Gel- based proteomics is one of the most versatile methods for fractionating protein complexes. Among these methods, two dimensional- polyacrylamide gel electrophoresis (2-DE) represents a mainstay orthogonal approach, which is popularly used to simultaneously fractionate, identify, and quantify proteins when coupled with mass spectrometric identification or other immunological tests. Although 2-DE was first introduced more than three decades ago, several challenges and limitations to its utility still exist. This review discusses the principles of 2-DE as well as both recent methodological advances and new applications.

Full text

From PubMed Central, U.S. National Library of Medicine, as current on Oct 23, 2026. Paragraph numbers are ours, so an answer can point at one.

Introduction

Two dimensional polyacrylamide gel electrophoresis (2-DE) is considered a powerful tool used for separation and fractionation of complex protein mixtures from tissues, cells, or other biological samples. It allows separation of hundreds to thousands of proteins in one gel. This technique became more popular and comprehensive after the prime advances and high resolution 2-DE modification. Actually, the modification established by O’Farrell allowed 2-DE technique to resolve up to 5000 protein- representing spots in an even 2 dimensional distribution and enabled precise separation of protein spots with high accuracy.

2-DE technique is deemed to be one of the leading powers in the expansion of proteomics and protein studies. It provides the first step for further analysis of the differentially regulated protein spots using mass spectrometry and western blotting. The use of 2-DE has been effectively defined in many cases to disclose both physiological mechanisms and proteins associated with clinical pathologies that can aid in the discovery of biomarkers.

Concept of 2-DE

2-DE consists mainly of two steps of separation; first dimension and second dimension. In the first dimension, protein molecules are resolved depending on their isoelectric point (pI). Separation of proteins under a pH gradient allows intense band recovering using various tactics such as immobilized gradient electrophoresis (IPEG), isoelectric focusing (IEF), or non-equilibrium pH gradient electrophoresis (NEPHGE). In the second dimension, protein separation is performed based on molecular weight using SDS Laemmli or Tris-Tricine buffers. Due to the fact that it is improbable that different protein molecules may have the same physicochemical properties (pI and MW), proteins are efficiently separated by 2-DE rather than 1D-SDS PAGE. A prominent merit of 2-DE is that the resolution acquired during the first dimensional separation is not missed in the second electrophoresis when IEF gel strip is connected to the SDS- PAGE gel.

Applications and utilities of 2-DE

2-DE is a powerful and widely used method for analysis of complex protein mixtures with exceptional ability to separate thousands of proteins at once. It provides direct visual confirmation of changes in protein/post-translational modifications (PTMs) abundance, thus providing early justification for downstream analytical steps through detecting post- and co-translational modifications, which cannot be predicted from the genomic sequence. Other applications of 2-DE include whole proteome analysis, cell differentiation, detection of biomarkers and disease markers, drug discovery, cancer research, bacterial pathogenesis, purity checks, microscale protein purification, and product characterization.

Robustness

During the last few years, several methodological improvements have contributed to increase the robustness of 2-DE workflows. The use of immobilized isoelectric focusing (IEF) strips, ampholytes- based buffers, highly sensitive dyes, and gel imaging software made the variability most likely from upstream process such as protein loss during extraction. In a recent multi-laboratory study on the feasibility of 2-DE, it is reported that 70-93% of spots were detected with coefficient of variation (CVs) less than 20% within same laboratory researchers. On the other hand, 72% of spots showed CVs with less than 20% across laboratories. This finding proves the feasibility and the robustness of 2-DE. Moreover, 2-DE becomes less variable when multiplexing electrophoresis developed. Differentially labeled samples run at the same time minimized the possibility of artifacts resulted from technical errors. Finally, the recent improvements of the gel image analysis minimized the former high percentage of spot identification failure estimated to reach 60% which considered one of the major contributors to variability seen with 2-DE.

Visualized mapping analysis

One of the unique features of 2-DE is its ability to resolve intact full-length proteins (up to 5000 protein) in a single gel. This includes visualized detection of the physico-chemical properties such as MW and pI with possible quantification based on the spot intensity. Proteins of interest could be characterized via peptide mass finger printing or when probed with antibodies. Moreover, 2-DE allows separation and identification of PTMs and protein isoforms (Figure 1). In several cases, PTMs could be recognized by horizontal or vertical shifting of a protein spot as these modifications usually change the protein MW and pI.

