Skip to content
naulon

Not checkedNot checked for notices yet.

Breath octane and acetaldehyde as markers for acute respiratory distress syndrome in invasively ventilated patients suspected to have ventilator-associated pneumonia

Nanon F.L. Heijnen, Laura A. Hagens, Frederik-Jan van Schooten and 8 more

ERJ Open Research · 2022

doi:10.1183/23120541.00624-2021 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

Rationale The concentration of octane and acetaldehyde in exhaled breath has good diagnostic accuracy for acute respiratory distress syndrome (ARDS). We aimed to determine whether breath octane and acetaldehyde are able to distinguish the presence and absence of ARDS in critically ill patients suspected to have ventilator-associated pneumonia (VAP). Methods This is a secondary analysis of a prospective observational study into exhaled breath analysis using gas chromatography–time-of-flight mass spectrometry. Difference in the relative abundance of octane and acetaldehyde in exhaled breath was compared between patients with and without ARDS using the Mann–Whitney U-test and the association was quantified using logistic regression. The discriminative accuracy of octane and acetaldehyde, alone or in combination, was calculated using the area under the receiver operating characteristic curve (AUROCC). Results We included 98 patients, of whom 32 had ARDS and 66 did not. The area under the acetaldehyde peak was higher in patients with ARDS (p=0.03), and associated with the presence of ARDS (OR 1.06 per 100 000 count change, 95% CI 1.02–1.13 per 100 000 count change; p=0.01). A combined model with octane and acetaldehyde showed a high specificity and low sensitivity (90% and 40.6%, respectively), with a low accuracy (AUROCC 0.65, 95% CI 0.53–0.78). Conclusion Patients suspected to have VAP with ARDS had a higher acetaldehyde concentration in exhaled breath than patients suspected to have VAP without ARDS. However, in this patient population, discrimination of these breath biomarkers for ARDS was poor, indicating the difficulty of translating diagnostic tests between clinical settings.

Abstract licence: CC BY-NC

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.