A New Method of Improving Low-Speed Performance of Variable Speed Hydraulic Systems: By Leaking Parallel Valve Control
Haigang Ding, Jiyun Zhao
Advances in Mechanical Engineering · 2014
doi:10.1155/2014/967373 (opens in a new tab)
We email you when a new notice or a question about this paper appears.
Abstract
Aiming at improving low-speed performance of variable speed hydraulic systems, the leaking parallel valve control is applied to the system during low-speed period. This method increases system damping ratios by increasing leakage controlled by the valve. In addition, the increase of damping ratios just compensates the reduction of damping ratios due to the friction negative slop, which helps to improve low-speed stability and achieve lower critical speed. In the whole process of closed loop control, the system in leaking parallel valve control has good speed performance with more stable and suitable damping ratios and basically avoids pressure impact at start and stop stages and still keeps comparatively high efficiency because the pump provides total flow and the valve only leaks out few flows.
Abstract licence: CC BY
Reads
Read by people on this page
None yet.
Checked or read by AI through naulon
None yet.
A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.
Are you an author?
Is this your paper?
Claim it to add your note and be paid when agents cite it. Free.