Unobtrusive Sensing and Wearable Devices for Health Informatics
Ya-Li Zheng, Xiao-Rong Ding, Carmen Chung Yan Poon and 6 more
IEEE Transactions on Biomedical Engineering · 2014 · Review
Abstract
The aging population, prevalence of chronic diseases, and outbreaks of infectious diseases are some of the major challenges of our present-day society. To address these unmet healthcare needs, especially for the early prediction and treatment of major diseases, health informatics, which deals with the acquisition, transmission, processing, storage, retrieval, and use of health information, has emerged as an active area of interdisciplinary research. In particular, acquisition of health-related information by unobtrusive sensing and wearable technologies is considered as a cornerstone in health informatics. Sensors can be weaved or integrated into clothing, accessories, and the living environment, such that health information can be acquired seamlessly and pervasively in daily living. Sensors can even be designed as stick-on electronic tattoos or directly printed onto human skin to enable long-term health monitoring. This paper aims to provide an overview of four emerging unobtrusive and wearable technologies, which are essential to the realization of pervasive health information acquisition, including: (1) unobtrusive sensing methods, (2) smart textile technology, (3) flexible-stretchable-printable electronics, and (4) sensor fusion, and then to identify some future directions of research.
Shown for reading. Its publisher allows quoting it, not republishing it.
References 160
- 1.
Bloom D. E., Cafiero E. T., Jané-Llopis E., Abrahams-Gessel S., Bloom L. R., Fathima S., Feigl A. B., Gaziano T., Mowafi M., Pandya A., Prettner K., Rosenberg L., Seligman B., Stein A. Z., and Weinstein C., The Global Economic Burden of Non-Communicable Diseases, Geneva, Switzerland: World Economic Forum, Jul. 2011.
Not in our library
- 2.
Zhang Y. T. and Poon C. C. Y., “Editorial note on the processing, storage, transmission, acquisition, and retrieval (P-STAR) of bio, medical, and health information”, IEEE Trans. Inf. Technol. Biomed., vol. 14, no. 4, pp. 895–896, Jul. 2010.
Not in our library10.1109/titb.2010.2051834
- 3.
Poon C. C. Y., Wong Y. M., and Zhang Y.-T., “M-Health: The development of cuff-less and wearable blood pressure meters for use in body sensor networks”, in Proc. IEEE/NLM Life Sci. Syst. Appl. Workshop, Bethesda, MD, 2006, pp. 1–2.
Not in our library
- 4.
Kim D. H., Lu N., Ma R., Kim Y. S., Kim R. H., Wang S., Wu J., Won S. M., Tao H., Islam A., Yu K. J., Kim T.-i., Chowdhury R., Ying M., Xu L. Z., Li M., Chung H. J., Keum H., McCormick M., Liu P., Zhang Y. W., Omenetto F. G., Huang Y. G., Coleman T., and Rogers J. A., “Epidermal electronics”, Science, vol. 333, no. 6044, pp. 838–843, Aug. 2011.
Not in our library10.1126/science.1206157
- 5.
Zhang Y. T. and Poon C. C. Y., “Health informatics: Unobtrusive physiological measurement technologies”, IEEE J. Biomed. Health Informat., vol. 17, no. 5, p. 893, Sep. 2013.
Not in our library10.1109/jbhi.2013.2279187
- 6.
Wu K. F., Chan C. H., and Zhang Y. T., “Contactless and cuffless monitoring of blood pressure on a chair using e-textile materials”, in Proc. 3rd IEEE/EMBS Int. Summer School Med. Devices Biosensors, Cambridge, MA, 2006, pp. 98–100.
Not in our library
- 7.
Baek H., Chung G., Kim K., and Park K., “A smart health monitoring chair for nonintrusive measurement of biological signals”, IEEE Trans. Inf. Technol. Biomed., vol. 16, no. 1, pp. 150–158, Jan. 2012.
Not in our library10.1109/titb.2011.2175742
- 8.
Walter M., Eilebrecht B., Wartzek T., and Leonhardt S., “The smart car seat: Personalized monitoring of vital signs in automotive applications”, Pers. Ubiquitous Comput., vol. 15, no. 7, pp. 707–715, Oct. 2011.
Not in our library
- 9.
Gu W. B., Poon C. C. Y., Leung H. K., Sy M. Y., Wong M. Y. M., and Zhang Y. T., “A novel method for the contactless and continuous measurement of arterial blood pressure on a sleeping bed”, in Proc. Annu. Int. Conf. IEEE Eng. Med. Biol. Soc., 2009, pp. 6084–6086.
Not in our library10.1109/iembs.2009.5335393
- 10.
Poh M. Z., McDuff D., and Picard R., “A medical mirror for non-contact health monitoring”, in Proc. ACM SIGGRAPH 2011 Emerging Technol., Vancouver, BC Canada, 2011, pp. 1–1.
Not in our library
- 11.
Gomez-Clapers J. and Casanella R., “A fast and easy-to-use ECG acquisition and heart rate monitoring system using a wireless steering wheel”, IEEE Sens. J., vol. 12, no. 3, pp. 610–616, Mar. 2012.
Not in our library
- 12.
Lin Y., “A natural contact sensor paradigm for nonintrusive and real-time sensing of biosignals in human-machine interactions”, IEEE Sens. J., vol. 11, no. 3, pp. 522–529, Mar. 2011.
Not in our library
- 13.
Ko Keun K., Yong Kyu L., and Kwang-Suk P., “The electrically noncontacting ECG measurement on the toilet seat using the capacitively-coupled insulated electrodes”, in Proc. 26th Annu. Int. Conf. IEEE Eng. Med. Biol. Soc., San Francisco, CA USA, 2004, pp. 2375–2378.
Not in our library10.1109/iembs.2004.1403688
- 14.
Inan O. T., Park D., Giovangrandi L., and Kovacs G. T. A., “Noninvasive measurement of physiological signals on a modified home bathroom scale”, IEEE Trans. Biomed. Eng., vol. 59, no. 8, pp. 2137–2143, Aug. 2012.
