No retraction, correction or concern found when last checked on Oct 26, 2026.
Noninvasive Fetal Trisomy (NIFTY) test: an advanced noninvasive prenatal diagnosis methodology for fetal autosomal and sex chromosomal aneuploidies
Fuman Jiang, Jinghui Ren, Fang Chen and 33 more
BMC Medical Genomics · 2012
Abstract
Background. Conventional prenatal screening tests, such as maternal serum tests and ultrasound scan, have limited resolution and accuracy.
Methods. We developed an advanced noninvasive prenatal diagnosis method based on massively parallel sequencing. The Noninvasive Fetal Trisomy (NIFTY) test, combines an optimized Student’s t-test with a locally weighted polynomial regression and binary hypotheses. We applied the NIFTY test to 903 pregnancies and compared the diagnostic results with those of full karyotyping.
Results. 16 of 16 trisomy 21, 12 of 12 trisomy 18, two of two trisomy 13, three of four 45, X, one of one XYY and two of two XXY abnormalities were correctly identified. But one false positive case of trisomy 18 and one false negative case of 45, X were observed. The test performed with 100% sensitivity and 99.9% specificity for autosomal aneuploidies and 85.7% sensitivity and 99.9% specificity for sex chromosomal aneuploidies. Compared with three previously reported z-score approaches with/without GC-bias removal and with internal control, the NIFTY test was more accurate and robust for the detection of both autosomal and sex chromosomal aneuploidies in fetuses.
Conclusion. Our study demonstrates a powerful and reliable methodology for noninvasive prenatal diagnosis.
Full text
From PubMed Central, U.S. National Library of Medicine, as current on Oct 26, 2026. Paragraph numbers are ours, so an answer can point at one.
Background
Down syndrome (Trisomy 21), Edward syndrome (Trisomy 18) and Patau syndrome (Trisomy 13) are the most clinically significant autosomal aneuploidies, and the incidence of autosomal abnormalities can be as high as one in 160 live births. Turner’s syndrome (45, X), Klinefelter’s syndrome (47, XXY) and XYY syndrome are common sex chromosomal aneuploidies that are associated with reproductive loss, infertility and language development delays, among others. Sex chromosomal aneuploidies occur in one out of 500 male births and one out of 850 female births.
Conventional prenatal diagnostic methods for detecting aneuploidies, such as karyotyping, FISH and QF-PCR, which rely on invasive procedures, bear potential risks for miscarriage. Noninvasive screening for fetal aneuploidies using maternal serum markers and ultrasound scans entails less risk, but offers limited sensitivity and specificity.
When Lo et al. first reported cell-free fetal DNA (cff-DNA) in 1997, and they highlighted its potential clinical utility as a biomarker because it can be detected from as early as four gestational weeks. Cell-free fetal DNA clears rapidly from the maternal circulation after delivery. However, the fraction of fetal DNA in the maternal plasma varies from 5% to 10%, which makes it difficult to detect genetic variation in the fetus. Conventional molecular techniques, such as allele-specific polymerase chain reaction (PCR) or quantitative real-time PCR, which aim to detect fetal chromosomal disorders, focus only on specific populations, such as fetuses with heterozygous alleles. The recent rapid development of massively parallel sequencing (MPS) technology now makes it possible to noninvasively detect fetal aneuploidies in a clinical setting. Several recent studies demonstrated that fetal aneuploidies could be detected and quantified via high-throughput whole-genome sequencing of maternal plasma cell-free DNA combined with a standard z-score test. Prior studies by Chiu et al. and Ehrich et al. suggest that an MPS-based approach is reliable at detecting trisomy 21.
In principle, an MPS-based approach that resolves whole genome information should be applicable for detecting aneuploidies in all of the chromosomes. Chen et al. showed, however, that such test was less successful for detecting trisomy 18 and trisomy 13 compared with trisomy 21. The mixed results may be related to the GC-bias caused by the sample preparation or sequencing procedures. Quake et al. developed a method to remove the effect of GC-bias, and thus significantly improve the sensitivity of the MPS-based approach for detecting trisomy 18 and trisomy 13. Another recent study reported the possibility of detecting sex chromosomal aneuploidies using an internal chromosome control approach.
