Not checkedNot checked for notices yet.
Is MRCP necessary to diagnose pancreas divisum?
Nino Bogveradze, Felix Hasse, Philipp Mayer and 5 more
BMC Medical Imaging · 2019
doi:10.1186/s12880-019-0329-1 (opens in a new tab)
We email you when a new notice or a question about this paper appears.
Abstract
Abstract Background The purpose of this study is to compare the performance of three-dimensional magnetic resonance cholangiopancreatography (3D-MRCP) with non-MRCP T2-weighted magnetic resonance imaging (MRI) sequences for diagnosis of pancreas divisum (PD). Methods This is a retrospective study of 342 consecutive patients with abdominal MRI including 3D-MRCP. 3D-MRCP was a coronal respiration-navigated T2-weighted sequence with 1.5 mm slice thickness. Non-MRCP T2-weighted sequences were (1) a coronal inversion recovery sequence (TIRM) with 6 mm slice thickness and (2) a transverse single shot turbo spin echo sequence (HASTE) with 4 mm slice thickness. For 3D-MRCP, TIRM, and HASTE, presence of PD and assessment of evaluability were determined in a randomized manner. A consensus read by two radiologists using 3D-MRCP, non-MRCP T2-weighted sequences, and other available imaging sequences served as reference standard for diagnosis of PD. Statistical analysis included performance analysis of 3D-MRCP, TIRM, and HASTE and testing for noninferiority of non-MRCP T2-weighted sequences compared with 3D-MRCP. Results Thirty-three of 342 patients (9.7%) were diagnosed with PD using the reference standard. Sensitivity/specificity of 3D-MRCP for detecting PD were 81.2%/69.7% (p < 0.001). Sensitivity/specificity of TIRM and HASTE were 92.5%/93.9 and 98.1%/97.0%, respectively (p < 0.001 each). Grouped sensitivity/specificity of non-MRCP T2-weighted sequences were 99.8%/91.0%. Non-MRCP T2-weighted sequences were non-inferior to 3D-MRCP alone for diagnosis of PD. 20.2, 7.3%, and 2.3% of 3D-MRCP, TIRM, and HASTE, respectively, were not evaluable due to motion artifacts or insufficient duct depiction. Conclusions Non-MRCP T2-weighted MRI sequences offer high performance for diagnosis of PD and are noninferior to 3D-MRCP alone. Trial registration Not applicable.
Abstract licence: CC BY-NC-ND
Reads
Read by people on this page
None yet.
Checked or read by AI through naulon
None yet.
A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.
Are you an author?
Is this your paper?
Claim it to add your note and be paid when agents cite it. Free.