No retraction, correction or concern found when last checked on Oct 17, 2026.
An evaluation of R2 as an inadequate measure for nonlinear models in pharmacological and biochemical research: a Monte Carlo approach
Andrej-Nikolai Spiess, Natalie Neumeyer
BMC Pharmacology · 2010
Abstract
Background. It is long known within the mathematical literature that the coefficient of determination R2 is an inadequate measure for the goodness of fit in nonlinear models. Nevertheless, it is still frequently used within pharmacological and biochemical literature for the analysis and interpretation of nonlinear fitting to data.
Results. The intensive simulation approach undermines previous observations and emphasizes the extremely low performance of R2 as a basis for model validity and performance when applied to pharmacological/biochemical nonlinear data. In fact, with the 'true' model having up to 500 times more strength of evidence based on Akaike weights, this was only reflected in the third to fifth decimal place of R2. In addition, even the bias-corrected R2adj exhibited an extreme bias to higher parametrized models. The bias-corrected AICc and also BIC performed significantly better in this respect.
Conclusion. Researchers and reviewers should be aware that R2 is inappropriate when used for demonstrating the performance or validity of a certain nonlinear model. It should ideally be removed from scientific literature dealing with nonlinear model fitting or at least be supplemented with other methods such as AIC or BIC or used in context to other models in question.
Full text
From PubMed Central, U.S. National Library of Medicine, as current on Oct 17, 2026. Paragraph numbers are ours, so an answer can point at one.
Background
Fitting nonlinear models to data is frequently applied within all fields of pharmaceutical and biochemical assay quantification. A plethora of nonlinear models exist, and chosing the right model for the data at hand is a mixture of experience, knowledge about the underlying process and statistical interpretation of the fitting outcome. While the former are of somewhat individual nature, there is a need in quantifying the validity of a fit by some measure which discriminates a 'good' from a 'bad' fit. The most common measure is the coefficient of determination R2 used in linear regression when conducting calibration experiments for samples to be quantified. In the linear context, this measure is very intuitive as values between 0 and 1 give a quick interpretation of how much of the variance in the data is explained by the fit. Although it is known now for some time that R2 is an inadequate measure for nonlinear regression, many scientists and also reviewers insist on it being supplied in papers dealing with nonlinear data analysis. Several initial and older descriptions for R2 being of no avail in nonlinear fitting had pointed out this issue but have probably fallen into oblivion. This observation might be due to differences in the mathematical background of trained statisticians and biochemists/pharmacologists who often apply statistical methods but lack detailed statistical insight.
We made the observation that R2 is still frequently being used in the context of performance or validity of a certain model when fit to nonlinear data. R2 is not an optimal choice in a nonlinear regime as the the total sum-of-squares (TSS) is not equal to the regression sum-of-squares (REGSS) plus the residual sum-of-squares (RSS), as is the case in linear regression, and hence it lacks the above interpretation (see Additional File 1, paragraphs 1 & 2). To our observation, there is still a high occurrence in the present literature of all biomedical fields where the validity of nonlinear models is based solely on R2 values, which might be a result of authors or reviewers not being aware of this fallacy. Additionally, almost all of the commercially available statistical software packages (i.e. Prism, Origin, Matlab, SPSS, SAS) calculate R2 values for nonlinear fits, which is bound to unintentionally corroborate its frequent use. A further example is the TableCurve2 D software (Systat, USA) which can fit hundreds of nonlinear models to a given dataset automatically and then rank these by means of R2. Noted 25 years ago by Kvalseth, the user is usually not able to identify which of the eight different definitions of R2 that are commonly being used in the literature is chosen for the analysis output in statistical software (see Additional File 1, Remark 4).
We thus aimed to point out the low performance of R2 and its inappropriateness for nonlinear data analysis by basing our analysis on an extensive Monte Carlo simulation approach. This approach has fundamental advantages in the analysis of nonlinear data analysis and can reveal tendencies within statistical methods by supplying the models and measures in question with thousands of generated datasets.
Creation of the 'true' model
In a first step, we fitted a three-parameter log-logistic model (L3, see Formula 3 below) by nonlinear least-squares to sigmoidal data that was taken from quantitative real-time polymerase chain reaction (qPCR). This yielded a sigmoidal model with the parameters b = -9.90, d = 11.07 and e = 24.75. We used the fitted values of this model and x-values from 10-35 as the 'true' model with sample size n = 26 for the following Monte Carlo simulation. This essentially gave a sigmoidal curve that can be encountered in many different areas of pharmacological/biochemical analysis. Specific to qPCR data, the x-values ("Cycles") are equidistant and not on a log-scale, as often encountered in dose-response analysis. For mathematical details, see Remark 7 in Additional File 1.
