Not checkedNot checked for notices yet.
Rationalising oxygen usage in a level II special newborn care unit in Madhya Pradesh, India
Anu Thukral, Praveen Kumar, Jogender Kumar and 7 more
BMJ Open Quality · 2021
doi:10.1136/bmjoq-2021-001386 (opens in a new tab)
We email you when a new notice or a question about this paper appears.
Abstract
Non-judicious oxygen use in preterm infants is associated with increased risk of retinopathy of prematurity, bronchopulmonary dysplasia and longer hospital stay. Despite established guidelines on oxygen therapy, compliance with the best oxygen practices remains suboptimal. Excessive use of oxygen also consumes a large proportion of the annual maintenance budget of special newborn care units (SNCUs) in the districts. In this project, we aimed to reduce the oxygen consumption in the SNCU at Sehore, Madhya Pradesh, India from eight to four cylinders per day, by rationalising the indications, monitoring and method of oxygen delivery.We tested two sets of interventions using the Plan-Do-Study-Act (PDSA) approach. The first intervention was the introduction of a written 'oxygen policy' regarding indications of starting/stopping oxygen and the use of saturation targets. The second was using short binasal infant prongs (at 0.5-1 L/min), instead of oxygen hoods as the primary method of oxygen delivery in spontaneously breathing neonates requiring oxygen. In the first PDSA cycle, we assessed the feasibility of the intervention in a small set (n=30) of neonates and later scaled up to all eligible neonates in the second phase.We observed a significant reduction in oxygen consumption (from median (IQR) 8 (7-8) to 3 (3-4) cylinders per day) that can lead to a direct saving of 590 000 Indian rupees (US$9000) per year. There was a significant reduction in the number of neonates on oxygen support on a given day. We did not observe any increase in mortality or nasal injury. The change was sustained for the next 8 months.We conclude that by having a contextual oxygen policy and using nasal prongs instead of oxygen hoods as the preferred delivery method, we can achieve a sustainable reduction in oxygen consumption.
Abstract licence: CC BY-NC
References13
13 more references, whose wording the paper’s licence keeps private.
Reads
Read by people on this page
None yet.
Checked or read by AI through naulon
None yet.
A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.
Are you an author?
Is this your paper?
Claim it to add your note and be paid when agents cite it. Free.