The effects of ventilation on left-to-right shunt and regional cerebral oxygen saturation: a self-controlled trial

Peiyi Li, Jun Zeng, Wei Wei and 1 more

BMC Anesthesiology · 2019

doi:10.1186/s12871-019-0852-1 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

Abstract Background Increase of pulmonary vascular resistance (PVR) is an efficient method of modulating pulmonary and systemic blood flows (Qp/Qs) for patients with left-to-right (L-R) shunt, and is also closely associated with insufficient oxygen exchange for pulmonary hypoperfusion. So that it might be a preferred regime of maintaining arterial partial pressure of carbon dioxide tension (PaCO2) within an optimal boundary via ventilation management in congenital heart disease (CHD) patients for the inconvenient measure of the PVR and Qp/Qs. However, the appropriate range of PaCO2 and patient-specific mechanical ventilation settings remain controversial for CHD children with L-R shunt. Methods Thirty-one pediatric patients with L-R shunt, 1–6 yr of age, were included in this observation study. Patients were ventilated with tidal volume (VT) of 10, 8 and 6 ml/kg in sequence, and 15 min stabilization period for individual VT. The velocity time integral (VTI) of L-R shunt, pulmonary artery (PA) and descending aorta (DA) were measured with transesophageal echocardiography (TEE) after an initial 15 min stabilization period for each VT, with arterial blood gas analysis. Near-infrared spectroscopy sensor were positioned on the surface of the bilateral temporal artery to monitor the change in regional cerebral oxygen saturation (rScO2). Results PaCO2 was 31.51 ± 0.65 mmHg at VT 10 ml/kg vs. 37.15 ± 0.75 mmHg at VT 8 ml/kg (P < 0.03), with 44.24 ± 0.99 mmHg at VT 6 ml/kg significantly higher than 37.15 ± 0.75 mmHg at VT 8 ml/kg. However, PaO2 at a VT of 6 ml/kg was lower than that at a VT of 10 ml/kg (P = 0.05). Meanwhile, 72% (22/31) patients had PaCO2 in the range of 40-50 mmHg at VT 6 ml/kg. VTI of L-R shunt and PA at VT 6 ml/kg were lower than that at VT of 8 and 10 ml/kg (P < 0.05). rScO2 at a VT of 6 ml/kg was higher than that at a VT of 8 and 10 ml/kg (P < 0.05), with a significantly correlation between rScO2 and PaCO2 (r = 0.53). VTI of PA in patients with defect diameter > 10 mm was higher that that in patients with defect diameter ≤ 10 mm. Conclusions Maintaining PaCO2 in the boundary of 40-50 mmHg with VT 6 ml/kg might be a feasible ventilation regime to achieve better oxygenation for patients with L-R shunt. Continue raising PaCO2 should be careful. Trail registration Clinical Trial Registry of China (http://www.chictr.org.cn) identifier: ChiCTR-OOC-17011338, prospectively registered on May 9, 2017.

Abstract licence: CC BY-NC-ND

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.