Skip to content
naulon
Not checkedNot checked for notices yet.

Assessment of low-dose paranasal sinus CT imaging using a new deep learning image reconstruction technique in children compared to adaptive statistical iterative reconstruction V (ASiR-V)

Yang Li, Xia Liu, Xun-hui Zhuang and 2 more

BMC Medical Imaging · 2022

doi:10.1186/s12880-022-00834-1 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

Abstract Purpose To compare the effects of deep learning image reconstruction (DLIR) and adaptive statistical iterative reconstruction V (ASiR-V) on image quality in low-dose computed tomography (CT) of paranasal sinuses in children. Methods Low-dose CT scans of the paranasal sinuses in 25 pediatric patients were retrospectively evaluated. The raw data were reconstructed with three levels of DLIR (high, H; medium, M; and low, L), filtered back projection (FBP), and ASiR-V (30% and 50%). Image noise was measured in both soft tissue and bone windows, and the signal-to-noise ratios (SNRs) and contrast-to-noise ratios (CNRs) of the images were calculated. Subjective image quality at the ethmoid sinus and nasal cavity levels of the six groups of reconstructed images was assessed by two doctors using a five-point Likert scale in a double-blind manner. Results The patients’ mean dose-length product and effective dose were 36.65 ± 2.44 mGy·cm and 0.17 ± 0.03 mSv, respectively. (1) Objective evaluation: 1. Soft tissue window: The difference among groups in each parameter was significant (P < 0.05). Pairwise comparisons showed that the H group’ s parameters were significantly better (P < 0.05) than those of the 50% post-ASiR-V group. 2. Bone window: No significant between-group differences were found in the noise of the petrous portion of the temporal bone or its SNR or in the noise of the pterygoid processes of the sphenoids or their SNRs (P > 0.05). Significant differences were observed in the background noise and CNR (P < 0.05). As the DLIR intensity increased, image noise decreased and the CNR improved. The H group exhibited the best image quality. (2) Subjective evaluation: Scores for images of the ethmoid sinuses were not significantly different among groups (P > 0.05). Scores for images of the nasal cavity were significantly different among groups (P < 0.05) and were ranked in descending order as follows: H, M, L, 50% post-ASiR-V, 30% post-ASiR-V, and FBP. Conclusion DLIR was superior to FBP and post-ASiR-V in low-dose CT scans of pediatric paranasal sinuses. At high intensity (H), DLIR provided the best reconstruction effects.

Abstract licence: CC BY-NC-ND

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.