Skip to content
naulon
Not checkedNot checked for notices yet.

Reconstruction of vertical alveolar ridge deficiencies utilizing a high-density polytetrafluoroethylene membrane /clinical impact of flap dehiscence on treatment outcomes: case series/

Daniel Palkovics, Fanni Bolya-Orosz, Csaba Pinter and 2 more

BMC Oral Health · 2022

doi:10.1186/s12903-022-02513-7 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

Objectives The aim of this study was to evaluate the effects of membrane exposure during vertical ridge augmentation (VRA) utilizing guided bone regeneration with a dense polytetrafluoroethylene (d-PTFE) membrane and a tent-pole space maintaining approach by registering radiographic volumetric, linear and morphological changes. Methods In 8 cases alveolar ridge defects were accessed utilizing a split-thickness flap design. Following flap elevation VRA was performed with tent-pole space maintaining approach utilizing the combination of a non-reinforced d-PTFE membrane and a composite graft (1:1 ratio of autogenous bone chips and bovine derived xenografts). Three-dimensional radiographic evaluation of hard tissue changes was carried out with the sequence of cone-beam computed tomography (CBCT) image segmentation, spatial registration and 3D subtraction analysis. Results Class I or class II membrane exposure was observed in four cases. Average hard tissue gain was found to be 0.70 cm 3 ± 0.31 cm 3 and 0.82 cm 3 ± 0.40 cm 3 with and without membrane exposure resulting in a 17% difference. Vertical hard tissue gain averaged 4.06 mm ± 0.56 mm and 3.55 mm ± 0.43 mm in case of submerged and open healing, respectively. Difference in this regard was 14% between the two groups. Horizontal ridge width at 9-month follow-up was 5.89 mm ± 0.51 mm and 5.61 mm ± 1.21 mm with and without a membrane exposure respectively, resulting in a 5% difference. Conclusions With the help of the currently reported 3D radiographic evaluation method, it can be concluded that exposure of the new-generation d-PTFE membrane had less negative impact on clinical results compared to literature data reporting on expanded polytetrafluoroethylene membranes.

Abstract licence: CC BY-NC-ND

References37

  1. 25.

36 more references, whose wording the paper’s licence keeps private.

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.