Compatible platform for further analysis

2-DE gel easily and efficiently couples with many other analysis and biochemical techniques. Thus, it provides a compatible platform for subsequent analysis. For example, stained gels can be followed by spot excision, destaining, protein extraction, digestion, and analysis of the tryptic peptides by mass spectrometry. Although coomassie blue could be reversibly destained and compatible with mass spectrometry, silver staining, it is not compatible because of the usage of formaldehyde or glutaraldehyde during the fixing and sensitization step that results in lysine residue cross-linking within the protein chain interfering MS analysis and thus will hinder trypsin digestion. Various modifications in the silver nitrate stain approach were performed to overcome this drawback. Compatibility of 2-DE includes bottom-up proteomics to identify proteins and characterize their amino acid sequences or alternatively proceeded by the top-down proteomics (shotgun) in which the crude proteins extract is digested directly for analysis. In another powerful combination, antibody- based analysis could be coupled before or after 2-DE. For instance, immune-affinity purification can be used to pre-fractionate a protein of interest prior to running 2-DE such as phosphorylated or ribonucleoproteins. Most commonly, 2-DE fractionated proteins are subjected to either in-gel digestion to prepare tryptic peptides for mass spectrometric analysis or gels are validated for protein of interest using western blotting.

Low reproducibility

In the traditional method of the first dimension IEF, the carrier ampholytes is utilized to build pH gradient. The carrier ampholytes-based pH gradient made from soft unsupported tube gels (typically 4% acrylamide) is not stable. There is batch to batch variability and prone to cathodic drift (a progressive loss of basic proteins during long running of electro-focusing under electric field), leading to low reproducibility and requiring careful monitoring of electric field. Replacement of carrier ampholyte-based pH gradient in tube gel with the immobilized pH gradients (IPG) was the key development in increasing the reproducibility of 2-DE.

Difficulty in separating hydrophobic and extremely acidic or basic proteins

Different types of proteins can always be missing, due to the difficulty in separating membrane- bound (hydrophobic) and extreme proteins. Notably, highly acidic or basic proteins are neither easily extracted nor solubilized. This difficulty in extraction relies mainly on the solubilization power of the buffer used in the IEF step. Many efforts have been performed for better solubilization of membrane proteins using different chaotropes or detergents. For instant, Triton X- 114 and CHAPS showed a powerful recovering power towards hydrophobic proteins on 2-DE when tested immunologically. Another study reported the use of cationic detergent benzyldimethyl-n-hexadecylammonium chloride to improve resolving hydrophobic proteins with GRAVY index as low as 0.56. Similar improvement was reported when using detergents such as DHPC and 1,4-dithioethanol. Although solubilization of wide range of proteins could be achieved using denaturating solution (Urea and Thiourea) and zwitterionic detergents (SB 3–10), resistance of certain proteins still remains a built-in problem.

Narrow dynamic range of 2-DE

Low dynamic range of proteins is one of the challenging problems encountered during 2-DE. Highly abundant peptides mask low abundant ones, which may be reflective of low abundant proteins. Moreover, the visualization of faint protein spots (low abundant) separated on 2-DE gels is also governed by staining sensitivity. For example, classic coomassie has a narrow dynamic range with detection limit of only about 100 ng. Colloidal coomassie is relatively higher in sensitivity with detection limit 10 ng. The dynamic range could be increased to a detection level below 1 ng with the availability of highly sensitive silver-staining method and a diversity of fluorescence dyes such as SYPRO-Ruby and Deep purple flurophore dyes (Figure 2). Therefore, using sensitive stain increases protein sample dynamic range, leads to successful gel imaging, and finally leads to successful mass spectrometric identification and immunological validation. Alternatively, depletion of highly abundant proteins such as albumin and hemoglobin significantly improves the dynamic range of 2-DE by allowing better focusing and mass spectrometric picking (see Prefractionation, enrichment, and depletion prior to 2-DE section). Therefore, the limited detection sensitivity of 2-DE does not cope with the actual dynamic range of protein concentration in cell and tissue extracts, or biological fluids. Other solution to overcome the dynamic range problem is to load more protein sample and using a giant 2-DE gel (24 cm). However, this approach could result in production of overcrowded images with non well-separated spots.

