Skip to content
naulon
Not checkedNot checked for notices yet.

Excellent clinical and radiological outcome following locking compression plate fixation of displaced medial clavicle fractures

Markus Wurm, Sebastian Siebenlist, Michael Zyskowski and 4 more

BMC Musculoskeletal Disorders · 2021

doi:10.1186/s12891-021-04775-8 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

Abstract Background Treatment of medial clavicle fractures is still controversially discussed in the community of upper extremity surgeons. An increasing number of symptomatic non-unions following conservative treatment of displaced fractures led to the development of various surgical approaches. Aim of this study was to evaluate the clinical and radiological outcome following operative treatment of displaced medial end clavicle fractures. Methods Patients who presented with a displaced fracture of the medial clavicle between September 2012 and December 2019 were retrospectively enrolled in this study. All patients were operatively treated with open reduction and internal fixation (ORIF) using an anatomically precontoured locking compression plate (LCP) originally designed for the lateral clavicle (Synthes®, Umkirch, Germany). Functional outcome was recorded using the American Shoulder and Elbow Surgeons (ASES) Score, the Munich Shoulder Questionnaire (MSQ), Shoulder Pain and Disability Index (SPADI) and Constant Score. Results Overall 18 patients with a mean age of 54.5 ± 23.5 years suffering from a displaced fracture of the medial clavicle were identified. The mean follow-up was 40.9 ± 26.2 months. The mean ASES accounted for 88.3 ± 20.8 points, the mean MSQ was 83.1 ± 21.7 points, the mean SPADI was 85.6 ± 22.5 and a mean normative age- and sex-specific Constant Score of 77.5 ± 19.1 points resulted. No minor or major complications were observed. Radiologic fracture consolidation was achieved in all patients after a mean of 6.4 months. Conclusion Surgical treatment of displaced medial clavicle fractures using an anatomically precontoured locking plate originally designed for the lateral clavicle led to very good to excellent clinical and functional results. Trial registration No: DRKS00024813, retrospectively registered 19.03.2021 ( www.drks.de ).

Abstract licence: CC BY-NC-ND

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.