Skip to content
naulon
Not checkedNot checked for notices yet.

Regional registration of whole slide image stacks containing major histological artifacts

Mahsa Paknezhad, Sheng Yang Michael Loh, Yukti Choudhury and 11 more

BMC Bioinformatics · 2020

doi:10.1186/s12859-020-03907-6 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

Background High resolution 2D whole slide imaging provides rich information about the tissue structure. This information can be a lot richer if these 2D images can be stacked into a 3D tissue volume. A 3D analysis, however, requires accurate reconstruction of the tissue volume from the 2D image stack. This task is not trivial due to the distortions such as tissue tearing, folding and missing at each slide. Performing registration for the whole tissue slices may be adversely affected by distorted tissue regions. Consequently, regional registration is found to be more effective. In this paper, we propose a new approach to an accurate and robust registration of regions of interest for whole slide images. We introduce the idea of multi-scale attention for registration. Results Using mean similarity index as the metric, the proposed algorithm (mean ± SD $$0.84 \pm 0.11$$ 0.84 ± 0.11 ) followed by a fine registration algorithm ( $$0.86 \pm 0.08$$ 0.86 ± 0.08 ) outperformed the state-of-the-art linear whole tissue registration algorithm ( $$0.74 \pm 0.19$$ 0.74 ± 0.19 ) and the regional version of this algorithm ( $$0.81 \pm 0.15$$ 0.81 ± 0.15 ). The proposed algorithm also outperforms the state-of-the-art nonlinear registration algorithm (original: $$0.82 \pm 0.12$$ 0.82 ± 0.12 , regional: $$0.77 \pm 0.22$$ 0.77 ± 0.22 ) for whole slide images and a recently proposed patch-based registration algorithm (patch size 256: $$0.79 \pm 0.16$$ 0.79 ± 0.16 , patch size 512: $$0.77 \pm 0.16$$ 0.77 ± 0.16 ) for medical images. Conclusion Using multi-scale attention mechanism leads to a more robust and accurate solution to the problem of regional registration of whole slide images corrupted in some parts by major histological artifacts in the imaged tissue.

Abstract licence: CC BY-NC-ND

References32

    32 more references, whose wording the paper’s licence keeps private.

    Reads

    Read by people on this page

    None yet.

    Checked or read by AI through naulon

    None yet.

    A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

    Are you an author?

    Is this your paper?

    Claim it to add your note and be paid when agents cite it. Free.