In this study, we developed an advanced GC-correlation methodology for an MPS-based, noninvasive fetal trisomy (NIFTY) test. Our technique has higher sensitivity and specificity than all previously reported z-score approaches for the detection of autosomal and sex chromosomal aneuploidy.
Study participants and data production
We enrolled 903 pregnant women with ages ranging from 20 to 45 years. The gestational ages varied from 10 to 34 weeks, covering the first to the third trimesters. Based on the results of full karyotyping using amniotic fluid, 866 of the fetuses were euploid and 37 were aneuploid. The cases of aneuploidy included two cases of trisomy 13, 12 cases of trisomy 18, 16 cases of trisomy 21, four cases of 45,X (three typical cases of 45,X and one mosaic case of 45, X ([27]/46, XX [23]), two cases of XXY and one case of XYY. We obtained 2–4 million reads for each sample. After alignment and filtering, the average data volume for aneuploidy detection was 1.7 million uniquely aligned reads. We constructed a comprehensive bioinformatics pipeline to scan for fetal chromosomal aneuploidies. The pipeline comprised short reads alignment, GC content correction, fetal DNA concentration estimation, t-test of a binary hypothesis, and fetal gender classification (Figure 1).
The relationship between GC content and sequencing bias
To investigate the relationship between GC content and sequence bias, we selected 300 control pregnancies with normal karyotypes and plotted the relative reads coverage for each chromosome against the corresponding GC content (Additional file 1: Figure S1). The relative reads coverage of the different chromosomes was strongly related to the inherent chromosomal GC content, and the correlation between the two factors varied among the chromosomes. We observed a significant positive correlation between the reads coverage and GC content for chromosomes with an average GC content greater than 41%, whereas we observed, a significant negative correlation between the reads coverage and GC content for chromosomes with an average GC content less than 41%. Among the chromosomes with average GC content close to 41% the reads coverage was not correlated with GC content (Additional file 2: Figure S2). To further investigate the effect of GC content on reads coverage, we examined the hidden relationship between chromosome structure and inherent GC content. We classified all of the unique 35-mers in the genome into 36 levels based on the numbers of guanine (G) and cytosine (C) bases, ranging from 0 to 35. We used the 35-mer counts to cluster the chromosomes according to their GC levels within a matrix (Additional file 3: Figure S3). Chromosomes 19 and 22 clustered together because of their higher inherent GC contents, while chromosome 4 and 13 clustered together for their lower inherent GC contents. The differences in the inherent GC content of the chromosomes combined with the sequencer-related GC-bias explained the significant correlation between reads coverage and corresponding GC content. For example, chromosome 13 has a relatively low GC content, the PCR and sequencing process enriched chromosomes with higher GC content, leading to relatively low reads coverage for chromosome 13 and thus a negative correlation between the reads coverage and GC content among the chromosomes (Additional file 1: Figure S1).
The relationship between cell-free fetal DNA concentration and gestational week
Previous work demonstrated that the cff-DNA concentration was the lynchpin in fetus aneuploidy detection. To assess the best strategy for clinical applications, we examined the relationship between cell-free fetal DNA concentration and the gestational week. We examined the 443 plasma samples with male fetal to appraise the approximate probability relationship. Using Losses regression, we found that the amount of cff-DNA increased significantly with the gestational week (Additional file 4: Figure S4). The correlation coefficient of the linear regression was only 0.1246, however, indicating that there might be a more complex mechanism driving the cff-DNA concentrations.