Low throughput and labor- intensiveness

2-DE is labor-intensive and has a relative low throughput. The throughput of 2-DE is adequate for many small-scale basic research studies, but it may present a serious obstacle for projects that involve screening of a large number of clinical samples. Furthermore, 2-DE requires skills and experience to counteract any possible trouble shooting due to the procedural artifacts. Much care should be considered to minimize the variations during sample processing that lasts up to 3 days in larger gels.

2D- DIGE

The development of image technology has introduced differential imaging gel electrophoresis (DIGE) technique. This method was designed in an attempt to increase sensitivity and reproducibility of 2-DE using multiplexed fluorescent dyes- labeled protein samples. 2D-DIGE is based mainly on running more than one sample (maximum 3 samples) on a single gel at once to address the issue of gel-to gel variability. In this technique, different fluorescent cyanine (Cy) dyes are used for labeling proteins from different samples. After mixing these samples in equal ratio and running them together as one sample, same protein from different samples migrates to the same position on the 2D gel where it could be easily explored and differentiated by the different fluorophore-labeled dye and imaged to calculate its abundance. 2D-DIGE is an important tool, especially for clinical laboratories involved in the determination of protein expression levels and disease biomarker discovery. When absolute biological variation between samples is the main objective, as in biomarker discovery, 2D-DIGE is one of the methods of choice.

Prefractionation, enrichment, and depletion prior to 2-DE

Protein sample prefractionation before 2-DE has been implemented to reduce sample complexity. As a result, the low abundance proteins present in these fractions will be clearly represented in 2-DE. Proteins identified in the prefractionated samples have a higher number of peptides. Moreover, low molecular weight proteins can be clearly detected when sample complexity is reduced. Prefractionation ultimately increases loading capacity of samples onto the 2-DE gel and leads to better resolution, visualization and identification. Sample prefractionation can be performed in several different ways, broadly subdivided into three levels: cellular, subcellular and protein subfractionation. For example, cellular extraction is a generalized approach to screen the whole proteome of a given sample. An extraction buffer containing urea and thiourea with NP-40 usually recovers most proteins. In subcellular prefractionation, a density gradient (isopycnic) centrifugation method, or alternatively tissue strainers and buffers approach is used to homogenate a given tissue followed by using selective solvents to dissolve mitochondrial, ER-golgi, or nuclear proteins. Protein subfractionation based on its physico-chemical properties is another level of fractionation. This method could be used to fractionate proteins based on their charge such as strong cation exchange (SCX) method or based on their pI such as Liquid phase IEF Zoom® prefractionator. Enrichment of protein of interest that exists in the sample in low abundance such as phosphorylated proteins (represents 3-4%) might be essential before 2-DE. For example, in one of our experiments to characterize tyrosine phosphorylated glomerular proteins related to slit diaphragm, samples were immunoprecipitated using protein A- Sepharose then subjected to 2-DE. Depending on the nature of the sample, biological fluids such as plasma and urine may require removal of specific proteins (albumin or hemoglobin) to increase the resolution of separation before 2-DE. On the downstream mass spectrometric level, the excess of highly tryptic peptides generated from these abundant proteins bias the identification towards these proteins on the expense of lower abundant ones. In contrast, depletion increases peptides capture possibilities of low abundant proteins.

Blue native Gel electrophoresis for membrane proteins studies

Blue-Native polyacrylamide gel electrophoresis (Blue Native PAGE) was originally introduced by Schagger and von Jagow as a technique for separating enzymatically active membrane protein complexes under mild condition. In this approach, the anionic dye Coomassie Brilliant Blue G-250 (5% w/v) is mixed with the protein sample prior to gel loading. This dye has the ability to provide negative charges to the surface of the protein. It induces a charge shift that improves solubilization of hydrophobic proteins especially membrane intrinsic electron/proton transfer complexes in mitochondria providing a global analysis of membrane proteomics. The dye binds to protein complexes and both migrate during electrophoresis. Finally, the gels are stained with coomassie dye again prior to mass analysis. A recent implementation for this technique was fruitful in identifying individual compounds within protein complexities of inflammasomes and integrin and histone complexes in placenta. In addition to its ability to unveil protein complexities, this methodology allows better separation of hydrophobic proteins (membrane proteins) as well.