Perturbation of data (Monte Carlo Simulation)
Using the fitted values as above, all datapoints were perturbed 2000 times by adding six different magnitudes (very low to high) of homoscedastic noise from a gaussian distribution with mean = 0 and standard deviations = 0.01, 0.02, 0.05, 0.1, 0.2 or 0.4. The noise of the data was therefore between 0.1% and 4% of the data range. This way, for each of six different settings (determined by different standard deviations), we obtained 2000 new data sets of sample size n = 26 with true model L3. For each of these data sets, nine different sigmoidal models differing in model type and number of parameters (Formulas 1-9) were fit. For mathematical details, see Remark 7 in Additional File 1.
Formula 1: Five parameter log-logistic model (L5):
Formula 2: Four-parameter log-logistic model (L4):
Formula 3: Three-parameter log-logistic model (L3):
Formula 4: Five parameter logistic model (B5):
Formula 5: Four-parameter logistic model (B4):
Formula 6: Three-parameter logistic model (B3):
Formula 7: Four-parameter Weibull model (W4):
Formula 8: Three-parameter Weibull model (W3):
Formula 9: Five-parameter baroreflex model (baro5):
Calculation of measures for goodness-of-fit
For each simulation, we calculated the following measures for goodness-of-fit:
R2, using the most general definition:
Formula 10:
with RSS = residual sum-of-squares, TSS = total sum-of-squares, y = response values, = fitted values and = the mean of response values. For a more detailed description see Remarks 1-6 in Additional File 1.
We chose to use the adjusted R2 to compensate for possible bias due to different number of parameters:
Formula 11:
with n = sample size and p = number of parameters.
The Akaike Information Criterion (AIC,), a measure that is widely accepted for measuring the validity within a cohort of nonlinear models and frequently used for model selection.
Formula 12:
with p = number of parameters and ln(L) = maximum log-likelihood of the estimated model. The latter, in the case of a nonlinear fit with normally distributed errors, is calculated by
Formula 13:
with x1,..., xn = the residuals from the nonlinear least-squares fit and N = their number.
To provide a fair playing ground, we employed an AIC variant that corrects for small sample sizes, the bias-corrected AIC (AICc):
Formula 14:
with n = sample size and p = number of parameters.
In order to obtain values for the validity of a fit, we used Akaike weights which calculate the weight of evidence for each model within a cohort of models in question:
Formula 15:
with i, k = model numbers, Δi(AIC) = the difference in AIC of each model in comparison to the model with the lowest AIC, subsequently normalized to their sum (denominator).
Also here, we used the bias-corrected AICc for calculating the Akaike weights.
We also chose to employ the Bayesian Information Criterion (BIC), which gives a higher penalty on the number of parameters:
Formula 16:
with p = number of parameters, n = sample size and L = maximum likelihood of the estimated model.
Furthermore, the residual variance as the part of the variance that cannot be accounted for by the model:
Formula 17:
with RSS = residual sum-of-squares, n = sample size and p = number of parameters.
The variance of a least-squares fit is also characterized by the chi-square statistic defined as Formula 18:
where yi = response values, f(xi) = the fitted values and = the uncertainty in the individual measurements yi. We further define the reduced chi-square as a useful measure by
Formula 19:
with ν = n - p (degrees of freedom). If the fitting function is a good approximation to the parent function, then the variances of both should agree well, and the reduced chi-square should be approximately unity. If the reduced chi-square is much larger than 1 (i.e. 10 or 100), it means that one is either overly optimistic about the measurement errors or that one selected an inappropriate fitting function. If reduced chi-square is too small (i.e. 0.1 or 0.01) it may mean that one has been too pessimistic about measurement errors. For this work, models were selected based on reduced chi-square by being closest to 1.
Analysis of the simulation data
Two different approaches were pursued within the Monte Carlo simulated data. To reveal general tendencies, we averaged the values of R2adj, AICc, BIC, residual variance and reduced chi-square from all 2000 simulated data sets (for each noise magnitude and each of the 9 models). To permit a more detailed insight for each simulation and to compare the measures on the single model level, we selected the best model in each iteration based on the highest R2adj, lowest AICc, lowest BIC, lowest residual variance and smallest difference to unity for reduced chi-square. For the latter, we used as the measurement uncertainty the a priori known squared standard deviation from the homoscedastic noise that was applied to produce the random data of the Monte Carlo simulations.