Quantitative description of data volatility and tags number
The volatility of the relative reads coverage was one of the major factors affecting the sensitivity and specificity of aneuploidy detection. To quantify the volatility of the relative reads coverage, we used the standard deviation of the difference between the observed and fitted relative reads coverage. We found that for each chromosome the standard deviation was stable when the numbers of samples was larger than 100 (Additional file 5: Figure S5). We also found that the depth of sequencing strongly influenced the accuracy of aneuploidy detection. We isolated 150 plasma samples with euploid fetuses to inspect the relationship between the tags number (unique reads) and the standard deviation of relative reads coverage. On each chromosome, the standard deviation of relative reads coverage among the 150 samples was significantly correlated with the numbers of tags (Additional file 6: Figure S6). We further estimated the effects of the gestational week and the number of tags on the power of our statistical method to detect fetal aneuploidy in chromosomes 13, 18, 21 and X (Additional file 7: Figure S7). In most cases, the detection power increased with both gestational week and the number of sequencing reads. We also found that the detection power was higher when the fetus was male; it may be due to the more accurate estimation of cff-DNA concentration.
Robust data quality control of the GC-correlation t-test
Several indicators were used to judge the quality of the sequence data. We classified these indicators into two categories: direct and indirect. The indirect indicators of the accuracy of NIFTY test came from the sequencing procedure: Q20% refers to the fraction of bases within the sequenced reads with an Illumina quality score greater than 20, and the PCR duplication rate, refers to the fraction of the reads sharing the same start position and end positions on the reference genome. The direct indicators came from the data analysis procedure and included the number of unique reads (Figure 2), the genome-wide average GC content, and the consistency between the test samples and the reference controls.
Aneuploidy detection with NIFTY test
The NIFTY test performed with 100% sensitivity and specificity for the detection of trisomy 13 (two out of two) (Figure 3a) and trisomy 21 (16 out of 16) (Figure 3c). For trisomy 18, the NIFTY test detected 12 of 12 cases and identified 890 of 891 healthy controls (Figure 3b), indicating 100% sensitivity and 99.7% specificity, corresponding to zero false negative results and a false positive rate of 0.3%. The false positive occurred in a sample from gestational week 21. Our GC-correlation t-test approach correctly detected sex chromosomal abnormalities. For Turner’s syndrome, the NIFTY test identified three out of four XO cases but failed to detect the mosic 45, X case which was in gestational week of 25 and had a normal karyotype in 46% of the cells sampled. Thus, the sensitivity and specificity of our approach for the detection of Turner’s syndrome were 75% and 99.9%, respectively; in other words, the false negative rate was 25% and false positive rate was 0.1% for 45, X detection using the NIFTY test. The test performed with 100% sensitivity and specificity for the detection of XXY (two out of two) or XYY (one out of one) (Figure 3e and f).
The NIFTY test correctly identified the sex of approximately 99.9% of the 896 fetuses, 443 male and 452 female, which did not have sex chromosomal aneuploidies. The NIFTY test was inconclusive for one fetus that was determined to be 46, XX by karyotyping.
Comparison between different aneuploidy detection approaches
To evaluate the performance of the NIFTY test in the detection of fetal aneuploidy, we compared it with the performance of three other previously reported approaches to analyse our 903 cases, with full karyotyping of the same 300 euploid cases. Chiu et al. used the standard z-score approach without any GC-bias removal to detect Down syndrome. Chen et al. developed a z-score approach with a different GC-bias removal strategy, which we named the “GC-correct z-score approach.” Lau et al. previously demonstrated a internal chromosome control based z-score approach.
We used the coefficient of variation (CV) to evaluate the performances of these four approaches (Figure 4). Additionally, we found that the CV for the standard z-score approach was larger than that for other approaches among clinically relevant chromosomes (13, 18 and 21). Thus, the standard z-score approach has a low sensitivity for the detection of trisomies 13 and 18 (Table 1). The performance of the GC-correct z-score approaches and our NIFTY test were close, both demonstrated over 99% sensitivity and specificity for the detection of trisomy 13, 18 and 21 (Table 1). It was difficult to precisely detect sex chromosomal aneuploidy using the GC-correct z-score approach due to fetal gender confusion. The internal chromosome control approach displayed larger CV values for chromosomies 13, 18, and 21 and had a higher risk of false negatives related to XXY and XYY detection. In contrast, the NIFTY test had increased accuracy in the detection of sex chromosomal aneuploidies, such as XO, XXY and XYY (Table 1).
