Correlation of transrectal and transabodominal ultrasound measurement of transition zone volume with post-operative enucleated adenoma volume in benign prostatic hypertrophy

Idowu Ajayi, Ademola Aremu, Abimbola Olajide and 3 more

The Pan African Medical Journal · 2013

doi:10.11604/pamj.2013.16.149.2532 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

BACKGROUND: Benign prostatic hyperplasia is a common disease of ageing men worldwide. Though transrectal ultrasonography (TRUS) is the standard in most parts of the world in evaluation of benign prostatic hyperplasia (BPH), it is rarely done in some less developed countries because of non availability of appropriate probes and or specialists. Transabdominal ultrasonography (TAUS) remains the mainstay in these areas. Some controversies still exist in literature about the accuracy of TAUS evaluation of prostatic volume in patients with BPH. This study aimed at comparing the transition zone volume estimation of the prostate on transrectal and transabdominal ultrasound with post-operative enucleated adenoma volume in Nigeria patients with BPH and to suggest better predictor of prostate volume in evaluation of BPH. METHODS: Forty-six (46) patients with lower urinary tract symptoms due to BPH attending the urologic clinic were evaluated ultrasonographically and eventually managed with open surgery (prostatectomy) after due counselling. The post operative samples were weighted using a sensitive top loading weighing balance and converted to volume.Since the specific gravity of the prostate is equivalent to that of water,the weight is the same as volume. RESULTS: Patients' ages ranged between 59 and 90 years with a peak age incidence at seventh decade. Transition Zone (TZ) volume estimation on both transrectal and transabdominal ultrasound showed positive correlation with the post operative enucleated adenoma(r=0.594, p=0.001) but the transrectal method was more accurate. There was no significant relationship between the TZ volume and patients' symptoms(r=0.491, p = 0.007). CONCLUSION: Both TRUS and TAUS are comparable at TZ volume estimation and therefore TAUS can be utilized in regions where intracavitary probes and or the expertise is/are not available.

Abstract licence: CC BY

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.