Finally, we calculated the percentage of selecting the 'true' model L3 in all iterations.
Code for the simulations
All simulations were conducted using R, a well reputed and open-source statistical programming language. Nonlinear curve fitting was done by using functionality from the R package qpcR. The commented code for the simulations can be obtained from Additional File 2.
Results and Discussion
Figure 1 illustrates the simulated data that was used as the basis of our analysis. Starting from the fitted values of a three-parameter log-logistic model (L3), different amounts of homoscedastic gaussian noise were added to the fitted values resulting in the point clouds as shown. We analyzed six different magnitudes of gaussian noise in total, from low noise (s.d. = 0.01, 0.02), medium noise (s.d. = 0.05, 0.1) to high noise (s.d. = 0.2, 0.4; see Figure 1) with a total of 2000 simulations per noise setup.
Fitting all nine different sigmoidal models to the fitted values of the 'true' model (L3) is depicted in Figure 2A, demonstrating the differences against this model when noise is completely lacking. All logistic models fit well in this context, which tallies with the observation of five-parameter models exhibiting increased performance due to accomodating asymmetrical structures. Visualized also by a residuals plot that delivers higher resolution of the residuals (Figure 2B), the log-logistic models (L3, L4, L5) provide very small residual values, the logistic models (B3, B4, B5) have higher residual values and the Weibull models (W3, W4) are significantly inferior. This is evident especially in the upper and lower region from the point of inflection.
AICc and adjusted R2adj were compared by averaging the output of all 2000 simulations and for three different magnitudes (low, middle, high) of homoscedastic gaussian noise (Figure 3). Not surprisingly, the R2adj values decrease and the AICc values increase with higher noise (left to right). But the major problem in the use of R2 is clearly evident within the simulation setup: the AIC differences (delta-AIC) between some models can be 78 (compare L3 and B3 models at s.d. = 0.02), which when transferred to Akaike weights result in a weight of evidence 16 (!) orders of magnitude in favor of L3. One might be inclined to say that this is major evidence for the first model being in favor of the second one, but in respect to the corresponding R2adj values, only the fourth decimal place is affected. This tendency is also found for higher noise, despite AICc values increasing and R2adj values decreasing. Even in the presence of relatively high noise (s.d. = 0.4), at least for the simulation setup in this work, R2adj would hardly drop below 0.99. Comparing the Akaike weight of the models with the R2adj values in Table 1 shows the strong discrepancy in scale changes of these two measures when comparing a cohort of different models.
However, differences in scale changes would be unimportant if the direction of change is always reciprocally (i.e. a lower AICc always corresponding with a higher R2adj). As can be deduced from Table 1, this is not always the case. Using the averaged measures from the simulations, R2adj and AICc did not always behave reciprocally. For instance, at s.d. = 0.05, 0.2 and 0.4 the 'true' model L3 has a lower AICc than L5 (and ~ 8 times more weight of evidence by Akaike weights), but R2adj values are also lower in the fifth to eighth decimal place. Using R2adj for model selection would therefore have resulted in a model which is clearly not in favor based on Akaike weights.
On the averaged values, BIC essentially shows the same characteristics as AICc. Interestingly, the residual variance is higher in the 'true' model L3 than L5 for most noise regimes (although also only in the third to eighth decimal place), indicating this to be a relatively unfavorable measure. Likewise, the reduced chi-square exhibited a tendency to be closest to unity for higher parameter models (L4, L5, B5) with increasing noise, here also only affected in the third decimal place.