Not in our library10.1109/tbme.2012.2186809
- 15.
Chi Y. M., Deiss S. R., and Cauwenberghs G., “Non-contact low power EEG/ECG electrode for high density wearable biopotential sensor networks”, in Proc. 6th Int. Workshop Wearable Implantable Body Sensor Netw., Berkeley, CA, 2009, pp. 246–250.
Not in our library
- 16.
Hoffmann T., Eilebrecht B., and Leonhardt S., “Respiratory monitoring system on the basis of capacitive textile force sensors”, IEEE Sens. J., vol. 11, no. 5, pp. 1112–1119, 2011.
Not in our library
- 17.
Wartzek T., Weyer S., and Leonhardt S., “A differential capacitive electrical field sensor array for contactless measurement of respiratory rate”, Physiol. Meas., vol. 32, no. 10, pp. 1575–1590, Oct. 2011.
Not in our library10.1088/0967-3334/32/10/006
- 18.
Chulsung P., Chou P. H., Ying B., Matthews R., and Hibbs A., “An ultra-wearable, wireless, low power ECG monitoring system”, in Proc. IEEE Biomed. Circuits Syst. Conf., London, U.K., 2006, pp. 241–244.
Not in our library
- 19.
Aleksandrowicz A. and Leonhardt S., “Wireless and non-contact ECG measurement system—The Aachen smartchair”, Acta Polytechnica, vol. 2, pp. 68–71, 2007.
Not in our library
- 20.
Yama Y., Ueno A., and Uchikawa Y., “Development of a wireless capacitive sensor for ambulatory ECG monitoring over clothes”, in Proc. 29th Annu. Int. Conf. IEEE Eng. Med. Biol. Soc., Lyon, France, 2007, pp. 5727–5730.
Not in our library10.1109/iembs.2007.4353647
- 21.
Fuhrhop S., Lamparth S., and Heuer S., “A textile integrated long-term ECG monitor with capacitively coupled electrodes”, in Proc. IEEE Biomed. Circuits Syst. Conf., Beijing, China, 2009, pp. 21–24.
Not in our library
- 22.
Chi Y. M. and Cauwenberghs G., “Wireless non-contact EEG/ECG electrodes for body sensor networks”, in Proc. Int. Conf. Body Sensor Netw., Singapore, 2010, pp. 297–301.
Not in our library
- 23.
Nemati E., Deen M. J., and Mondal T., “A wireless wearable ECG sensor for long-term applications”, IEEE Commun. Mag., vol. 50, no. 1, pp. 36–43, Jan. 2012.
Not in our library
- 24.
GuoChen P. and Bocko M. F., “Non-contact ECG sensing employing gradiometer electrodes”, IEEE Trans. Biomed. Eng., vol. 60, no. 1, pp. 179–183, Jan. 2013.
Not in our library10.1109/tbme.2012.2219531
- 25.
Jae B. H., Sung C. G., Keun K. K., Soo K. J., and Suk P. K., “Photoplethysmogram measurement without direct skin-to-sensor contact using an adaptive light source intensity control”, IEEE Trans. Inf. Technol. Biomed., vol. 13, no. 6, pp. 1085–1088, Nov. 2009.
Not in our library10.1109/titb.2009.2031108
- 26.
Poh M. Z., McDuff D. J., and Picard R. W., “Advancements in noncontact, multiparameter physiological measurements using a webcam”, IEEE Trans. Biomed. Eng., vol. 58, no. 1, pp. 7–11, Jan. 2011.
Not in our library10.1109/tbme.2010.2086456
- 27.
Asada H. H., Shaltis P., Reisner A., Sokwoo R., and Hutchinson R. C., “Mobile monitoring with wearable photoplethysmographic biosensors”, IEEE Eng. Med. Biol., vol. 22, no. 3, pp. 28–40, 2003.
Not in our library10.1109/memb.2003.1213624
- 28.
Celka P., Verjus C., Vetter R., Renevey P., and Neuman V., “Motion resistant earphone located infrared based heart rate measurement device”, in Proc. 2nd Int. Conf. Biomed. Eng., Innsbruck, Austria, 2004, pp. 582–585.
Not in our library
- 29.
Mendelson Y., Duckworth R. J., and Comtois G., “A wearable reflectance pulse oximeter for remote physiological monitoring”, in Proc. 28th Annu. Int. Conf. IEEE Eng. Med. Biol. Soc., New York, NY, 2006, pp. 912–915.
Not in our library10.1109/iembs.2006.260137
- 30.
Lei W., Lo B., and Yang G.-Z., “Multichannel reflective PPG earpiece sensor with passive motion cancellation”, IEEE Trans. Biomed. Circuits Syst., vol. 1, no. 4, pp. 235–241, Dec. 2007.
Not in our library10.1109/tbcas.2007.910900
- 31.
Vogel S., Hulsbusch M., Hennig T., Blazek V., and Leonhardt S., “In-ear vital signs monitoring using a novel microoptic reflective sensor”, IEEE Trans. Inf. Technol. Biomed., vol. 13, no. 6, pp. 882–889, Nov. 2009.
Not in our library10.1109/titb.2009.2033268
- 32.
Spigulis J., Erts R., Nikiforovs V., and Kviesis-Kipge E., “Wearable wireless photoplethysmography sensors”, in Proc. Photon. Eur., 2008, pp. 69912O1–69912O7.
Not in our library
- 33.
Patterson J. A. C., McIlwraith D. G., and Yang G.-Z., “A flexible, low noise reflective PPG sensor platform for ear-worn heart rate monitoring”, in Proc. 6th Int. Workshop Wearable Implantable Body Sensor Netw., Berkeley, CA, 2009, pp. 286–291.
Not in our library
- 34.
Shin K., Kim Y., Bae S., Park K., and Kim S. Lim C. and Goh J. H., Eds., A novel headset with a transmissive PPG sensor for heart rate measurement in Proc. 13th Intl. Conf. Biomed. Engineering, vol. 23, Berlin, Germany: Springer, 2009, pp. 519–522.