2-DE for post translational modifications (PTMs)

The analysis of protein post-translational modifications (PTMs) has become an important topic for the study of cell biology, disease treatment, and disease prevention. 2-DE provides a direct observation of protein PTMs in gels as well as its relative abundance. Publicly available web-based tools such as ProMoST and JVirGel could be used for that purpose. In addition, specific staining dyes for PTM monitoring were developed and became widely applied in the proteome studies. In phosphoproteome research, molecular Probes, Pro-Q® Diamond phosphoprotein gel stain is a breakthrough technology that provides a precise method for selectively staining phosphoproteins in polyacrylamide gels. Similarly, for glycoproteomics, commercially available fluorescent dye; Lissamine rhodamine B sulfonyl hydrazine (LRSH) was introduced to specifically stain the glycoproteins. This stain relays on periodate/Schiff base mechanism. Unlike conventional methods used for the characterization of PTMs such as the enrichment strategies either with antibodies or immobilized resin, lectin’s binding strategy, or enzymatic based techniques, 2-DE offers an analytical tool with high resolution and high reproducibility by taking the advantage of the well known change in pI and MW induced by many modifications.

First dimension electrophoresis

The first dimension electrophoresis can be performed using ionic substances, which reacts as acid or base and is termed as carrier ampholyte pH gradient. It could be blended and optimized for wide or more restricted pH ranges. Several techniques for IEF could be applied in the first dimension electrophoresis as explained below.

Conventional IEF

The conventional method of IEF depends on the carrier ampholyte where proteins migrate in a solution media until reaching the equilibrium state when its net charge equals to zero. Proteins that are in a pH region below its isoelectric point (pI) will be positively charged and will migrate towards the cathode. As it migrates through a gradient of increasing pH, however, the protein’s overall charge will decrease until the protein reaches the pH region that corresponds to its pI. At this point, the migration ceases. As a result, the proteins become focused into sharp stationary bands with each protein positioned at a point in the pH gradient corresponding to its pI.. Although this conventional method is easy to prepare and do not require much casting equipments, it has a main disadvantage as the ampholytes have some susceptibility to flow towards cathode and this gradient flow usually causes a reduction in the reproducibility.

Immobilized pH gradient (IPG)

Immobilized pH gradient strip (IPG) is an integrated part of polyacrylamide gel matrix fixed on a plastic strip. Co-polymerization of a set of non-amphoteric buffers with different chemical properties is included. A ready- made IPG strips are available with different lengths and pI. Usually, short length IPG strips are used for fast screening while longer one for maximal and comprehensive analysis. Various models of 2- DE gels are shown in Figure 3. A commercial pre-casted acrylamide gel matrix co-polymerized with a pH gradient on a plastic strip results in a stable pH value over the traditional ampholyte method. It has an ability to avoid cationic accumulation and to produce a better-focused protein with less smearing. There are many other advantages of using IPG strips over ampholytes such as reduced cathodic drift, higher mechanical strength as the strips are casted on a plastic backing that minimizing gel breakage, and higher protein loading capacity due to the sample loading method.

Non-equilibrium pH gel electrophoresis (NEPHGE)

Non-equilibrium pH gel electrophoresis (NEPHGE) technique was developed to resolve proteins with basic to extremely high pI (7.0 to 11.0) that cannot be separated by the traditional method. In contrast, IPG method allows the protein molecules to move at different rate across the gel based on the charge and the volt hours setting that determine speed pattern and reproducibility. A previous study comparing IPG and NEPHGE techniques showed that protein loss was higher in IPG-based method, especially for basic proteins. They found the reproducibility of spots was slightly better in NEPHGE-based method. About half of detected basic protein spots were not reproducible by IPG-based 2-DE, whereas NEPHGE-based method showed excellent reproducibility in the basic gel zone. The reproducibility of acidic proteins was similar in both methods.