Discussion
The cost of high throughput sequencing decreased dramatically over the past few years, thus increasing its utility for clinical practices. In this study, we demonstrated the NIFTY test is a novel MPS-based method for noninvasively detecting fetal aneuploidies. the NIFTY test proved to be a reliable and timely method for detecting both autosomal and sex chromosomal aneuploidies, especially trisomy 21, trisomy 18, trisomy 13, XO, XXY and XYY.
GC-bias is a common issue for applications using the current massively parallel sequencing platforms, and it can be introduced either by sample preparation or the sequencing procedure. In this study, we observed that sequencers appear to have a preferred GC ranges, and the differences in GC composition among different chromosomes can act as an intrinsic factor influencing the degree of data fluctuation. We employed GC-correlation to significantly reduce the effect of GC-bias. Using the same reagents for library construction and sequencing, and improving the image analysis software may be useful in further minimizing the GC-bias.
The small fetal DNA fraction in the maternal blood was the main limitation on sequencing dependent noninvasive prenatal diagnosis. The required number of unique reads increases exponentially when the concentration of cff-DNA falls to less than 3.5%, which is consistent with the results of a previous study. An advantage of our approach is that the quality-control procedure uses the estimation of cff-DNA concentration as a key index. Thus, the quality-control procedure, improves the accuracy of fetal aneuploidy detection. Another improvement of our methodology over previous methods is the change from sole reliance on a binary hypothesis to a more comprehensive statistical model. Our statistical model strengthens the theoretical sensitivity of the test; the NIFTY test performed with 100% sensitivity and 99.9% specificity for detecting autosomal aneuploidies and 85.7% sensitivity and 99.9% specificity for detecting sex chromosomal aneuploidies.
Using the NIFTY test we treated each chromosome as a whole, which allowed us to focus on detecting the aneuploidies. In principle, we could detect other chromosomal abnormalities resulting in serious clinical consequences, such as microdeletions and microduplications, by slicing the chromosomes into smaller fragments and increasing the number of sequencing tags. It is also possible to detect mutations, such as those underlying Mendelian diseases, in genes or regions of interest through target region capture and high depth sequencing.
Although we achieved high detection accuracy in a cohort of 903, the sample size in this study was a limiting factor because the incidence of aneuploidies in the general population is low. To precisely estimate sensitivity and specificity of our procedure, large-scale, multi-center clinical trials will be required in the future. Additionally, the conventional approaches for cff-DNA concentration estimation are mostly locus-specific and only applicable to limited population. Our approach was also less accurate in assessing the cff- DNA concentration for female fetuses. Further studies should focus on developing an unbiased method to precisely estimate the fraction of cff-DNA in the maternal plasma.
Conclusions
In this study we demonstrate a robust and accurate methodology to detect fetal aneuploidies using MPS. This is the first study to systematically identify sex chromosomal aneuploidies with maternal plasma DNA sequencing. We hope the use of this method in clinical practices will contribute to reducing the number of birth defects.
Sample recruitment
From June 2009 to August 2010, we recruited a total of 903 participants prospectively from the Shenzhen People’s Hospital, the Zhuhai Municipal Maternal and Child Healthcare Hospital and the Shenzhen Maternal and Child Care Center. We recruited another 19 euploid adult males for the estimation of fetal DNA fraction. Institutional Review Board approval was obtained at each site, and all participants gave informed written consent. We obtained the full karyotyping results for all samples from regular clinical tests. We randomly selected 300 euploid samples among the karyotyping results to use as the reference controls.
Maternal plasma DNA sequencing
We collected five ml peripheral venous blood from 903 pregnant women in EDTA tubes. The tubes were centrifuged at 1,600 × g for 10 min within four hours of collection. Plasma was transferred to microcentrifuge tubes and centrifuged at 16,000 × g for 10 min to remove residual cells. Cell-free plasma was stored at −80°C until DNA extraction. Each plasma sample was frozen and thawed only once.
