Skip to content
naulon
Not checkedNot checked for notices yet.

Probe material choice for nuclear magnetic resonance cryoporometry (NMRC) measurements of the nano-scale pore size distribution of unconventional reservoirs

Feng Zhu, Wenxuan Hu, Jian Cao and 3 more

Energy Exploration & Exploitation · 2019

doi:10.1177/0144598718802475 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

Nuclear magnetic resonance cryoporometry is a newly developed technique that can characterize the pore size distribution of nano-scale porous materials. To date, this technique has scarcely been used for the testing of unconventional oil and gas reservoirs; thus, their micro- and nano-scale pore structures must still be investigated. The selection of the probe material for this technique has a key impact on the quality of the measurement results during the testing of geological samples. In this paper, we present details on the nuclear magnetic resonance cryoporometric procedure. Several types of probe materials were compared during the nuclear testing of standard nano-scale porous materials and unconventional reservoir geological samples from Sichuan Basin, Southwest China. Gas sorption experiments were also carried out on the same samples simultaneously. The K GT values of the probe materials octamethylcyclotetrasiloxane and calcium chloride hexahydrate were calibrated using standard nano-scale porous materials to reveal respective values of 149.3 Knm and 184 Knm. Water did not successfully wet the pore surfaces of the standard controlled pore glass samples; moreover, water damaged the pore structures of the geological samples, which was confirmed during two freeze-melting tests. The complex phase transition during the melting of cyclohexane introduced a nuclear magnetic resonance signal in addition to that from liquid in the pores, which led to an imprecise characterization of the pore size distribution. Octamethylcyclotetrasiloxane and calcium chloride hexahydrate have been rarely employed as nuclear magnetic resonance cryoporometric probe materials for the testing of an unconventional reservoir. Both of these materials were able to characterize pore sizes up to 1 μm, and they were more applicable than either water or cyclohexane.

Abstract licence: CC BY

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.