Not in our library
- 35.
Poh M.-Z., Kim K., Goessling A., Swenson N., and Picard R., “Cardiovascular monitoring using earphones and a mobile device”, IEEE Pervasive Comput., vol. 11, no. 4, pp. 18–26, Oct-Dec 2012.
Not in our library
- 36.
Poh M. Z., Swenson N. C., and Picard R. W., “Motion-tolerant magnetic earring sensor and wireless earpiece for wearable photoplethysmography”, IEEE Trans. Inf. Technol. Biomed., vol. 14, no. 3, pp. 786–794, 5 2010.
Not in our library10.1109/titb.2010.2042607
- 37.
Zheng Y. L., Leung B., Sy S., Zhang Y. T., and Poon C. C. Y., “A clip-free eyeglasses-based wearable monitoring device for measuring photoplethysmograhic signals”, in Proc. 34th Annu. Int. Conf. IEEE Eng. Med. Biol. Soc., San Diego, CA, 2012, pp. 5022–5025.
Not in our library10.1109/embc.2012.6347121
- 38.
Lin Y. H., Lin C. F., and You H. Z. Chang R.-S., Kim T.-H. and Peng S.-L., Eds., A driver's physiological monitoring system based on a wearable PPG sensor and a smartphone Security-Enriched Urban Computing and Smart Grid, vol. 223, Berlin, Germany: Springer, 2011, pp. 326–335.
Not in our library
- 39.
Lamonaca F., Kurylyak Y., Grimaldi D., and Spagnuolo V., “Reliable pulse rate evaluation by smartphone”, in Proc. IEEE Int. Symp. Med. Measurements Appl. Proc., Budapest, Hungary, 2012, pp. 1–4.
Not in our library
- 40.
Poon C. C., Zhang Y.-T., and Liu Y., “Modeling of pulse transit time under the effects of hydrostatic pressure for cuffless blood pressure measurements”, in Proc. 3rd IEEE/EMBS Int. Summer School Med. Devices Biosensors, 2006, pp. 65–68.
Not in our library
- 41.
Poon C. C. Y. and Zhang Y. T., “Cuff-less and noninvasive measurements of arterial blood pressure by pulse transit time”, in Proc. 27th Annu. Int. Conf. IEEE Eng. Med. Biol. Soc., Shanghai, China, 2005, pp. 5877–5880.
Not in our library10.1109/iembs.2005.1615827
- 42.
Payne R., Symeonides C., Webb D., and Maxwell S., “Pulse transit time measured from the ECG: An unreliable marker of beat-to-beat blood pressure”, J. Appl. Phys., vol. 100, no. 1, p. 136, 2006.
Not in our library10.1152/japplphysiol.00657.2005
- 43.
Lanata A., Scilingo E. P., Nardini E., Loriga G., Paradiso R., and De-Rossi D., “Comparative evaluation of susceptibility to motion artifact in different wearable systems for monitoring respiratory rate”, IEEE Trans. Inf. Technol. Biomed., vol. 14, no. 2, pp. 378–386, Mar. 2010.
Not in our library10.1109/titb.2009.2037614
- 44.
Paradiso R., Loriga G., and Taccini N., “A wearable health care system based on knitted integrated sensors”, IEEE Trans. Inf. Technol. Biomed., vol. 9, no. 3, pp. 337–344, Sep. 2005.
Not in our library10.1109/titb.2005.854512
- 45.
Rajala S. and Lekkala J., “Film-type sensor materials PVDF and EMFi in measurement of cardiorespiratory signals: A review”, IEEE Sens. J., vol. 12, no. 3, pp. 439–446, Mar. 2012.
Not in our library
- 46.
Karki S. and Lekkala J., “A new method to measure heart rate with EMFi and PVDF materials”, J. Med. Eng. Technol., vol. 33, no. 7, pp. 551–558, 2009.
Not in our library10.1080/03091900903067424
- 47.
Zhang Z. B., Shen Y. H., Wang W. D., Wang B. Q., and Zheng J. W., “Design and implementation of sensing shirt for ambulatory cardiopulmonary monitoring”, J. Med. Biol. Eng., vol. 31, no. 3, pp. 207–215, 2011.
Not in our library
- 48.
Lanata A., Scilingo E. P., and De Rossi D., “A multimodal transducer for cardiopulmonary activity monitoring in emergency”, IEEE Trans. Inf. Technol. Biomed., vol. 14, no. 3, pp. 817–825, 5 2010.
Not in our library10.1109/titb.2009.2024414
- 49.
Dziuda L., Skibniewski F. W., Krej M., and Lewandowski J., “Monitoring respiration and cardiac activity using fiber bragg grating-based sensor”, IEEE Trans. Biomed. Eng., vol. 59, no. 7, pp. 1934–1942, Jul. 2012.
Not in our library10.1109/tbme.2012.2194145
- 50.
D'Angelo L. T., Weber S., Honda Y., Thiel T., Narbonneau F., and Lüth T. C., “A system for respiratory motion detection using optical fibers embedded into textiles”, in Proc. 30th Ann. Int. Conf. IEEE Eng. Med. Biol. Soc., Vancouver, BC Canada, 2008, pp. 3694–3697.
Not in our library10.1109/iembs.2008.4650011
- 51.
Postolache O., Girao P. S., Madeira R. N., and Postolache G., “Microwave FMCW Doppler radar implementation for in-house pervasive health care system”, in Proc. IEEE Int. Workshop Med. Measurements Appl., Ottawa, ON Canada, 2010, pp. 47–52.
Not in our library
- 52.
Bonds Q., Gerig J., Weller T. M., and Herzig P., “Towards core body temperature measurement via close proximity radiometric sensing”, IEEE Sens. J., vol. 12, no. 3, pp. 519–526, Mar. 2012.
Not in our library
- 53.
