Air Quality in a Dental Skills Lab during the SARS-CoV-2 Pandemic: Results of an Experimental Study

Christian Graetz, Naomi Sayk, Paulina Düffert and 3 more

International Journal of Dentistry · 2022

doi:10.1155/2022/9973623 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

Objectives. The study aimed to analyze different ways to control air quality during/after aerosol-generating procedures (AGPs) in a small skills lab with restricted natural air ventilation in preclinical dental training (worst-case scenario for aerogen infection control). Different phases were investigated (AGP1: intraoral high-volume evacuation (HVE); AGP2: HVE plus an extraoral mobile scavenger (EOS)) and afterward (non-AGP1: air conditioning system (AC), non-AGP2: AC plus opened door). Methods. Continuous data collection was performed for PM1, PM2.5, and PM10 (µg/m3), CO2 concentration (ppm), temperature (K), and humidity (h−1) during two summer days (AGP: n = 30; non-AGP: n = 30). While simulating our teaching routine, no base level for air parameters was defined. Therefore, the change in each parameter (Δ = [post]-[pre] per hour) was calculated. Results. We found significant differences in ΔPM2.5 and ΔPM1 values (median (25/75th percentiles)) comparing AGP2 versus AGP1 (ΔPM2.5: 1.6(0/4.9)/−3.5(−10.0/−1.1), p=0.003; ΔPM1: 1.6(0.6/2.2)/−2.2(−9.3/−0.5), p=0.001). Between both non-AGPs, there were no significant differences in all the parameters that were measured. ΔCO2 increased in all AGP phases (AGP1/AGP2: 979.0(625.7/1126.9)/549.9(4.0/788.8)), while during non-AGP phases, values decreased (non-AGP1/non-AGP2: −447.3(−1122.3/641.2)/−896.6(−1307.3/−510.8)). ∆Temperature findings were similar (AGP1/AGP2: 12.5(7.8/17.0)/9.3(1.8/15.3) versus non-AGP1/non-AGP2: −13.1(−18.7/0)/−14.7(−16.8/−6.8); p≤0.003)), while for ∆humidity, no significant difference (p>0.05) was found. Conclusions. Within the limitations of the study, the combination of HVE and EOS was similarly effective in controlling aerosol emissions of particles between one and ten micrometers in skill labs during AGPs versus that during non-AGPs. After AGPs, air exchange with the AC should be complemented by open doors for better air quality if natural ventilation through open windows is restricted.

Abstract licence: CC BY

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.