Comparative analysis of four methods to extract DNA from paraffin-embedded tissues: effect on downstream molecular applications
Savelkoul Paul HM, van der Linden Johannes C, Damen Jan and 2 more
BMC Research Notes · 2010
doi:10.1186/1756-0500-3-239 (opens in a new tab)
We email you when a new notice or a question about this paper appears.
Abstract
<p>Abstract</p> <p>Background</p> <p>A large portion of tissues stored worldwide for diagnostic purposes is formalin-fixed and paraffin-embedded (FFPE). These FFPE-archived tissues are an extremely valuable source for retrospective (genetic) studies. These include mutation screening in cancer-critical genes as well as pathogen detection. In this study we evaluated the impact of several widely used DNA extraction methods on the quality of molecular diagnostics on FFPE tissues.</p> <p>Findings</p> <p>We compared 4 DNA extraction methods from 4 identically processed FFPE mammary-, prostate-, colon- and lung tissues with regard to PCR inhibition, real time SNP detection and amplifiable fragment size. The extraction methods, with and without proteinase K pre-treatment, tested were: 1) heat-treatment, 2) QIAamp DNA-blood-mini-kit, 3) EasyMAG NucliSens and 4) Gentra Capture-Column-kit.</p> <p>Amplifiable DNA fragment size was assessed by multiplexed 200-400-600 bp PCR and appeared highly influenced by the extraction method used. Proteinase K pre-treatment was a prerequisite for proper purification of DNA from FFPE. Extractions with QIAamp, EasyMAG and heat-treatment were found suitable for amplification of fragments up to 400 bp from all tissues, 600 bp amplification was marginally successful (best was QIAamp). QIAamp and EasyMAG extracts were found suitable for downstream real time SNP detection. Gentra extraction was unsuitable. Hands-on time was lowest for heat-treatment, followed by EasyMAG.</p> <p>Conclusions</p> <p>We conclude that the extraction method plays an important role with regard to performance in downstream molecular applications.</p>
Abstract licence: CC BY-NC-ND
References46
- 15.
- 23.
38 more references, whose wording the paper’s licence keeps private.
All 46 referencesCited by papers we hold1
Reads
Read by people on this page
None yet.
Checked or read by AI through naulon
None yet.
A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.
Are you an author?
Is this your paper?
Claim it to add your note and be paid when agents cite it. Free.