Schepers H. M., Koopman H. F. J. M., and Veltink P. H., “Ambulatory assessment of ankle and foot dynamics”, IEEE Trans. Biomed. Eng., vol. 54, no. 5, pp. 895–902, 5 2007.
Not in our library10.1109/tbme.2006.889769
- 54.
Penders J., van de Molengraft J., Altini M., Yazicioglu F., and Van Hoof C., “A low-power wireless ECG necklace for reliable cardiac activity monitoring on-the-move”, in Proc. Int. Conf. IEEE Eng. Med. Biol. Soc., 2011, pp. 1–4.
Not in our library
- 55.
Gu W. B., Poon C. C. Y., Sy M. Y., Leung H. K., Liang Y. P., and Zhang Y. T., “A h-shirt-based body sensor network for cuffless calibration and estimation of arterial blood pressure”, in Proc. 6th Int. Workshop Wearable Implantable Body Sensor Netw., Berkeley, CA, 2009, pp. 151–155.
Not in our library
- 56.
Lo B., Yang G.-Z., and Pansiot J., “Bayesian analysis of sub-plantar ground reaction force with BSN”, in Proc. 6th Int. Workshop Wearable Implantable Body Sensor Netw., Berkeley, CA, 2009, pp. 133–137.
Not in our library
- 57.
Rothmaier M., Selm B., Spichtig S., Haensse D., and Wolf M., “Photonic textiles for pulse oximetry”, Opt. Exp., vol. 16, no. 17, pp. 12973–12986, Aug. 2008.
Not in our library10.1364/oe.16.012973
- 58.
Yamada T., Hayamizu Y., Yamamoto Y., Yomogida Y., Izadi-Najafabadi A., Futaba D. N., and Hata K., “A stretchable carbon nanotube strain sensor for human-motion detection”, Nat. Nanotechnol., vol. 6, no. 5, pp. 296–301, 5 2011.
Not in our library10.1038/nnano.2011.36
- 59.
Wu Y. C., Chang C. S., Sawaguchi Y., Yu W. C., Chen M. J., Lin J. Y., Liu S. M., Han C. C., and Liang W. Śmigórski K., Ed., A mobile-phone-based health management system Health Management—Different Approaches and Solutions,: Rijeka, Croatia: InTech, 2011.
Not in our library
- 60.
Atallah L., Lo B., King R., and Yang G.-Z., “Sensor positioning for activity recognition using wearable accelerometers”, IEEE Trans. Biomed. Circuits Syst., vol. 5, no. 4, pp. 320–329, Aug. 2011.
Not in our library10.1109/tbcas.2011.2160540
- 61.
Adamson P. B., Abraham W. T., Aaron M., Aranda J. M. Jr., Bourge R. C., Smith A., Stevenson L. W., Bauman J. G., and Yadav J. S., “CHAMPION trial rationale and design: The long-term safety and clinical efficacy of a wireless pulmonary artery pressure monitoring system”, J. Card. Fail., vol. 17, no. 1, pp. 3–10, 2011.
Not in our library10.1016/j.cardfail.2010.08.002
- 62.
Pandolfino J. E., Richter J. E., Ours T., Guardino J. M., Chapman J., and Kahrilas P. J., “Ambulatory esophageal pH monitoring using a wireless system”, Am. J. Gastroenterol., vol. 98, no. 4, pp. 740–749, 2003.
Not in our library10.1111/j.1572-0241.2003.07398.x
- 63.
Poon C. C. Y. and Zhang Y. T., “Perspectives on high technologies for low-cost healthcare”, IEEE Eng. Med. Biol., vol. 27, no. 5, pp. 42–47, Oct. 2008.
Not in our library10.1109/memb.2008.923955
- 64.
Brigante C. M. N., Abbate N., Basile A., Faulisi A. C., and Sessa S., “Towards miniaturization of a MEMS-based wearable motion capture system”, IEEE Trans. Ind. Electron., vol. 58, no. 8, pp. 3234–3241, Aug. 2011.
Not in our library
- 65.
Chuo Y., Marzencki M., Hung B., Jaggernauth C., Tavakolian K., Lin P., and Kaminska B., “Mechanically flexible wireless multisensor platform for human physical activity and vitals monitoring”, IEEE Trans. Biomed. Circuits Syst., vol. 4, no. 5, pp. 281–294, Oct. 2010.
Not in our library10.1109/tbcas.2010.2052616
- 66.
Mandal S., Turicchia L., and Sarpeshkar R., “A low-power, battery-free tag for body sensor networks”, IEEE Pervasive Comput., vol. 9, no. 1, pp. 71–77, Mar. 2010.
Not in our library
- 67.
Merritt C. R., Nagle H. T., and Grant E., “Fabric-based active electrode design and fabrication for health monitoring clothing”, IEEE Trans. Inf. Technol. Biomed., vol. 13, no. 2, pp. 274–280, Mar. 2009.
Not in our library10.1109/titb.2009.2012408
- 68.
Istepanian R. S. H., Jovanov E., and Zhang Y. T., “Guest editorial introduction to the special section on m-Health: Beyond seamless mobility and global wireless health-care connectivity”, IEEE Trans. Inf. Technol. Biomed., vol. 8, no. 4, pp. 405–414, Dec. 2004.
Not in our library10.1109/titb.2004.840019
- 69.
Yang G. Z., Body Sensor Networks, London, U.K.: Springer, 2006.
Not in our library
- 70.
Golmie N., Cypher D., and Rébala O., “Performance analysis of low rate wireless technologies for medical applications”, Comput. Commun., vol. 28, no. 10, pp. 1266–1275, 2005.
Not in our library
- 71.
Kang K., Ryu J., Hur J., and Sha L., “Design and QoS of a wireless system for real-time remote electrocardiography”, IEEE J. Biomed. Health Informat., vol. 17, no. 3, pp. 745–755, 5 2013.
Not in our library10.1109/jbhi.2013.2237782
- 72.
