection. Each laboratory received a blinded panel of bovine sera and tested independently, according to manufacturer’s instructions. Western blot analyses (WB) performed by one of the participating laboratories was used as a third diagnostic test in the statistical evaluation of Se and Sp values using latent class analysis. Results The Se of WB, the ID Screen® ELISA and the BIO K302 ELISA were determined to be 91.8, 93.5 and 49.1% respectively, and corresponding Sp of the three tests were 99.6, 98.6 and 89.6%, respectively. Conclusions The present study is, to our knowledge, the first to present an inter-laboratory comparison of the BIO K302 ELISA and the ID Screen® ELISA. Based on our results, the ID Screen® ELISA showed high consistency with WB and performed with higher precision and accuracy than the BIO K302 ELISA.
Abstract licence: CC BY-NC-ND
References40
40 more references, whose wording the paper’s licence keeps private.
Reads
Read by people on this page
None yet.
Checked or read by AI through naulon
None yet.
A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.
Are you an author?
Is this your paper?
Claim it to add your note and be paid when agents cite it. Free.