Skip to content
naulon

Not checkedNot checked for notices yet.

Comparative clinical accuracy analysis of the newly developed ZZ IOL and four existing IOL formulas for post-corneal refractive surgery eyes

Jun Zhang, Jie Shao, Li Zheng and 2 more

BMC Ophthalmology · 2021

doi:10.1186/s12886-021-01991-7 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

Abstract Background Intraocular lens (IOL) calculation using traditional formulas for post-corneal refractive surgery eyes can yield inaccurate results. This study aimed to compare the clinical accuracy of the newly developed Zhang & Zheng (ZZ) formula with previously reported IOL formulas. Study design Retrospective study. Methods Post-corneal refractive surgery eyes were assessed for IOL power using the ZZ, Haigis-L, Shammas, Barrett True-K (no history), and ray tracing (C.S.O Sirius) IOL formulas, and their accuracy was compared. No pre-refractive surgery information was used in the calculations. Results This study included 38 eyes in 26 patients. ZZ IOL yielded a lower arithmetic IOL prediction error (PE) compared with ray tracing (P = 0.04), whereas the other formulas had values like that of ZZ IOL (P > 0.05). The arithmetic IOL PE for the ZZ IOL formula was not significantly different from zero (P = 0.96). ZZ IOL yielded a lower absolute IOL PE compared with Shammas (P < 0.01), Haigis-L (P = 0.02), Barrett true K (P = 0.03), and ray tracing (P < 0.01). The variance of the mean arithmetic IOL PE for ZZ IOL was significantly smaller than those of Shammas (P < 0.01), Haigis-L (P = 0.03), Barrett True K (P = 0.02), and ray tracing (P < 0.01). The percentages of eyes within ± 0.5 D of the target refraction with the ZZ IOL, Shammas, Haigis-L, Barrett True-K, and ray-tracing formulas were 86.8 %, 45.5 %, 66.7 %, 73.7 %, and 50.0 %, respectively (P < 0.05 for Shammas and ray tracing vs. ZZ IOL). Conclusions The ZZ IOL formula might offer superior outcomes for IOL power calculation for post-corneal refractive surgery eyes without prior refractive data.

Abstract licence: CC BY-NC-ND

References37

    37 more references, whose wording the paper’s licence keeps private.

    Reads

    Read by people on this page

    None yet.

    Checked or read by AI through naulon

    None yet.

    A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

    Are you an author?

    Is this your paper?

    Claim it to add your note and be paid when agents cite it. Free.