Cavero E., Alesanco A., and Garcia J., “Enhanced protocol for real-time transmission of echocardiograms over wireless channels”, IEEE Trans. Biomed. Eng., vol. 59, no. 11, pp. 3212–3220, Nov. 2012.
Not in our library10.1109/tbme.2012.2207720
- 73.
Istepanian R. S. H., Philip N. Y., and Martini M. G., “Medical QoS provision based on reinforcement learning in ultrasound streaming over 3.5G wireless systems”, IEEE J. Sel. Areas Commun., vol. 27, no. 4, pp. 566–574, 5 2009.
Not in our library
- 74.
Ren Y., Pazzi R. W. N., and Boukerche A., “Monitoring patients via a secure and mobile healthcare system”, IEEE Wirel. Commun., vol. 17, no. 1, pp. 59–65, Feb. 2010.
Not in our library
- 75.
Malhotra K., Gardner S., and Patz R., “Implementation of elliptic-curve cryptography on mobile healthcare devices”, in Proc. IEEE Int. Conf. Netw., Sens. Control, London, U.K., 2007, pp. 239–244.
Not in our library
- 76.
Tan C. C., Wang H., Zhong S., and Li Q., “Body sensor network security: an identity-based cryptography approach”, in 1st ACM Conf. Wireless Netw. Securitypresented at the, Alexandria, VA USA, 2008.
Not in our library
- 77.
Poon C. C., Zhang Y. T., and Bao S. D., “A novel biometrics method to secure wireless body area sensor networks for telemedicine and m-health”, IEEE Commun. Mag., vol. 44, no. 4, pp. 73–81, Apr. 2006.
Not in our library
- 78.
Venkatasubramanian K. K., Banerjee A., and Gupta S. K. S., “PSKA: Usable and secure key agreement scheme for body area networks”, IEEE Trans. Inf. Technol. Biomed., vol. 14, no. 1, pp. 60–68, Jan. 2010.
Not in our library10.1109/titb.2009.2037617
- 79.
Venkatasubramanian K. K., Banerjee A., and Gupta S. K. S., “Plethysmogram-based secure inter-sensor communication in body area networks”, in Proc. IEEE Mil. Commun. Conf., San Diego, CA, 2008, pp. 1–7.
Not in our library
- 80.
Sahoo P. K., “Efficient security mechanisms for mHealth applications using wireless body sensor networks”, Sensors, vol. 12, no. 9, pp. 12606–12633, 2012.
Not in our library10.3390/s120912606
- 81.
Le X. H., Sankar R., Khalid M., and Lee S., “Public key cryptography-based security scheme for wireless sensor networks in healthcare”, in Proc. 4th Int. Conf. Uniquitous Informat. Manage. Commun., 2010, p. 5.
Not in our library
- 82.
Liu B., Wang X. F., Liu B. Y., Wang Q. F., Tan D. S., Song W. F., Hou X. J., Chen D., and Shen G. Z., “Advanced rechargeable lithium-ion batteries based on bendable ZnCo2O4-urchins-on-carbon-fibers electrodes”, Nano Res., vol. 6, no. 7, pp. 525–534, Jul. 2013.
Not in our library
- 83.
Fu Y., Cai X., Wu H., Lv Z., Hou S., Peng M., Yu X., and Zou D., “Fiber supercapacitors utilizing pen ink for flexible/wearable energy storage”, Adv. Mater., vol. 24, no. 42, pp. 5713–5718, 2012.
Not in our library10.1002/adma.201202930
- 84.
Xu H., Li J., Leung B. H. K., Poon C. C. Y., Ong B. S., Zhang Y., and Zhao N., “A high-sensitivity near-infrared phototransistor based on organic bulk heterojunction”, Nanoscale, vol. 5, no. 23, pp. 11850–11855, 2013.
Not in our library10.1039/c3nr03989g
- 85.
Abidi A. A., Pottie G. J., and Kaiser W. J., “Power-conscious design of wireless circuits and systems”, Proc. IEEE, vol. 88, no. 10, pp. 1528–1545, Oct. 2000.
Not in our library
- 86.
Shenck N. S. and Paradiso J. A., “Energy scavenging with shoe-mounted piezoelectrics”, IEEE Micro., vol. 21, no. 3, pp. 30–42, May-Jun 2001.
Not in our library
- 87.
Leonov V., “Thermoelectric energy harvesting of human body heat for wearable sensors”, IEEE Sens. J., vol. 13, no. 6, pp. 2284–2291, Jun. 2013.
Not in our library
- 88.
Kim S., Ho J. S., and Poon A. S. Y., “Midfield wireless powering of subwavelength autonomous devices”, PhRvL, vol. 110, no. 20, p. 203905, 2013.
Not in our library10.1103/physrevlett.110.203905
- 89.
Pizzuti G. P., Cifaldi S., and Nolfe G., “Digital sampling rate and ECG analysis”, J. Biomed. Eng., vol. 7, no. 3, pp. 247–250, 1985.
Not in our library10.1016/0141-5425(85)90027-5
- 90.
Feichtinger H., Príncipe J., Romero J., Singh Alvarado A., and Velasco G., “Approximate reconstruction of bandlimited functions for the integrate and fire sampler”, Adv. Comput. Math., vol. 36, no. 1, pp. 67–78, 2012.
Not in our library
- 91.
Alvarado A. S., Lakshminarayan C., and Principe J. C., “Time-based compression and classification of heartbeats”, IEEE Trans. Biomed. Eng., vol. 59, no. 6, pp. 1641–1648, Jun. 2012.
Not in our library10.1109/tbme.2012.2191407
- 92.
Loh P. K. K. and Allan L., “Medical informatics system with wireless sensor network-enabled for hospitals”, in Proc. Int. Conf. Intell. Sensors, Sensor Netw. Inf. Process. Conf., 2005, pp. 265–270.
Not in our library
- 93.
Health Informatics Personal Health Device Communication, IEEE Standard P11073, 2007.
Not in our library
- 94.
