Skip to content
naulon

Not checkedNot checked for notices yet.

A new ligament-compatible patient-specific 3D-printed implant and instrumentation for total ankle arthroplasty: from biomechanical studies to clinical cases

C. Faldini, A. Mazzotti, C. Belvedere and 4 more

Journal of Orthopaedics and Traumatology · 2020

doi:10.1186/s10195-020-00555-7 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

Abstract Background Computer navigation and patient-specific instrumentation for total ankle arthroplasty have still to demonstrate their theoretical ability to improve implant positioning and functional outcomes. The purpose of this paper is to present a new and complete total ankle arthroplasty customization process for severe posttraumatic ankle joint arthritis, consisting of patient-specific 3D-printed implant and instrumentation, starting from a ligament-compatible design. Case presentation The new customization process was proposed in a 57-year-old male patient and involved image analysis, joint modeling, prosthesis design, patient-specific implant and instrumentation development, relevant prototyping, manufacturing, and implantation. Images obtained from a CT scan were processed for a 3D model of the ankle, and the BOX ankle prosthesis (MatOrtho, UK) geometries were customized to best fit the model. Virtual in silico, i.e., at the computer, implantation was performed to optimize positioning of these components. Corresponding patient-specific cutting guides for bone preparation were designed. The obtained models were printed in ABS by additive manufacturing for a final check. Once the planning procedure was approved, the models were sent to final state-of-the-art additive manufacturing (the metal components using cobalt-chromium-molybdenum powders, and the guides using polyamide). The custom-made prosthesis was then implanted using the cutting guides. The design, manufacturing, and implantation procedures were completed successfully and consistently, and final dimensions and location for the implant corresponded with the preoperative plan. Immediate post-op X-rays showed good implant positioning and alignment. After 4 months, clinical scores and functional abilities were excellent. Gait analysis showed satisfactory joint moment at the ankle complex and muscle activation timing within normality. Conclusions The complete customization process for total ankle arthroplasty provided accurate and reliable implant positioning, with satisfactory short-term clinical outcomes. However, further studies are needed to confirm the potential benefits of this complete customization process. Level of evidence 5. Case report.

Abstract licence: CC BY-NC-ND

References29

    29 more references, whose wording the paper’s licence keeps private.

    Reads

    Read by people on this page

    None yet.

    Checked or read by AI through naulon

    None yet.

    A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

    Are you an author?

    Is this your paper?

    Claim it to add your note and be paid when agents cite it. Free.