For massively parallel genomic sequencing, DNA fragments from 600 ul of maternal plasma were used for library construction according to a modified protocol from Illumina. End-repairing of maternal plasma DNA fragments was performed using T4 DNA polymerase, Klenow polymerase, and T4 polynucleotide kinase. Afterwards, A-base tailing adapters were ligated to the DNA fragments. Standard multiplex primers were introduced by 17-cycle PCR. The libraries were analysed for size distribution by Agilent Bioanalyzer and quantified using real-time PCR. Thirty-six-cycle single-end multiplex sequencing and 50-cycle single-end multiplex sequencing were used for the Illumina GAIIx and Illumina HiSeq 2000 platform, respectively.
High effective alignment with universal unique reads set
Computationally, we incised the human reference genome (HG 18, NCBI build 36) into k-mers (k refers to the length of the sequencing reads) and then aligned the k-mers back to the reference genome. All of the k-mers that could be uniquely mapped to a single position on the reference genome, the unique mapping reads, were named as the universal unique reads set. We selected the sequencing reads that could be mapped with 0-mismatch to the universal unique reads set (i.e. the tag) for our analysis.
K-mer coverage and GC-correlation
We computed the k-mer coverage for each chromosome and every sample, as where is the ID of control samples; j is the chromosome ID; ni,j is the number of unique reads mapped onto chromosome j from sample i and Ni,j was the total number of unique reads for chromosome j. Because of the differences among the samples, we normalized the data and computed the relative k-mer coverage for each sample as, where was the average k-mer coverage of the 22 autosomes in the i-th sample.
Given the unclear mechanism of GC-bias, we performed a Losses regression to fit the relative k-mer coverage to the corresponding GC content. We denoted the fitted relative k-mer coverage as cr′i,j = fj(GCi,j). The fitted value, which we used as the theoretical value, was vital to our statistical model for cff-DNA concentration estimation and aneuploidy detection.
Because we using a male/female data set, we had different fitted values for the analysis of sex chromosomes. We calculated the fitted relative k-mer values for the sex chromosome analysis as follows:
cr′i,j,m = fj,m(GCi,j) · (j = X, Y), for the fitted relative k-mer coverage from a regression of an adult male data set; and
cr′i,j,f = fj,f(GCi,j) · (j = X, Y), for the fitted relative k-mer coverage from a regression of a fetal-female data set.
Cff-DNA concentration estimation
Using the gender difference to compute the relative k-mer coverage of the sex chromosome, we estimated the cff-DNA concentrations, which denote as ε. Subscripts corresponding to chromosome IDs indicate concentrations estimated from different chromosomes:
, is the estimation using the data for chromosome Y; and
, is the estimation using data for chromosome X.
Autosomal aneuploidy detection with binary hypothesis
We developed a binary hypothesis strategy to achieve a higher sensitivity and specificity. We performed two Student’s t-test based on null/alternative hypotheses, and we subsequently calculated the relative logarithmic likelihood odds ratio. The null and alterative hypothesizes are shown below.
For the first test:
H0 (null hypothesis): the fetal chromosome was euploid.
H1 (alterative hypothesis): the fetal chromosome was trisomic.
The first t-value,.
For the second test:
H0 (null hypothesis): the test fetal chromosome was trisomic.
H1 (alterative hypothesis): the test fetal chromosome was euploid.
The second t-value,.
The logarithmic likelihood odds ratio between our binary hypotheses was defined as
where DOF = the degree of freedom., We used, │ti,j,firsti,j,first│> 3 and │ti,j,secondi,j,second│< 3 as warning criteria. From the logarithmic likelihood odds ratio, we could make a confident judgment of autosomal aneuploidy if Li,j > 1.
Fetal gender classification and sex chromosomal aneuploidy detection
We developed a double standard strategy with an experimental threshold and logistic regression to detect the fetal gender. The k-mer coverage on chromosome Y was an ideal choice for distinguishing genders. Based on the 300 reference controls, we considered cri,Y < 0.04 the threshold for identifying a female fetus, while we regarded samples with cri,Y > 0.051 as having a male fetus. We considered samples with 0.04 <cri,Y < 0.051 to be gender-uncertain.