Yao J. and Warren S., “Applying the ISO/IEEE 11073 standards to wearable home health monitoring systems”, J. Clin. Monitor. Comp., vol. 19, no. 6, pp. 427–436, Dec. 2005.
Not in our library10.1007/s10877-005-2033-7
- 95.
Damas M., Pomares H., Gonzalez S., Olivares A., and Rojas I., “Ambient assisted living devices interoperability based on OSGi and the X73 standard”, Telemed. E-Health, vol. 19, no. 1, pp. 54–60, 2013.
Not in our library10.1089/tmj.2012.0052
- 96.
Mart´ınez-Espronceda M., Mart´ınez I., Serrano L., Led S., Trigo J. U. D., Marzo A., Escayola J., and Garc´ıa J. E., “Implementation methodology for interoperable personal health devices with low-voltage low-power constraints”, IEEE Trans. Inf. Technol. Biomed., vol. 15, no. 3, pp. 398–408, 2011.
Not in our library10.1109/titb.2011.2134861
- 97.
Yan I. R., Poon C. C. Y., and Zhang Y. T., “Evaluation scale to assess the accuracy of cuff-less blood pressure measuring devices”, Blood Press Monit., vol. 14, no. 6, p. 257, 2009.
Not in our library10.1097/mbp.0b013e328330aea8
- 98.
Buttussi F. and Chittaro L., “MOPET: A context-aware and user-adaptive wearable system for fitness training”, Artif. Intell. Med., vol. 42, no. 2, pp. 153–163, Feb. 2008.
Not in our library10.1016/j.artmed.2007.11.004
- 99.
Koay S. L., Kwon T. H., and Chung W. Y., “Motion artifacts cancellation by adaptive neuro-fuzzy inference system for wearable health shirts”, Sens. Lett., vol. 9, no. 1, pp. 399–403, Feb. 2011.
Not in our library
- 100.
Ko B. H., Lee T., Choi C., Kim Y. H., Park G., Kang K., Bae S. K., and Shin K., “Motion artifact reduction in electrocardiogram using adaptive filtering based on half cell potential monitoring”, in Proc. 2012 Annu. Int. Conf. IEEE Eng. Med. Biol. Soc., 2012, pp. 1590–1593.
Not in our library10.1109/embc.2012.6346248
- 101.
Yan Y. S. and Zhang Y. T., “An efficient motion-resistant method for wearable pulse oximeter”, IEEE Trans. Inf. Technol. Biomed., vol. 12, no. 3, pp. 399–405, 5 2008.
Not in our library10.1109/titb.2007.902173
- 102.
Coyle S., Lau K. T., Moyna N., O'Gorman D., Diamond D., Di Francesco F., Costanzo D., Salvo P., Trivella M. G., De Rossi D. E., Taccini N., Paradiso R., Porchet J. A., Ridolfi A., Luprano J., Chuzel C., Lanier T., Revol-Cavalier F., Schoumacker S., Mourier V., Chartier I., Convert R., De-Moncuit H., and Bini C., “BIOTEX-biosensing textiles for personalised healthcare management”, IEEE Trans. Inf. Technol. Biomed., vol. 14, no. 2, pp. 364–370, 5 2010.
Not in our library10.1109/titb.2009.2038484
- 103.
Poh M. Z., Loddenkemper T., Reinsberger C., Swenson N. C., Goyal S., Madsen J. R., and Picard R. W., “Autonomic changes with seizures correlate with postictal EEG suppression”, Neurology, vol. 78, no. 23, pp. 1868–1876, Jun. 2012.
Not in our library10.1212/wnl.0b013e318258f7f1
- 104.
Poh M.-Z., Swenson N. C., and Picard R. W., “A wearable sensor for unobtrusive, long-term assessment of electrodermal activity”, IEEE Trans. Biomed. Eng., vol. 57, no. 5, pp. 1243–1252, 5 2010.
Not in our library10.1109/tbme.2009.2038487
- 105.
Firoozbakhsh B., Jayant N., Park S., and Jayaraman S., “Wireless communication of vital signs using the georgia tech wearable motherboard”, in Proc. IEEE Int. Conf. Multimedia Expo, New York, 2000, pp. 1253–1256.
Not in our library
- 106.
Linz T., Kallmayer C., Aschenbrenner R., and Reichl H., “Fully untegrated EKG shirt based on embroidered electrical interconnections with conductive yarn and miniaturized flexible electronics”, in presented at Int. Workshop Wearable Implantable Body Sensor Netw., Cambridge, MA, 2006.
Not in our library
- 107.
Grossman P. Lymberis A. and Rossi D. E. D., Eds., The lifeshirt: A multi-function ambulatory system monitoring health, disease, and medical intervention in the real world Wearable Ehealth Systems for Personalised Health Management: State of the Art and Future Challenges, Headington, U.K.: IOS Press, 2004, pp. 133–141.
Not in our library
- 108.
Curone D., Secco E. L., Tognetti A., Loriga G., Dudnik G., Risatti M., Whyte R., Bonfiglio A., and Magenes G., “Smart garments for emergency operators: The proetex project”, IEEE Trans. Inf. Technol. Biomed., vol. 14, no. 3, pp. 694–701, 5 2010.
Not in our library10.1109/titb.2010.2045003
- 109.
Noury N., Dittmar A., Corroy C., Baghai R., Weber J. L., Blanc D., Klefstat F., Blinovska A., Vaysse S., and Comet B., “VTAMN - A smart clothe for ambulatory remote monitoring of physiological parameters and activity”, in Proc. 26th Annu. Int. Conf. IEEE Eng. Med. Biol. Soc., San Francisco, CA, 2004, pp. 3266–3269.
Not in our library10.1109/iembs.2004.1403919
- 110.
Yeo W.-H., Kim Y.-S., Lee J., Ameen A., Shi L., Li M., Wang S., Ma R., Jin S. H., Kang Z., Huang Y., and Rogers J. A., “Multifunctional epidermal electronics printed directly onto the skin”, Adv. Mater., vol. 25, no. 20, pp. 2773–2778, 2013.