Second dimension SDS PAGE

This step separates proteins based on their molecular weight using a vertical electrophoretic device with either Laemmli buffer or Tris- Tricine buffer. Instead of loading protein sample within the wells, the first dimension-rehydrated strip is carefully placed on the top of the SDS-PAGE and sealed with agarose. Further technical details are described by Magdeldin et al..

2- DE software analysis

Most of the software analysis workflow starts with either spot detection or image alignment. Examples of currently available software are listed in Table 1. In general, spot detection software (ex. PDQuest and Proteomweaver) sometimes lead to missing some data because of the mismatching error resulted due to shifted spots between gels or spots overlapping. Furthermore, false positive spots are commonly detected due to staining artifacts especially with poor technical skills. To avoid these problems, an alternative processing workflow approaches relay on aligning gel images before processing were developed (ex. Progenesis samespot and Decodon). This method increased the precision of spot detection, raised the accuracy of spot overlying, enabled alignment of several replicates, and saved time. In a practical example illustrated in Figure 4, same gel images of 2 groups were analyzed using PDquest and progenesis samespot software that utilize initial step of spot detection or image alignment, respectively. The result showed inaccuracy of spot detection in the analysis starting with spot detection by detecting many false positive spots. On contrary, precise spots were recognized when gel images where aligned first. This improvement in gel image processing reduced variability between gels and increased the power to detect differentially expressed spots with less effort of manual editing. The key steps of the workflow of most of these automated methods are as following; image quality control, image alignment, spot detection, automatic analysis, editing of spot detection, review the results, statistical analysis, calibration of spots against either a molecular weight ladder or known proteins, spot picking, and importing the protein ID (Figure 5). These automated methods are helpful for gel identification particularly in the quantitative proteomics. They primarily analyze biomarkers by quantifying individual proteins and showing the separation between one or more protein spots on a scanned image of a 2-DE gel. Additionally, they match spots between gels of similar samples. For example, proteomic differences between early and advanced stages of an illness. However, any change or failure in the spot identification may affect the peptide identification in the downstream proteomics as explained later in the challenges section (Challenges in the analysis of the 2-DE images).

2-DE proteome databases

2-DE proteome database websites allow experimental data to be uploaded and disseminated for public. They also help to generate reference maps for normal and diseased cases. These databases display annotated and representative reference map for a variety of cell and tissue types. A list of publicly available databases is found at http://www.expasy.org/ch2d-index.html. The Swiss- 2D PAGE website highlights the World- 2D PAGE database server, the World-2 D PAGE Portal, and the World- 2D PAGE repository, which displays the publication links of each reference map and the experimental condition. So far, it is one of the largest databases for 2-DE. It contains more than 36 different 2-DE reference proteome maps from 7 different species including S. Cerevisiae and E. coli as well as many different human tissues and organs such as kidney and liver. The database annotates protein identification, protein patho-physiological function, physicochemical properties (MW and pl, amino acid composition and peptide masses), and citations. Recently, many other 2-DE reference maps are available online e.g. (http://web.mpiib-berlin.mpg.de/cgi-bin/pdbs/2d-page/extern/index.cgi and http://www.gelbank.anl.gov).

Challenges in the analysis of the 2-DE images

Although bioinformatics software made 2-DE gel analysis much easier, several challenges remain in order to achieve a non-biased, accurate, and reproducible result.

Before software analysis

The key role in a successful computer- based gel imaging relays on the quality of the raw image itself. Therefore, it is necessary to use a high resolution scanner. CCD cameras are time consuming but could be used for several stained gels. laser scanners are more accurate and generate high resolution raw images. In general, image resolution of 100–150 in TIEF format is enough for quantitative analysis. In comparative analysis, it is essential to reproduce replicate gels with minimal noise and background for correct quantification. Certain filters might be applied with care for gel optimization prior to analysis.

