Skip to content
naulon

Not checkedNot checked for notices yet.

Rapid diagnosis of experimental meningitis by bacterial heat production in cerebrospinal fluid

Steinhuber Andrea, Trampuz Andrej, Wittwer Matthias and 1 more

BMC Infectious Diseases · 2007

doi:10.1186/1471-2334-7-116 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

<p>Abstract</p> <p>Background</p> <p>Calorimetry is a nonspecific technique which allows direct measurement of heat generated by biological processes in the living cell. We evaluated the potential of calorimetry for rapid detection of bacterial growth in cerebrospinal fluid (CSF) in a rat model of bacterial meningitis.</p> <p>Methods</p> <p>Infant rats were infected on postnatal day 11 by direct intracisternal injection with either <it>Streptococcus pneumoniae, Neisseria meningitidis </it>or <it>Listeria monocytogenes</it>. Control animals were injected with sterile saline or heat-inactivated <it>S. pneumoniae</it>. CSF was obtained at 18 hours after infection for quantitative cultures and heat flow measurement. For calorimetry, 10 μl and 1 μl CSF were inoculated in calorimetry ampoules containing 3 ml trypticase soy broth (TSB).</p> <p>Results</p> <p>The mean bacterial titer (± SD) in CSF was 1.5 ± 0.6 × 10<sup>8 </sup>for <it>S. pneumoniae</it>, 1.3 ± 0.3 × 10<sup>6 </sup>for <it>N. meningitidis </it>and 3.5 ± 2.2 × 10<sup>4 </sup>for <it>L. monocytogenes</it>. Calorimetric detection time was defined as the time until heat flow signal exceeded 10 μW. Heat signal was detected in 10-μl CSF samples from all infected animals with a mean (± SD) detection time of 1.5 ± 0.2 hours for <it>S. pneumoniae</it>, 3.9 ± 0.7 hours for <it>N. meningitidis </it>and 9.1 ± 0.5 hours for <it>L. monocytogenes</it>. CSF samples from non-infected animals generated no increasing heat flow (<10 μW). The total heat was the highest in <it>S. pneumoniae </it>ranging from 6.7 to 7.5 Joules, followed by <it>L. monocytogenes </it>(5.6 to 6.1 Joules) and <it>N. meningitidis </it>(3.5 to 4.4 Joules). The lowest detectable bacterial titer by calorimetry was 2 cfu for <it>S. pneumoniae</it>, 4 cfu for <it>N. meningitidis </it>and 7 cfu for <it>L. monocytogenes</it>.</p> <p>Conclusion</p> <p>By means of calorimetry, detection times of <4 hours for <it>S. pneumoniae </it>and <it>N. meningitidis </it>and <10 hours for <it>Listeria monocytogenes </it>using as little as 10 μl CSF were achieved. Calorimetry is a new diagnostic method allowing rapid and accurate diagnosis of bacterial meningitis from a small volume of CSF.</p>

Abstract licence: CC BY-NC-ND

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.