Not in our library10.1002/adma.201204426
- 111.
Mannsfeld S. C., Tee B. C., Stoltenberg R. M., Chen C. V. H., Barman S., Muir B. V., Sokolov A. N., Reese C., and Bao Z., “Highly sensitive flexible pressure sensors with microstructured rubber dielectric layers”, Nat. Mater., vol. 9, no. 10, pp. 859–864, 2010.
Not in our library10.1038/nmat2834
- 112.
Schwartz G., Tee B. C.-K., Mei J., Appleton A. L., Wang H., and Bao Z., “Flexible polymer transistors with high pressure sensitivity for application in electronic skin and health monitoring”, Nat. Commun., vol. 4, p. 1859, 2013.
Not in our library10.1038/ncomms2832
- 113.
Someya T., “Building bionic skin”, IEEE Spectrum, vol. 50, no. 9, pp. 50–56, Sep. 2013.
Not in our library
- 114.
Chang H. X., Sun Z. H., Saito M., Yuan Q. H., Zhang H., Li J. H., Wang Z. C., Fujita T., Ding F., Zheng Z. J., Yan F., Wu H. K., Chen M. W., and Ikuhara Y., “Regulating infrared photoresponses in reduced graphene oxide phototransistors by defect and atomic structure control”, Acs Nano, vol. 7, no. 7, pp. 6310–6320, Jul. 2013.
Not in our library10.1021/nn4023679
- 115.
McAlpine M. C., Ahmad H., Wang D. W., and Heath J. R., “Highly ordered nanowire arrays on plastic substrates for ultrasensitive flexible chemical sensors”, Nat. Mater., vol. 6, no. 5, pp. 379–384, 5 2007.
Not in our library10.1038/nmat1891
- 116.
Jia W., Bandodkar A. J., Valdés-Ramírez G., Windmiller J. R., Yang Z., Ramírez J., Chan G., and Wang J., “Electrochemical tattoo biosensors for real-time noninvasive lactate monitoring in human perspiration”, Anal. Chem., vol. 85, no. 14, pp. 6553–6560, Jul. 2013.
Not in our library10.1021/ac401573r
- 117.
Manunza I. and Bonfiglio A., “Pressure sensing using a completely flexible organic transistor”, Biosens. Bioelectron., vol. 22, no. 12, pp. 2775–2779, Jun. 2007.
Not in our library10.1016/j.bios.2007.01.021
- 118.
Yi H. T., Payne M. M., Anthony J. E., and Podzorov V., “Ultra-flexible solution-processed organic field-effect transistors”, Nat. Commun., vol. 3, pp. 1259–1266, Dec. 2012.
Not in our library10.1038/ncomms2263
- 119.
Wang X., Song W., Liu B., Chen G., Chen D., Zhou C., and Shen G., “High-performance organic-inorganic hybrid photodetectors based on P3HT: CdSe nanowire heterojunctions on rigid and flexible substrates”, Adv. Funct. Mater., vol. 23, no. 9, pp. 1202–1209, 2013.
Not in our library
- 120.
Han T.-H., Lee Y., Choi M.-R., Woo S.-H., Bae S.-H., Hong B. H., Ahn J.-H., and Lee T.-W., “Extremely efficient flexible organic light-emitting diodes with modified graphene anode”, Nat. Photon., vol. 6, no. 2, pp. 105–110, 2012.
Not in our library
- 121.
Pang C., Lee G. Y., Kim T. i., Kim S. M., Kim H. N., Ahn S. H., and Suh K. Y., “A flexible and highly sensitive strain-gauge sensor using reversible interlocking of nanofibres”, Nat. Mater., vol. 11, pp. 795–801, 2012.
Not in our library10.1038/nmat3380
- 122.
Lakafosis V., Rida A., Vyas R., Li Y., Nikolaou S., and Tentzeris M. M., “Progress towards the first wireless sensor networks consisting of inkjet-printed, paper-based RFID-enabled sensor tags”, Proc. IEEE, vol. 98, no. 9, pp. 1601–1609, Sep. 2010.
Not in our library
- 123.
Xu S., Zhang Y. H., Cho J., Lee J., Huang X., Jia L., Fan J. A., Su Y. W., Su J., Zhang H. G., Cheng H. Y., Lu B. W., Yu C. J., Chuang C., Kim T. I., Song T., Shigeta K., Kang S., Dagdeviren C., Petrov I., Braun P. V., Huang Y. G., Paik U., and Rogers J. A., “Stretchable batteries with self-similar serpentine interconnects and integrated wireless recharging systems”, Nat. Commun., vol. 4, pp. 1543–1551, Feb. 2013.
Not in our library10.1038/ncomms2553
- 124.
Gwon H., Kim H. S., Lee K. U., Seo D. H., Park Y. C., Lee Y. S., Ahn B. T., and Kang K., “Flexible energy storage devices based on graphene paper”, Energy Environ. Sci., vol. 4, no. 4, pp. 1277–1283, Apr. 2011.
Not in our library
- 125.
Chen P. C., Chen H. T., Qiu J., and Zhou C. W., “Inkjet printing of single-walled carbon nanotube/ruO2 nanowire supercapacitors on cloth fabrics and flexible substrates”, Nano. Res., vol. 3, no. 8, pp. 594–603, Aug. 2010.
Not in our library
- 126.
Kim D.-H., Ghaffari R., Lu N., and Rogers J. A., “Flexible and stretchable electronics for biointegrated devices”, Annu. Rev. Biomed. Eng., vol. 14, no. 1, pp. 113–128, 2012.
Not in our library10.1146/annurev-bioeng-071811-150018
- 127.
Khang D. Y., Jiang H. Q., Huang Y., and Rogers J. A., “A stretchable form of single-crystal silicon for high-performance electronics on rubber substrates”, Science, vol. 311, no. 5758, pp. 208–212, Jan. 2006.
Not in our library10.1126/science.1121401
- 128.