During the process of analysis

Differences in the spot positions between gels are major challenging issue in image processing because they impede accurate spot matching. The key step for overcoming spot shifting is to perform a gel image alignment in which certain landmark spots are first pinned between all gels. In a next step, the software tries to align other spots based on these landmarks. However, in some cases, complete alignment could not be obtained if the two patterns are so different. Therefore, in such case, one should avoid excessive manual interventions because this would worsen the reliability of the image control and the reproducibility of the operation between different users. Because of the quantification and the normalization of the spot intensity, one should realize that the relationship between the original protein quantity in the sample and the measured spot intensity is affected by various intervening factors. For example, sample loss occurring during the IEF or while transferring to the second dimension. Given the biochemical diversity of the protein molecules, it is expected that there are some proteins with a nonlinear relation between concentration and intensity. Therefore, one should expect to obtain relatively quantitative results referring to same protein species coming from different samples.

Concluding remarks

Protein separation is a core part of proteomics analysis. 2-DE is a basic and fundamental procedure to fractionate and visualize protein complexes. The 2-DE method is superior to visualize each protein as a spot that can be interpreted by its abundance, location, or even its presence or absence. This visual- based result is in most cases confident. Meanwhile, 2-DE procedures need experience and optimization of skills. With the ongoing development and modifications applied to this sophisticated technique, 2-DE is expected to be less labor, more informative, sensitive, rapid, and easily applied.

Competing interest

The authors declare that they have no competing interest.

Authors’ contributions

SM, SE, YY, BX, YZ, ZZ, IL, EY drafted the manuscript. TY edited and approved the manuscript. All authors read and approved the final manuscript.

References 48

  1. 1.

    O’Farrell PH High resolution two-dimensional electrophoresis of proteinsJ Biol Chem1975 1140074021

    Not in our library

  2. 2.

    Magdeldin S Zhang Y Bo X Yoshida Y Yamamoto T Biochemistry, Genetics and Molecular Biology “Gel Electrophoresis - Principles and Basics”2012 Rijeka, Croatia: INTECH

    Not in our library

  3. 3.

    Anderson NG Matheson A Anderson NL Back to the future: the human protein index (HPI) and the agenda for post-proteomic biologyProteomics2001 11312

    Not in our library10.1002/1615-9861(200101)1:1<3::aid-prot3>3.0.co;2-t

  4. 4.

    Magdeldin S Li H Yoshida Y Enany S Zhang Y Xu B Fujinaka H Yaoita E Yamamoto T Comparison of two dimensional electrophoresis mouse colon proteomes before and after knocking out aquaporin 8J Proteomics2010 1120312040

    Not in our library10.1016/j.jprot.2010.06.010

  5. 5.

    Jungblut PR Seifert R Analysis by high-resolution two-dimensional electrophoresis of differentiation-dependent alterations in cytosolic protein pattern of HL-60 leukemic cellsJ Biochem Biophys Methods1990 114758

    Not in our library10.1016/0165-022x(90)90044-d

  6. 6.

    Wu W Tang X Hu W Lotan R Hong WK Mao L Identification and validation of metastasis-associated proteins in head and neck cancer cell lines by two-dimensional electrophoresis and mass spectrometryClin Exp Metastasis2002 11319326

    Not in our library10.1023/a:1015515119300

  7. 7.

    Enany S Yoshida Y Magdeldin S Bo X Zhang Y Enany M Yamamoto T Two dimensional electrophoresis of the exo-proteome produced from community acquired methicillin resistant Staphylococcus aureus belonging to clonal complex 80Microbiol Res2013 11504511

    Not in our library10.1016/j.micres.2013.03.004

  8. 8.

    Rabilloud T Chevallet M Luche S Lelong C Two-dimensional gel electrophoresis in proteomics: past, present and futureJ Proteomics2010 1120642077

    Not in our library10.1016/j.jprot.2010.05.016

  9. 9.

    Bech-Serra JJ Borthwick A Colome N ProteoRed C Albar JP Wells M Sanchez del Pino M Canals F A multi-laboratory study assessing reproducibility of a 2D-DIGE differential proteomic experimentJ Biomol Tech2009 11293296

    Not in our library

  10. 10.

    Bland AM Janech MG Almeida JS Arthur JM Sources of variability among replicate samples separated by two-dimensional gel electrophoresisJ Biomol Tech2010 1138

    Not in our library

  11. 11.

