Skip to content
naulon

Not checkedNot checked for notices yet.

Dosimetric analysis of radiation-induced brainstem necrosis for nasopharyngeal carcinoma treated with IMRT

Xigang Fan, Yecai Huang, Peng Xu and 5 more

BMC Cancer · 2022

doi:10.1186/s12885-022-09213-z (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

Background Radiation-induced brainstem necrosis (RIBN) is a late life-threatening complication that can appear after treatment in patients with nasopharyngeal carcinoma (NPC). However, the relationship between RIBN and radiation dose is not still well-defined. Methods During January 2013 and December 2017, a total of 1063 patients with NPC were treated at Sichuan cancer hospital with IMRT. A total of 479 patients were eligible for dosimetric analysis. Dosimetric parameters of the RIBN, D max (the maximum dose), D 0.1c (maximum average dose delivered to a 0.1-cc volume), D 1cc , D 2cc , D 3cc , D 5cc , D 10cc and D mean (mean does) were evaluated and recorded. ROC curve was used to analyze the area under curve (AUC) and cutoff points. Logistic regression for screening dose-volume parameter and logistic dose response model were used to predict the incidence of brainstem necrosis. Results Among the 479 patients with NPC, 6 patients were diagnosed with RIBN, the incidence of RIBN was 1.25% (6/479), and the median time to RIBN after treatment was 28.5 months (range 18–48 months). The dose of the brainstem in patients with RIBN were higher than that in patients without necrosis. ROC curve showed that the area under the curve (AUC) of D max was the largest (0.987). Moreover, logistic stepwise regression indicated that D max was the most important dose factor. The RIBN incidence at 5% over 5 years (TD 5/5 ) and 50% incidence over 5 years (TD 50/5 ) was 69.59 Gy and76.45 Gy, respectively. Conclusions Brainstem necrosis is associated with high dose irritation. D max is the most significant predictive dosimetric factor for RIBN. D max of brainstem should be considered as the dose limitation parameter. We suggest that the limitation dose for brainstem was D max < 69.59 Gy.

Abstract licence: CC BY-NC-ND

References30

  1. 12.
  2. 30.

28 more references, whose wording the paper’s licence keeps private.

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.