Skip to content
naulon
Not checkedNot checked for notices yet.

Clinical and functional outcomes of a novel transosseous device to treat rotator cuff tears: A minimum 2-year follow-up

Mehmet Arican, Yalçın Turhan, Zekeriya Okan Karaduman and 1 more

Journal of Orthopaedic Surgery · 2019

doi:10.1177/2309499019875172 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

Purpose: Despite the improvements in the repair equipment techniques of rotator cuff, a gold standard method has not been defined yet and transosseous fixation through deltoid-splitting (mini-open) approach is still regarded as a good option. The primary purpose of this study is to present satisfactory clinical and functional outcomes with a novel transosseous device in full-thickness rotator cuff tear through deltoid-splitting. Materials and Methods: This retrospective study was performed on 70 consecutive patients who underwent surgery by a single surgeon from June 2014 to June 2016 for a full-thickness rotator cuff tear and was managed with a novel transosseous device. Total number of patients, mean age, percentage of male and female patients, mean duration of follow-up, percentage of involvement of the dominant extremity, affected shoulder, and tear size were recorded. Functional and clinical outcomes were assessed baseline and postoperatively at 3 and 6 months and final follow-up using Disabilities of the Arm, Shoulder and Hand (Q-DASH) and Constant-Murley scores. Results: A total of 70 (49 (70%) female, 21 (30%) male) patients whose mean age was 58.66 ± 9.19 (38–77) years were included. The mean surgery time was 35.33 ± 5.34 (28–55) min. The mean follow-up time was 28.31 ± 3.03 (24–36) months. According to the DeOrio and Cofield classification, 15 (21.43%) tears were small, 33 (47.14%) medium, 16 (22.86%) large, and 6 (8.57%) massive. By the final follow-up, the mean Constant-Murley score had significantly improved from 27.67 ± 7.46 (13–41) to 81.25 ± 3.77 (74–87; p = 0.0001) and the Q-DASH score had decreased from 82.34 ± 10.37 (65.91–100) to 10.28 ± 6.88 (0–23.45; p = 0.0001). There were no significant differences in the Constant-Murley or Q-DASH score at baseline–final follow-up between the small, medium, large, and massive tear groups ( p > 0.05). Conclusions: Treatment of full-thickness rotator cuff tear using this novel transosseous device significantly improved functional and clinical scores. However, further long-term prospective randomized multicenter trials involving comparative studies are necessary to confirm these findings.

Abstract licence: CC BY-NC

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.