Additionally, we developed a logistic regression strategy to improve the specificity of the gender determination. We computed the probability (Pi) of that a fetus was male by the following formula:
, where the parameters (β0, β1, β2) were determined by regression using the 300 reference controls mentioned above.
We regarded samples with pi > 0.8 as having male fetuses, samples with pi < 0.3 as having female fetuses, and the remaining samples as being gender-uncertain.
After gender classification, we performed XXX and XO detection on samples with a female fetus and XXY and XYY detection on samples with a male fetus.
For samples with a female fetus, we performed a t-test for chromosome abnormality detection.
where sdX,f is the standard deviation of cri,X,f − cr′i,X,f calculated from the reference controls with female fetuses; we expected sdX,f to equal zero. We considered samples with ti,X or ti,X < -2.5 to be XXX or XO.
For a male fetus, we first supposed that chromosome Y is monosomic and extrapolated the fitted k-mer coverage for chromosome X, with the fetal DNA fraction estimated only by the k-mer coverage of chromosome Y. We calculated the t-score by the following formula:
, where εi,Y is the estimated cff-DNA concentration using chromosome Y data, and is the standard deviation of cri,X,f − cr′i,X,f calculated from the reference controls carrying female fetuses with an expectation of zero. Both of these quantities are defined above.
We regarded samples with ti >2.5 as being XXY or XYY. Additionally, the cff-DNA concentration estimated by chromosome X and Y independently is a combined marker for sex chromosomal aneuploidy detection especially XXY and XYY. For an XXY sample, not only was the ti >2.5 but also the cff-DNA concentration estimated by chromosome X was nearly zero, with a confidence interval from −0.03 to 0.03; For an XYY samples, not only the ti >2.5, but the R-value (Ratio of the cff-DNA concentration estimated by chromosome Y to that estimated by chromosome X) was nearly two, reflecting the fact that there were two copies of chromosome Y and only a single copy of chromosome X.
Competing interest
The authors declare that they have no competing interests.
Authors’ contributions
ZXQ, RJH, WJI and WJU conceived and designed the study; WW, ZYQ, SD, SY, ZHK, XJS, SW, YBM, ZLJ, XJH, ZZY, and LLH recruited participants and separated the plasma samples; CF, LYH, PXY, XZL, ZHY, TZM, LPP, LQY, GH, and JH performed library construction and sequencing; JFM, ZWM, CXH, LYR and LSG developed the methodology and LLF, CHF, ZCL and YYY participated in the alignment of the sequencing data and data analysis; JFM and CSP wrote the manuscript. All authors read and approved the final manuscript.
Pre-publication history
The pre-publication history for this paper can be accessed here:
http://www.biomedcentral.com/1755-8794/5/57/prepub
References 35
- 1.
Driscoll DA Gross S Clinical practice. Prenatal screening for aneuploidyN Engl J Med2009 3602425562562
Not in our library10.1056/nejmcp0900134
- 2.
Bouchlariotou S Tsikouras P Dimitraki M Athanasiadis A Papoulidis I Maroulis G Liberis A Liberis V Turner’s syndrome and pregnancy: has the 45, X/47, XXX mosaicism a different prognosis? Own clinical experience and literature reviewJ Matern Fetal Neonatal Med2011 245668672
Not in our library10.3109/14767058.2010.520769
- 3.
- 4.
Hofherr SE Wiktor AE Kipp BR Dawson DB Van Dyke DL Clinical diagnostic testing for the cytogenetic and molecular causes of male infertility: the Mayo Clinic experienceJ Assist Reprod Genet2011 281110911098
Not in our library10.1007/s10815-011-9633-6
- 5.
Rives N Simeon N Milazzo JP Barthelemy C Mace B Meiotic segregation of sex chromosomes in mosaic and non-mosaic XYY males: case reports and review of the literatureInt J Androl2003 264242249
Not in our library10.1046/j.1365-2605.2003.00421.x
- 6.
