Skip to content
naulon
Not checkedNot checked for notices yet.

Reduced tear thrombospondin‐1/matrix metalloproteinase‐9 ratio can aid in detecting Sjögren's syndrome etiology in patients with dry eye

Sharmila Masli, Esen K. Akpek

Clinical and Translational Science · 2022

doi:10.1111/cts.13316 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

Abstract Differentiating patients with Sjögren's syndrome (SS)‐associated dry eye from non‐SS dry eye is critical for monitoring and appropriate management of possible sight‐ or life‐threatening extraglandular complications associated with SS. We tested whether reduced tear levels of immunoregulatory thrombospondin (TSP)‐1, which also inhibits matrix metalloproteinase (MMP)‐9, would reflect SS pathogenesis aiding the identification of patients with SS‐dry eye. Total of 61 participants, including healthy controls (n = 20), patients with non‐SS dry eye (n = 20) and SS‐dry eye (n = 21) were enrolled prospectively. Tear TSP‐1 and MMP‐9 levels were measured using a custom magnetic bead‐based multi‐plex assay in a masked manner. Analyte concentrations were assessed further according to ocular surface and tear film parameters. Relative to median tear TSP‐1 (308 ng/ml) and MMP‐9 (1.9 ng/ml) levels in the control group, significantly higher proportion of patients with SS‐dry eye than non‐SS had lower tear TSP‐1 levels (55% vs. 29%, odds ratio [OR] = 3, 95% confidence interval [CI] = 1.64 to 5.35, p < 0.05) and higher tear MMP‐9 levels (65% vs. 24%, OR = 5.8, 95% CI = 4.46 to 19.81, p < 0.05), respectively. The tear TSP‐1/MMP‐9 ratio was significantly reduced in patients with SS‐dry eye compared to non‐SS (B = −2.36, 95% CI = −3.94 to −0.0.79, p < 0.05), regardless of tear MMP‐9 levels. Patients with a lower ratio were 2.3 times more likely to have SS (OR = 0.28, 95% CI = 0.1 to 0.75, p < 0.05). This ratio showed significant inverse correlations with clinical parameters (conjunctival and corneal staining scores). Our results denote that tear TSP‐1/MMP‐9 ratio can be useful in identifying patients with dry eye with underlying SS and used as a screening test.

Abstract licence: CC BY-NC

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.