Needle Adjustment Free (NAF) running suture technique (PAN suture) in laparoscopic partial nephrectomy
Jun-wei Pan, Xiang Zhang, Xing-wei Jin and 9 more
BMC Surgery · 2021
doi:10.1186/s12893-021-01112-7 (opens in a new tab)
We email you when a new notice or a question about this paper appears.
Abstract
Abstract Background It is proposed a new running suture technique called Needle Adjustment Free (NAF) technique, or PAN suture. The efficiency and the safety were evaluated in laparoscopic partial nephrectomy. Methods This new running suture technique avoids the Needle Adjustment method used in traditional techniques. The new continuous suture technique (11 patients) was compared with the traditional continuous suture method (33 patients) used in both transperitoneal and retroperitoneal laparoscopic partial nephrectomy (LPN) in terms of suture time (ST), warm ischemia time (WIT), blood loss (BL), open conversion rate and post-op discharge time, post-op bleeding, post-op DVT, ΔGFR (affected side, 3 months post-op). Differences were considered significant when P < 0.05. Results ST in the PAN suture group was 30.37 ± 16.39 min, which was significant shorter (P = 0.0011) than in the traditional technique group which was 13.68 ± 3.33 min. WIT in the traditional technique group was 28.73 ± 7.89 min, while in the PAN suture group was 20.64 ± 5.04 min, P = 0.0028. The BL in entirety in the traditional technique group was 141.56 ± 155.23 mL, and in the PAN suture group was 43.18 ± 31.17 mL (P = 0.0017). BL in patients without massive bleeding in the traditional technique group was significantly greater than in the PAN suture group at 101.03 ± 68.73 mL versus 43.18 ± 31.17 mL (P = 0.0008). The open conversion rate was 0 % in both groups. There was no significant difference between the two groups in postoperative discharge time, post-op bleeding, post-op DVT, ΔGFR (affected side, 3 months post-op). Conclusions The NAF running suture technique, or PAN suture, leading to less ST, WIT and BL, which was shown to be more effective and safer than the traditional technique used for LPN. A further expanded research with larger sample size is needed.
Abstract licence: CC BY-NC-ND
Reads
Read by people on this page
None yet.
Checked or read by AI through naulon
None yet.
A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.
Are you an author?
Is this your paper?
Claim it to add your note and be paid when agents cite it. Free.