Park JH Burns-Cusato M Dominguez-Salazar E Riggan A Shetty S Arnold AP Rissman EF Effects of sex chromosome aneuploidy on male sexual behaviorGenes Brain Behav2008 76609617
Not in our library10.1111/j.1601-183x.2008.00397.x
- 7.
- 8.
Sybert VP McCauley E Turner’s syndromeN Engl J Med2004 3511212271238
Not in our library10.1056/nejmra030360
- 9.
Mujezinovic F Alfirevic Z Procedure-related complications of amniocentesis and chorionic villous sampling: a systematic reviewObstet Gynecol2007 1103687694
Not in our library10.1097/01.aog.0000278820.54029.e3
- 10.
Pitukkijronnakorn S Promsonthi P Panburana P Udomsubpayakul U Chittacharoen A Fetal loss associated with second trimester amniocentesisArch Gynecol Obstet2011 2844793797
Not in our library10.1007/s00404-010-1727-3
- 11.
Kagan KO Wright D Valencia C Maiz N Nicolaides KH Screening for trisomies 21, 18 and 13 by maternal age, fetal nuchal translucency, fetal heart rate, free beta-hCG and pregnancy-associated plasma protein-AHum Reprod2008 23919681975
Not in our library10.1093/humrep/den224
- 12.
Canick J Prenatal screening for trisomy 21: recent advances and guidelinesClin Chem Lab Med2011 50610031008
Not in our library10.1515/cclm.2011.671
- 13.
Lo YM Corbetta N Chamberlain PF Rai V Sargent IL Redman CW Wainscoat JS Presence of fetal DNA in maternal plasma and serumLancet1997 3509076485487
Not in our library10.1016/s0140-6736(97)02174-0
- 14.
Simpson JL Choosing the best prenatal screening protocolN Engl J Med2005 3531920682070
Not in our library10.1056/nejme058189
- 15.
Bischoff FZ Sinacori MK Dang DD Marquez-Do D Horne C Lewis DE Simpson JL Cell-free fetal DNA and intact fetal cells in maternal blood circulation: implications for first and second trimester non-invasive prenatal diagnosisHum Reprod Update2002 86493500
Not in our library10.1093/humupd/8.6.493
- 16.
Illanes S Denbow M Kailasam C Finning K Soothill PW Early detection of cell-free fetal DNA in maternal plasmaEarly Hum Dev2007 839563566
Not in our library10.1016/j.earlhumdev.2006.11.001
- 17.
Lo YM Zhang J Leung TN Lau TK Chang AM Hjelm NM Rapid clearance of fetal DNA from maternal plasmaAm J Hum Genet1999 641218224
Not in our library10.1086/302205
- 18.
Birch L English CA O’Donoghue K Barigye O Fisk NM Keer JT Accurate and robust quantification of circulating fetal and total DNA in maternal plasma from 5 to 41 weeks of gestationClin Chem2005 512312320
Not in our library10.1373/clinchem.2004.042713
- 19.
Lo YM Tein MS Lau TK Haines CJ Leung TN Poon PM Wainscoat JS Johnson PJ Chang AM Hjelm NM Quantitative analysis of fetal DNA in maternal plasma and serum: implications for noninvasive prenatal diagnosisAm J Hum Genet1998 624768775
Not in our library10.1086/301800
- 20.
Lo YM Tsui NB Chiu RW Lau TK Leung TN Heung MM Gerovassili A Jin Y Nicolaides KH Cantor CR Plasma placental RNA allelic ratio permits noninvasive prenatal chromosomal aneuploidy detectionNat Med2007 132218223
Not in our library10.1038/nm1530
- 21.
Tsui NB Chiu RW Ding C El-Sheikhah A Leung TN Lau TK Nicolaides KH Lo YM Detection of trisomy 21 by quantitative mass spectrometric analysis of single-nucleotide polymorphismsClin Chem2005 511223582362
Not in our library10.1373/clinchem.2005.056978
- 22.
