Polarized light based scheme to monitor column performance in a continuous foam fractionation column
Swamy Janakiraman N, Crofcheck Czarena L, Mengüç MP
Journal of Biological Engineering · 2010
doi:10.1186/1754-1611-4-5 (opens in a new tab)
We email you when a new notice or a question about this paper appears.
Abstract
<p>Abstract</p> <p>Background</p> <p>A polarized light scattering technique was used to monitor the performance of a continuously operated foam fractionation process. The <it>S</it><sub>11 </sub>and <it>S</it><sub>12 </sub>parameters, elements of the light scattering matrix, combined together (<it>S</it><sub>11</sub><it>+S</it><sub>12</sub>) have been correlated with the bubble size and liquid content for the case of a freely draining foam. The performance of a foam fractionation column is known to have a strong dependence on the bubble size distribution and liquid hold up in foam. In this study the enrichment is used as a metric, representative of foam properties and column performance, and correlated to the <it>S</it><sub>11</sub><it>+S</it><sub>12 </sub>parameter.</p> <p>Results</p> <p>Three different superficial gas velocities (6.9, 7.5, and 10.6 cm/min) and four different pH values (4.8, 5.5, 6.5, and 7.5) are tested for the foam fractionation of a dilute solution of bovine serum albumin (0.1 mg/ml). As a result, at scattering angle of 125° the magnitude of <it>S</it><sub>11</sub><it>+S</it><sub>12 </sub>is higher as the pH increases. When the bubble sizes are small with a larger liquid content, the foam is strongly back scattering resulting in lower values of <it>S</it><sub>11</sub><it>+S</it><sub>12 </sub>(at 125°) at pH = 4.8. The light scattering data and the enrichment values are measured over a period of 90 minutes and correlated using a linear model. The predictive power of the model was found to be statistically significant.</p> <p>Conclusion</p> <p>The time average <it>S</it><sub>11</sub><it>+S</it><sub>12 </sub>shows a direct proportionality with the enrichment value, indicating that polarized light should be a valuable technique for monitoring foam fractionation columns. Additional knowledge of the nature of dependence between foam properties and <it>S</it><sub>11</sub><it>+S</it><sub>12 </sub>combined with models relating the enrichment to the bubble size and liquid hold up is needed to develop an accurate diagnostics tool for monitoring enrichment utilizing <it>S</it><sub>11</sub><it>+S</it><sub>12 </sub>measurements.</p>
Abstract licence: CC BY-NC-ND
Reads
Read by people on this page
None yet.
Checked or read by AI through naulon
None yet.
A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.
Are you an author?
Is this your paper?
Claim it to add your note and be paid when agents cite it. Free.