Not checkedNot checked for notices yet.
BioMonitor 2 in-office setting insertion safety and feasibility evaluation with device functionality assessment: results from the prospective cohort BioInsight study
Khaled Awad, Raul Weiss, Asim Yunus and 7 more
BMC Cardiovascular Disorders · 2020
doi:10.1186/s12872-020-01439-8 (opens in a new tab)
We email you when a new notice or a question about this paper appears.
Abstract
Abstract Background Insertable cardiac monitors are utilized for the diagnosis of arrhythmias and traditionally have been inserted within hospitals. Recent code updates allow for reimbursement of office-based insertions; however, there is limited information regarding the resources and processes required to support in-office insertions. We sought to determine the safety and feasibility of in-office insertion of the BioMonitor 2 and better understand in-office procedures, including patient selection, pre-insertion protocols, resource availability, and staff support. Methods Patients meeting an indication for a rhythm monitor were prospectively enrolled into this single-arm, non-randomized trial. All patients underwent insertion in an office setting. Two follow-up visits at days 7 and 90 were required. Information on adverse events, device performance, office site preparations, and resource utilization were collected. Results Eighty-two patients were enrolled at six sites. Insertion was successful in all 77 patients with an attempt. Oral anticoagulation was stopped in 20.8% of patients and continued through insertion in 23.4%, while prophylactic antibiotics were infrequently utilized (37.7% of study participants). On average, the procedure required a surgeon plus two support staff and 35 min in an office room to complete the 8.4 min insertion procedure. The mean R-wave amplitude was 0.77 mV at insertion and 0.67 mV at 90-days with low noise burden (2.7%). There were no procedure related complications. Two adverse events were reported (event rate 2.7% [95% CI 0.3, 9.5%]). Conclusions In-office insertion of the BioMonitor 2 is safe and feasible. Devices performed well with high R-wave amplitudes and low noise burden. These results further support shifting cardiac monitor insertions to office-based locations. Trial registration clinicaltrials.gov, NCT02756338. Registered 29 April 2016.
Abstract licence: CC BY-NC-ND
Reads
Read by people on this page
None yet.
Checked or read by AI through naulon
None yet.
A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.
Are you an author?
Is this your paper?
Claim it to add your note and be paid when agents cite it. Free.