Skip to content
naulon
Not checkedNot checked for notices yet.

Combined optical trapping and single-molecule fluorescence

Lang Matthew J, Fordyce Polly M, Block Steven M

Journal of Biology · 2003

doi:10.1186/1475-4924-2-6 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

<p>Abstract</p> <p>Background</p> <p>Two of the mainstay techniques in single-molecule research are optical trapping and single-molecule fluorescence. Previous attempts to combine these techniques in a single experiment – and on a single macromolecule of interest – have met with little success, because the light intensity within an optical trap is more than ten orders of magnitude greater than the light emitted by a single fluorophore. Instead, the two techniques have been employed sequentially, or spatially separated by distances of several micrometers within the sample, imposing experimental restrictions that limit the utility of the combined method. Here, we report the development of an instrument capable of true, simultaneous, spatially coincident optical trapping and single-molecule fluorescence.</p> <p>Results</p> <p>We demonstrate the capability of the apparatus by studying force-induced strand separation of a rhodamine-labeled, 15 base-pair segment of double-stranded DNA, with force applied perpendicular to the axis of the DNA molecule. As expected, we observed abrupt mechanical transitions corresponding to the unzipping of DNA at a critical force. Transitions occurred concomitant with changes in the fluorescence of dyes attached at the duplex ends, which became unquenched upon strand separation.</p> <p>Conclusions</p> <p>Through careful optical design, the use of high-performance spectral notch filters, a judicious choice of fluorophores, and the rapid acquisition of data gained by computer-automating the experiment, it is possible to perform combined optical trapping and single-molecule fluorescence. This opens the door to many types of experiment that employ optical traps to supply controlled external loads while fluorescent molecules report concurrent information about macromolecular structure.</p>

Abstract licence: CC BY

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.