Quantitative analysis of endobronchial ultrasound elastography in computed tomography‐negative mediastinal and hilar lymph nodes

Keigo Uchimura, Kei Yamasaki, Shinji Sasada and 6 more

Thoracic Cancer · 2020

doi:10.1111/1759-7714.13579 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

Background Endobronchial ultrasound (EBUS) elastography assists in the differentiation of benign and malignant lymph nodes (LNs) during transbronchial needle aspiration (TBNA). However, previous studies have not compared B‐mode sonographic images (BSIs) and EBUS elastography images (EEIs) with final pathological diagnoses in radiologically normal‐sized (computed tomography [CT]‐negative) LNs. Methods Consecutive patients with CT‐negative LNs, who received EBUS‐TBNA, were retrospectively reviewed. Images of BSIs and EEIs of each LN were stored and independently evaluated. EEIs were assessed by calculating the stiffness area ratio (SAR, blue/overall areas). The receiver operating characteristic curve was used to calculate the cutoff value for the SAR. Diagnostic test parameters were evaluated for each EBUS finding. Results A total of 132 patients (149 LNs) were enrolled, and the median SAR of malignant LNs was significantly higher than that of benign LNs (0.58 vs. 0.32, P < 0.001). At the SAR cutoff of 0.41, the sensitivity, specificity, positive predictive value, negative predictive value (NPV), and diagnostic accuracy rate (DAR) of elastography were 88.2%, 80.2%, 78.9%, 89.0%, and 83.9%, respectively. The logistic regression analysis showed that elastography was the strongest predictor of malignancy (odds ratio, 18.5; 95% confidence interval [CI]: 6.48–52.6; P < 0.001). The highest NPV (96.6%) was achieved with a combination of BSIs and EEIs. Conclusions EBUS elastography predicted malignant LNs with a high DAR and NPV in CT‐negative LNs. The NPV was highest when EEIs were combined with BSIs. Therefore, the combined evaluation of CT‐negative LNs using EEIs and BSIs may help bronchoscopists perform EBUS‐TBNA more efficiently. Key points Significant findings of the study Endobronchial ultrasound elastography accurately predicted malignancy with a high diagnostic accuracy rate and negative predictive value in radiologically normal‐sized lymph nodes. The additional use of B‐mode sonographic features resulted in a higher negative predictive value. What this study adds Endobronchial ultrasound elastography can guide the accurate collection of specimens with transbronchial needle aspiration, even in radiologically normal‐sized lymph nodes. It can also readily distinguish benign and malignant lymph nodes, thus avoiding unnecessary punctures.

Abstract licence: CC BY-NC

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.