Abstract
Background and aims Acute lower gastrointestinal bleeding (LGIB) is a common cause of emergency hospitalization and may require readmission for re-bleeding. Recently, a novel endoscopic hemostatic powder (UI-EWD/Nexpowder™, Nextbiomedical, Incheon, South Korea) was developed and applied for the control of LGIB. The aim of this study was to evaluate the hemostatic efficacy and long-term safety of UI-EWD in LGIB. Patients and methods We conducted a retrospective cohort study of LGIB at a single tertiary center in south Korea. One hundred and sixty-seven consecutive patients with LGIB who were initially successful in endoscopic hemostasis were included and divided into the conventional treatment group (n = 112) and the UI-EWD therapy group (n = 55; 38 patients with conventional treatment and 17 patients with UI-EWD alone). The success rate of hemostasis, adverse events related to UI-EWD, and re-bleeding rate were evaluated. Results The incidence of endoscopic hemostasis applied to the hepatic flexure (7.3% vs. 0%, p = 0.011) and larger than 4 cm (25.5% vs. 8.0%, p = 0.002) were significantly higher in the UI-EWD group than in the conventional therapy group. The cumulative rebleeding rate within 28 days in the UI-EWD group was 5.5% (3/55), which was significantly lower than that in the conventional treatment group (17.0% [19/112]; p = 0.039). No UI-EWD-related adverse events were recorded. Conclusion Based on our results, application of UI-EWD in LGIB showed promising results for the prevention of re-bleeding, especially in locations where it is difficult to approach or cases with more bleeding. There were no significant complications, such as perforation or embolism. In particular, UI-EWD should be considered first for anatomical or technical impediments to endoscopic access in LGIB.
Abstract licence: CC BY-NC-ND
Reads
Read by people on this page
None yet.
Checked or read by AI through naulon
None yet.
A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.
Are you an author?
Is this your paper?
Claim it to add your note and be paid when agents cite it. Free.