    Chevalier F Highlights on the capacities of “Gel-based” proteomicsProteome Sci2010 1123

    Not in our library10.1186/1477-5956-8-23

  12. 12.

    Chevallet M Luche S Diemer H Strub JM Van Dorsselaer A Rabilloud T Sweet silver: a formaldehyde-free silver staining using aldoses as developing agents, with enhanced compatibility with mass spectrometryProteomics2008 1148534861

    Not in our library10.1002/pmic.200800321

  13. 13.

    Shevchenko A Wilm M Vorm O Mann M Mass spectrometric sequencing of proteins silver-stained polyacrylamide gelsAnal Chem1996 11850858

    Not in our library10.1021/ac950914h

  14. 14.

    Pinol-Roma S Choi YD Matunis MJ Dreyfuss G Immunopurification of heterogeneous nuclear ribonucleoprotein particles reveals an assortment of RNA-binding proteinsGenes Dev1988 11215227

    Not in our library10.1101/gad.2.2.215

  15. 15.

    Kjaersgard IV Jessen F Two-dimensional gel electrophoresis detection of protein oxidation in fresh and tainted rainbow trout muscleJ Agric Food Chem2004 1171017107

    Not in our library10.1021/jf049573b

  16. 16.

    Gorg A Postel W Domscheit A Gunther S Two-dimensional electrophoresis with immobilized pH gradients of leaf proteins from barley (Hordeum vulgare): method, reproducibility and genetic aspectsElectrophoresis1988 11681692

    Not in our library10.1002/elps.1150091103

  17. 17.

    Gorg A Postel W Gunther S The current state of two-dimensional electrophoresis with immobilized pH gradientsElectrophoresis1988 11531546

    Not in our library10.1002/elps.1150090913

  18. 18.

    Wilkins MR Gasteiger E Sanchez JC Bairoch A Hochstrasser DF Two-dimensional gel electrophoresis for proteome projects: the effects of protein hydrophobicity and copy numberElectrophoresis1998 1115011505

    Not in our library10.1002/elps.1150190847

  19. 19.

    Corthals GL Wasinger VC Hochstrasser DF Sanchez JC The dynamic range of protein expression: a challenge for proteomic researchElectrophoresis2000 1111041115

    Not in our library10.1002/(sici)1522-2683(20000401)21:6<1104::aid-elps1104>3.0.co;2-c

  20. 20.

    Santoni V Rabilloud T Doumas P Rouquie D Mansion M Kieffer S Garin J Rossignol M Towards the recovery of hydrophobic proteins on two-dimensional electrophoresis gelsElectrophoresis1999 11705711

    Not in our library10.1002/(sici)1522-2683(19990101)20:4/5<705::aid-elps705>3.0.co;2-q

  21. 21.

    Zahedi RP Meisinger C Sickmann A Two-dimensional benzyldimethyl-n-hexadecylammonium chloride/SDS-PAGE for membrane proteomicsProteomics2005 1135813588

    Not in our library10.1002/pmic.200401214

  22. 22.

    Babu GJ Wheeler D Alzate O Periasamy M Solubilization of membrane proteins for two-dimensional gel electrophoresis: identification of sarcoplasmic reticulum membrane proteinsAnal Biochem2004 11121125

    Not in our library10.1016/j.ab.2003.10.024

  23. 23.

    Pasquali C Fialka I Huber LA Preparative two-dimensional gel electrophoresis of membrane proteinsElectrophoresis1997 1125732581

    Not in our library10.1002/elps.1150181413

  24. 24.

    Rabilloud T Adessi C Giraudel A Lunardi J Improvement of the solubilization of proteins in two-dimensional electrophoresis with immobilized pH gradientsElectrophoresis1997 11307316

    Not in our library10.1002/elps.1150180303

  25. 25.

    Falvo S Di Carli M Desiderio A Benvenuto E Moglia A America T Lanteri S Acquadro A 2-D DIGE analysis of UV-C radiation-responsive proteins in globe artichoke leavesProteomics2011 11344860

    Not in our library10.1002/pmic.201100337

  26. 26.