To acquire more detailed insight into the performance of the different measures in respect to the selection of the best model and in dependence of different noise magnitudes, we selected the best model of each iteration by each of the measures. This approach can reveal features that are not evident when calculating the averaged measures of all simulations. We summarized the outcome of this analysis as a heatmap display in Figure 4 and as 'model selection frequency' in Table 2. Within each image plot, the selected models are shown with the same colour coding as in Figures 1, 2 and 3. For the low (s.d. = 0.02) and medium (s.d. = 0.1) setup, R2adj, residual variance (resVar) and reduced chi-square performed not optimally, selecting the true model L3 only in 28-43% of the iterations. Both measures exhibited a severe bias in the selection of models with a higher number of parameters (L4, L5, B5, baro5). It is interesting to note that although R2adj and the residual variance 'correct' against the number of parameters, there is no positive effect on the ability to select the 'true' model. This may be due largely to the setup in this work which features a relatively high sample size (n = 26) compared to the number of parameters (p = 3-5) and leaves the denominator n - p in both measures relatively unaffected. In contrast, both AICc and BIC performed superior in the selection of the 'true' model L3 at these magnitudes of noise with over 80% of all iterations, but with a slight bias to models with a lower number of parameters at medium noise. At high noise (s.d. = 0.4, corresponding to 4% noise of the data range) the performance of all measures decreased markedly, most probably from the effect of the simulated data losing the structural features typical of the L3 model when high noise is added. Despite this negative trend, AICc and BIC displayed increased performance even at high noise. The two measures selected also a significant number of iterations (about 40%) of other models with the same number of parameters (B3, W3), which might be an indication for a small bias to lower parametrized models. Consequently, and based on the analysis of a sigmoidal nonlinear setup as described here, we feel compelled to give the following summary:
1) The use of highly inferior nonlinear models is reflected only in the third or fourth decimal place of R2 and thus the description of single models when using R2 is not meaningful, as this measure tends to be uniformly high when a set of models is inspected. This has also been noted by others. Additionally, R2 and even its 'bias-corrected' counterpart R2adj are severely biased in favor of models with more parameters when it comes to model selection. The same accounts for the residual variance, which is also commonly used. AICc and BIC do not exhibit this bias and provide a much clearer picture and improved performance when it comes to selecting the 'true' model. The Akaike weights are especially useful in obtaining an overview of the weight of evidence of one model over the other, which is impossible with the per se high R2 values. This approach requires anyhow that it is mandatory to supply several models in question.
2) In a background of low and medium experimental noise, R2adj and AICc selected different models with AICc selecting the 'true model' twice as often (82.2% versus 43%). This finding emphasizes the importance of this measure in nonlinear model selection. At a high noise level rarely encountered in the modelling of pharmacological/biochemical data (4% of data range), AICc still performed superior to R2adj. These results tempt us to conclude that the degree of freedom term n - p in the denominator of the residual variance and R2adj is not sufficient alone to compensate the effect of the number of increasing parameters. The same seems to be the case for the reduced chi-square, which is also frequently used for model selection purposes.
In this work we show that R2 is an inappropriate measure when used in the field of nonlinear fitting. Efforts have been made to develop R2-like measures for the most common nonlinear regression models, but here we focused on the inadequateness of its use by using a data perturbation approach and comparing its performance in comparison to AICc, BIC, residual variance and reduced chi-square. Model selection in nonlinear statistical literature is usually divided into the frequentist methods, for example F-tests on the residual variance that are restricted to nested models, or measures from information theory such as AIC which are often used to compare non-nested models. Indeed, it has been shown that the latter approach can often perform better than F-tests. In the field of biochemical and pharmacological literature there is a reasonably high occurrence in the use of R2 as the basis of arguing against or in favor of a certain model. As a result from this work, we would like to advocate that R2 should not be reported or demanded in phamacological/biochemical literature when discussing nonlinear data analysis. Authors as well as reviewers should be aware that demonstrating the validity of single nonlinear models by using solely R2 is not state-of-the-art and should be replaced or supplemented by AIC/AICc/BIC values (or their corresponding weights of evidence) of several possible models that are in question. The latter will give the dedicated reader the possibility to obtain information about how much a certain model is in favor over others, a feature that will not be evident by minor changes in R2 which tends to be uniformly high and is rarely affected more than in the third or fourth decimal place.
Conclusions
Although frequently being used in the present pharmocological/biochemical literature for describing the validity of a nonlinear fit, R2 is an unfavorable measure that is rarely affected more than in the third or fourth decimal place, even in scenarios with highly inferior models. Our Monte Carlo simulations have shown that AIC, AICc or BIC perform significantly better in this respect so that authors as well as reviewers should be aware of this issue and refrain from using or asking for R2 values when nonlinear models are under investigation.
Competing interests
The authors declare that they have no competing interests.
Authors' contributions
ANS conducted the simulations and wrote the manuscript. NN helped in drafting the manuscript and developed the statistical workflow. All authors read and approved the final manuscript.
References 22
- 1.
Montgomery DC Peck EA Vining GG Introduction to Linear Regression Analysis2006 Wiley & Sons, Hoboken
Not in our library
- 2.
Juliano SA Williams FM A comparison of methods for estimating the functional response parameters of the random predator equationJ Anim Ecol1987 56641653
Not in our library10.2307/5074
- 3.
