Skip to content
naulon
Not checkedNot checked for notices yet.

A comparison of airway management devices in simulated entrapment-trauma: a prospective manikin study

Robin Pap, Charl van Loggerenberg

International Journal of Emergency Medicine · 2019

doi:10.1186/s12245-019-0233-z (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

Abstract Introduction In the patient entrapped after a motor vehicle collision (MVC), advanced airway management may need to be performed before extrication. The aim of this study was to compare four airway management devices utilized by paramedics in a simulated entrapped patient. Methods Twenty-six paramedics performed advanced airway management on a manikin seated in the driver’s seat (right side) of a car. Access was through the opened door only. The airway devices were the Macintosh laryngoscope and the Airtraq optical laryngoscope to facilitate the endotracheal intubation (ETI), the laryngeal mask airway (LMA) Supreme and the laryngeal tube (LT). Time to first successful ventilation and number of attempts required for successful placement were measured. Following each placement, participants rated the degree of difficulty. For ETI, participants ranked the achieved glottic view using Cormack-Lehane grades (CLG). Finally, participants were asked which airway management device they preferred. Results The LMA Supreme had the shortest mean time to first successful ventilation (16.7 s, CI [0.95] 14.9–18.6). Insertion of the LMA Supreme and ETI with the Macintosh laryngoscope had 100% first-attempt success. The LMA Supreme was rated least difficult to insert (mean score 1.7/10 (CI [0.95] 1.2–2.1)). Compared to the Macintosh, the Airtraq laryngoscope facilitated superior laryngoscopy (CLG I view 46.2% and 80.8%, respectively). Most participants (10/26; 38%) chose the Macintosh laryngoscope as their preferred technique, followed closely by the LMA Supreme (9/26; 35%). Conclusion The LMA Supreme took the least amount of time and was the easiest to be inserted. Extraglottic airway devices may be beneficial alternative airway management devices to be considered by paramedics in the entrapped patient. Endotracheal intubation using the Macintosh laryngoscope was performed competently by participating paramedics. The Airtraq enabled superior laryngoscopy but resulted in poorer first-pass success rate.

Abstract licence: CC BY-NC-ND

References36

    36 more references, whose wording the paper’s licence keeps private.

    Reads

    Read by people on this page

    None yet.

    Checked or read by AI through naulon

    None yet.

    A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

    Are you an author?

    Is this your paper?

    Claim it to add your note and be paid when agents cite it. Free.