Tong YK Ding C Chiu RW Gerovassili A Chim SS Leung TY Leung TN Lau TK Nicolaides KH Lo YM Noninvasive prenatal detection of fetal trisomy 18 by epigenetic allelic ratio analysis in maternal plasma: theoretical and empirical considerationsClin Chem2006 521221942202
Not in our library10.1373/clinchem.2006.076851
- 23.
Chiu RW Chan KC Gao Y Lau VY Zheng W Leung TY Foo CH Xie B Tsui NB Lun FM Noninvasive prenatal diagnosis of fetal chromosomal aneuploidy by massively parallel genomic sequencing of DNA in maternal plasmaProc Natl Acad Sci USA2008 105512045820463
Not in our library10.1073/pnas.0810641105
- 24.
Fan HC Blumenfeld YJ Chitkara U Hudgins L Quake SR Noninvasive diagnosis of fetal aneuploidy by shotgun sequencing DNA from maternal bloodProc Natl Acad Sci USA2008 105421626616271
Not in our library10.1073/pnas.0808319105
- 25.
Ehrich M Deciu C Zwiefelhofer T Tynan JA Cagasan L Tim R Lu V McCullough R McCarthy E Nygren AO Noninvasive detection of fetal trisomy 21 by sequencing of DNA in maternal blood: a study in a clinical settingAm J Obstet Gynecol2011 2043e201e211205
Not in our library10.1016/j.ajog.2010.12.060
- 26.
Chiu RW Akolekar R Zheng YW Leung TY Sun H Chan KC Lun FM Go AT Lau ET To WW Non-invasive prenatal assessment of trisomy 21 by multiplexed maternal plasma DNA sequencing: large scale validity studyBMJ2011 342c7401
Not in our library10.1136/bmj.c7401
- 27.
- 28.
- 29.
Lau TK Chen F Pan X Pooh RK Jiang F Li Y Jiang H Li X Chen S Zhang X Noninvasive prenatal diagnosis of common fetal chromosomal aneuploidies by maternal plasma DNA sequencing.J Matern Fetal Neonatal Med2011 25813701374
Not in our library10.3109/14767058.2011.635730
- 30.
- 31.
Bell CJ Dinwiddie DL Miller NA Hateley SL Ganusova EE Mudge J Langley RJ Zhang L Lee CC Schilkey FD Carrier testing for severe childhood recessive diseases by next-generation sequencingSci Transl Med2011 36565ra64
Not in our library10.1126/scitranslmed.3001756
- 32.
Cheung MS Down TA Latorre I Ahringer J Systematic bias in high-throughput sequencing data and its correction by BEADSNucleic Acids Res2011 3915e103
Not in our library10.1093/nar/gkr425
- 33.
- 34.
Liao GJ Lun FM Zheng YW Chan KC Leung TY Lau TK Chiu RW Lo YM Targeted massively parallel sequencing of maternal plasma DNA permits efficient and unbiased detection of fetal allelesClin Chem2011 57192101
Not in our library10.1373/clinchem.2010.154336
- 35.
Purwosunu Y Sekizawa A Okai T Detection and quantification of fetal DNA in maternal plasma by using LightCycler technologyMethods Mol Biol2008 444231238
Not in our library10.1007/978-1-59745-066-9_18
Cited by papers we hold 4
- Efficiency of non-invasive prenatal screening in pregnant women at advanced maternal age · 2021Not checked
- Improving the calling of non-invasive prenatal testing on 13-/18-/21-trisomy by support vector machine discrimination. · 2018Not checked
- Accuracy of non-invasive prenatal testing using cell-free DNA for detection of Down, Edwards and Patau syndromes: a systematic review and meta-analysis · 2016No notice
- WISECONDOR: detection of fetal aberrations from shallow sequencing maternal plasma based on a within-sample comparison scheme · 2013No notice
Reads
Read by people on this page
None yet.
Checked or read by AI through naulon
None yet.
A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.
Are you an author?
Is this your paper?
Claim it to add your note and be paid when agents cite it. Free.