Skip to content
naulon

Not checkedNot checked for notices yet.

Acromioclavicular joint dislocation treated with Bosworth screw and additional K-wiring: results after 7.8 years – still an adequate procedure?

Thomas M. Tiefenboeck, Domenik Popp, Sandra Boesmueller and 6 more

BMC Musculoskeletal Disorders · 2017

doi:10.1186/s12891-017-1692-0 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

Abstract Background The acromioclavicular (AC) joint dislocation is a major reason for shoulder instability. Different concepts of treatment and surgical methods are described in the literature. Thus, the purpose of this study was to present our data of long-term follow-up of patients having undergone treatment of acromioclavicular (AC) joint dislocation using the Bosworth Screw with additional K-wiring. Methods This study was conducted as a retrospective single centre data analysis. All patients treated operatively for AC joint dislocation with a Bosworth screw and additional K-wire fixation at our Department were asked to participate in this study. Results The study population consisted of 22 patients, 20 male and 2 female, with a mean age of 40 years ±15.6 years. Three grade-II lesions, 13 grade-III lesions, four grade-IV lesions and two grade-V lesions according to the Rockwood classification were found. The overall mean clinical outcome at the latest follow up was: Constant 95, DASH 6.4, ASES 94.6, SST 99.02, UCLA 33.1, ACJI 91.82 and VAS 0.29 – representing a good-to-excellent long-term outcome in all patients after at least 2 years follow-up (range; 2 - 19 years). Overall, 19 patients (86%) reported to be very satisfied with the achieved result, 15 patients (68%) reported to be able to participate in every sports activity and 16 patients (73%) reported to be able to perform their daily work without limitations. Overall, complications occurred in three patients (14%). Only one patient remained unsatisfied with the achieved result. Conclusion Summarizing, our reported results showed that surgical fixation of acute AC joint dislocation with a Bosworth screw and additional K-wire fixation leads to good-to-excellent functional outcome and highly satisfactory results in the majority of patients. Despite its complications, in accordance with our results, Bosworth screw fixation with additional K-wiring in AC joint dislocation represents an adequate surgical procedure. Level of Evidence: Level IV, retrospective study.

Abstract licence: CC BY-NC-ND

References31

    31 more references, whose wording the paper’s licence keeps private.

    Reads

    Read by people on this page

    None yet.

    Checked or read by AI through naulon

    None yet.

    A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

    Are you an author?

    Is this your paper?

    Claim it to add your note and be paid when agents cite it. Free.