Miaou SP Lu A Lum HS Pitfalls of using r-squared to evaluate goodness of fit of accident prediction modelsTransportation Research Record #15421996 613
Not in our library10.3141/1542-02
- 4.
Willet JB Singer JD Another cautionary note about R-square: Its use in weighted least-squares regression analysisAmer Stat1988 42236238
Not in our library10.2307/2685031
- 5.
Anderson-Sprecher R Model comparisons and R-squareAmer Stat1994 48113117
Not in our library10.2307/2684259
- 6.
Nagelkerke NJD A note on a general definition of the coefficient of determinationBiometrika1991 78691692
Not in our library10.1093/biomet/78.3.691
- 7.
Magee L R2 measures based on Wald and likelihood ratio joint singnificance testsAmer Stat1990 44250253
Not in our library10.2307/2685352
- 8.
Kvalseth TO Cautionary note about R2Amer Stat1985 39279285
Not in our library10.2307/2683704
- 9.
Bates DM Watts DG Nonlinear regression analysis and its applications1988 1New York, John Wiley & Sons
Not in our library
- 10.
Akaike H Information theory and an extension of the maximum likelihood principleProc 2nd Inter Symposium on Information Theory1973 267281
Not in our library
- 11.
Akaike H A new look at the statistical model identificationIEEE Transaction on Automatic Control1974 19716723
Not in our library10.1109/tac.1974.1100705
- 12.
Akaike H On the likelihood of a time series modelThe Statistician1978 27217235
Not in our library10.2307/2988185
- 13.
Burnham KP Anderson DR Model selection and inference: a practical information-theoretic approach2003 2Springer Verlag, New York, USA
Not in our library
- 14.
Wagenmakers EJ Farrell S AIC model selection using Akaike weightsPsych Bull & Review2004 11192196
Not in our library10.3758/bf03206482
- 15.
Schwarz G Estimating the dimension of a modelAnn Stat1978 6461464
Not in our library10.1214/aos/1176344136
- 16.
Bevington PR Robinson DK Data Reduction and Error Analysis for the Physical Sciences2003 Chapter 113McGraw-Hill, New York
Not in our library
- 17.
The R project homepagehttp://www.r-project.org
Not in our library
- 18.
Ritz C Spiess AN qpcR: an R package for sigmoidal model selection in quantitative real-time polymerase chain reaction analysisBioinformatics2008 2415491551
Not in our library10.1093/bioinformatics/btn227
- 19.
Gottschalk PG Dunn JR The five-parameter logistic: A characterization and comparison with the four-parameter logisticAnal Biochem2005 3435465
Not in our library10.1016/j.ab.2005.04.035
- 20.
Zeng QC Zhang E Tellinghuisen J Univariate calibration by reversed regression of heteroscedastic data: a case studyThe Analyst2008 13316491655
Not in our library10.1039/b808667b
- 21.
Cameron AC Windmeijer FAG An R-squared measure of goodness of fit for some common nonlinear regression modelsJ Econometrics1997 77329342
Not in our library10.1016/s0304-4076(96)01818-0
- 22.
Glatting G Kletting P Reske SN Hohl K Ring C Choosing the optimal fit function: comparison of the Akaike Information Criterion and the f-testMed Phys2007 3442854292
Not in our library10.1118/1.2794176
Cited by papers we hold 7
- Calibration of the BMP280 and ESP-12S Based Wireless Atmospheric Pressure Measure Equipment Using a Pressure Chamber · 2021Not checked
- Moore's Law revisited through Intel chip density. · 2021Not checked
- Effect of Mathematical Modeling and Fitting Procedures on the Assessment of Critical Speed and Its Relationship With Aerobic Fitness Parameters · 2021Not checked
- Empirical models for anatomical and physiological changes in a human mother and fetus during pregnancy and gestation. · 2019Not checked
- Two-component latency distributions indicate two-step vesicular release at simple glutamatergic synapses · 2018Not checked
- Evidence for Male Horn Dimorphism and Related Pronotal Shape Variation in Copris lunaris (Linnaeus, 1758) (Coleoptera: Scarabaeidae, Coprini) · 2018Not checked
- Rapid evolution of metabolic traits explains thermal adaptation in phytoplankton · 2015No notice
Reads
Read by people on this page
None yet.
Checked or read by AI through naulon
None yet.
A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.
Are you an author?
Is this your paper?
Claim it to add your note and be paid when agents cite it. Free.