    Semaan SM Sang Q-XA Prefractionation enhances loading capacity and identification of basic proteins from human breast cancer tissuesAnal Biochem2011 118

    Not in our library10.1016/j.ab.2010.12.010

  27. 27.

    Stasyk T Huber LA Zooming in: fractionation strategies in proteomicsProteomics2004 1137043716

    Not in our library10.1002/pmic.200401048

  28. 28.

    Boisvert FM Lam YW Lamont D Lamond AI A quantitative proteomics analysis of subcellular proteome localization and changes induced by DNA damageMol Cell Proteomics2010 11457470

    Not in our library10.1074/mcp.m900429-mcp200

  29. 29.

    Cascio S Zhang L Finn OJ MUC1 protein expression in tumor cells regulates transcription of proinflammatory cytokines by forming a complex with nuclear factor-kappaB p65 and binding to cytokine promoters: importance of extracellular domainJ Biol Chem2011 114224842256

    Not in our library10.1074/jbc.m111.297630

  30. 30.

    Molloy MP Herbert BR Walsh BJ Tyler MI Traini M Sanchez JC Hochstrasser DF Williams KL Gooley AA Extraction of membrane proteins by differential solubilization for separation using two-dimensional gel electrophoresisElectrophoresis1998 11837844

    Not in our library10.1002/elps.1150190539

  31. 31.

    Zhu K Yan F O’Neil KA Hamler R Lubman DM Lin L Barder TJ Proteomic analysis using 2-D liquid separations of intact proteins from whole-cell lysatesCurr Protoc Protein Sci2004 11Unit 23 23

    Not in our library10.1002/0471140864.ps2303s34

  32. 32.

    Zhang Y Yoshida Y Nameta M Xu B Taguchi I Ikeda T Fujinaka H Mohamed SM Tsukaguchi H Harita Y Yaoita E Yamamoto T Glomerular proteins related to slit diaphragm and matrix adhesion in the foot processes are highly tyrosine phosphorylated in the normal rat kidneyNephrol Dial Transplant2010 1117851795

    Not in our library10.1093/ndt/gfp697

  33. 33.

    Karlsson K Cairns N Lubec G Fountoulakis M Enrichment of human brain proteins by heparin chromatographyElectrophoresis1999 1129702976

    Not in our library10.1002/(sici)1522-2683(19991001)20:14<2970::aid-elps2970>3.0.co;2-p

  34. 34.

    Fountoulakis M Takacs MF Berndt P Langen H Takacs B Enrichment of low abundance proteins of Escherichia coli by hydroxyapatite chromatographyElectrophoresis1999 1121812195

    Not in our library10.1002/(sici)1522-2683(19990801)20:11<2181::aid-elps2181>3.0.co;2-q

  35. 35.

    Schagger H von Jagow G Blue native electrophoresis for isolation of membrane protein complexes in enzymatically active formAnal Biochem1991 11223231

    Not in our library10.1016/0003-2697(91)90094-a

  36. 36.

    Kofoed EM Vance RE Blue native polyacrylamide gel electrophoresis to monitor inflammasome assembly and compositionMethods Mol Biol2013 11169183

    Not in our library10.1007/978-1-62703-523-1_13

  37. 37.
  38. 38.

    Salzano AM Novi G Arioli S Corona S Mora D Scaloni A Mono-dimensional blue native-PAGE and bi-dimensional blue native/urea-PAGE or/SDS-PAGE combined with nLC-ESI-LIT-MS/MS unveil membrane protein heteromeric and homomeric complexes in Streptococcus thermophilusJ Proteomics2013 11240261

    Not in our library10.1016/j.jprot.2013.09.007

  39. 39.

    Halligan BD Ruotti V Jin W Laffoon S Twigger SN Dratz EA ProMoST (Protein Modification Screening Tool): a web-based tool for mapping protein modifications on two-dimensional gelsNucleic Acids Res2004 11W638644

    Not in our library10.1093/nar/gkh356

  40. 40.

    Hiller K Schobert M Hundertmark C Jahn D Munch R JVirGel: calculation of virtual two-dimensional protein gelsNucleic Acids Res2003 1138623865

    Not in our library10.1093/nar/gkg536

All 48 references

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.