Wang Y., Yang R., Shi Z. W., Zhang L. C., Shi D. X., Wang E., and Zhang G. Y., “Super-elastic graphene ripples for flexible strain sensors”, ACS Nano, vol. 5, no. 5, pp. 3645–3650, 5 2011.
Not in our library10.1021/nn103523t
- 129.
Song J., Huang Y., Xiao J., Wang S., Hwang K. C., Ko H. C., Kim D. H., Stoykovich M. P., and Rogers J. A., “Mechanics of noncoplanar mesh design for stretchable electronic circuits”, J. Appl. Phys., vol. 105, no. 12, pp. 123516-1–123516-6, Jun. 2009.
Not in our library
- 130.
White M. S., Kaltenbrunner M., Glowacki E. D., Gutnichenko K., Kettlgruber G., Graz I., Aazou S., Ulbricht C., Egbe D. A. M., Miron M. C., Major Z., Scharber M. C., Sekitani T., Someya T., Bauer S., and Sariciftci N. S., “Ultrathin, highly flexible and stretchable PLEDs”, Nat. Photon., vol. 7, no. 10, pp. 811–816, Oct. 2013.
Not in our library
- 131.
Meng Y. N., Zhao Y., Hu C. G., Cheng H. H., Hu Y., Zhang Z. P., Shi G. Q., and Qu L. T., “All-graphene core-sheath microfibers for all-solid-state, stretchable fibriform supercapacitors and wearable electronic textiles”, Adv. Mater., vol. 25, no. 16, pp. 2326–2331, Apr. 2013.
Not in our library10.1002/adma.201300132
- 132.
Sekitani T., Noguchi Y., Hata K., Fukushima T., Aida T., and Someya T., “A rubberlike stretchable active matrix using elastic conductors”, Science, vol. 321, no. 5895, pp. 1468–1472, Sep. 2008.
Not in our library10.1126/science.1160309
- 133.
Kim Y., Zhu J., Yeom B., Di Prima M., Su X. L., Kim J. G., Yoo S. J., Uher C., and Kotov N. A., “Stretchable nanoparticle conductors with self-organized conductive pathways”, Nature, vol. 500, no. 7460, pp. U59–U77, Aug. 2013.
Not in our library10.1038/nature12401
- 134.
Seol Y. G., Trung T. Q., Yoon O. J., Sohn I. Y., and Lee N. E., “Nanocomposites of reduced graphene oxide nanosheets and conducting polymer for stretchable transparent conducting electrodes”, J. Mater. Chem., vol. 22, no. 45, pp. 23759–23766, Dec. 2012.
Not in our library
- 135.
Khaleghi B., Khamis A., Karray F. O., and Razavi S. N., “Multisensor data fusion: A review of the state-of-the-art”, Inf. Fusion, vol. 14, no. 1, pp. 28–44, 2013.
Not in our library
- 136.
F. E. White, Data Fusion Lexicon. San Diego, CA, USA: Joint Directors of Laboratories, Technical Panel for C3, Data Fusion Sub-Panel, Naval Ocean Systems Center, 1991.
Not in our library
- 137.
H. Boström, S. F. Andler, M. Brohede, R. Johansson, A. Karlsson, J. van Laere, L. Niklasson, M. Nilsson, A. Persson, and T. Ziemke, On the definition of information fusion as a field of research. in Technical Report, Skovde, Sweden: University of Skövde, School of Humanities and Informatics, 2007.
Not in our library
- 138.
Huang Y., McCullagh P., Black N., and Harper R., “Feature selection and classification model construction on type 2 diabetic patients' data”, Artif. Intell. Med., vol. 41, no. 3, pp. 251–262, Nov. 2007.
Not in our library10.1016/j.artmed.2007.07.002
- 139.
O’Connor M. J., Shankar R. D., Parrish D. B., and Das A. K., “Knowledge-data integration for temporal reasoning in a clinical trial system”, Int. J. Med. Inform., vol. 78, no. 1, pp. S77–S85, 2009.
Not in our library10.1016/j.ijmedinf.2008.07.013
- 140.
Wang X., Chase H., Markatou M., Hripcsak G., and Friedman C., “Selecting information in electronic health records for knowledge acquisition”, J. Biomed. Inform., vol. 43, no. 4, pp. 595–601, 2010.
Not in our library10.1016/j.jbi.2010.03.011
- 141.
Noren G. N., Hopstadius J., Bate A., Star K., and Edwards I. R., “Temporal pattern discovery in longitudinal electronic patient records”, Data Min. Knowl. Discov., vol. 20, no. 3, pp. 361–387, 5 2010.
Not in our library
- 142.
Han J. and Kember J., Data Mining Concepts and Techniques, San Mateo, CA: Morgan Kaufmann, 2000.
Not in our library
- 143.
Hashem S., “Optimal linear combinations of neural networks”, Neural Netw., vol. 10, no. 4, pp. 599–614, Jun. 1997.
Not in our library10.1016/s0893-6080(96)00098-6
- 144.
Huang D. and Leung H., “An expectation-maximization-based interacting multiple model approach for cooperative driving systems”, IEEE Trans. Intell. Transp., vol. 6, no. 2, pp. 206–228, Jun. 2005.
Not in our library
- 145.
Dubois D. and Prade H., Possibility Theory, New York, NY: Plenum Press, 1988.
Not in our library
- 146.
Jensen P. B., Jensen L. J., and Brunak S., “Mining electronic health records: Towards better research applications and clinical care”, Nat. Rev. Genet., vol. 13, no. 6, pp. 395–405, Jun. 2012.
Not in our library10.1038/nrg3208
- 147.
Kurt I., Ture M., and Kurum A. T., “Comparing performances of logistic regression, classification and regression tree, and neural networks for predicting coronary artery disease”, Expert. Syst. Appl., vol. 34, no. 1, pp. 366–374, 2008.
Not in our library
- 148.
Taber R., “Knowledge processing with fuzzy cognitive maps”, Expert. Syst. Appl., vol. 2, no. 1, pp. 83–87, 1991.
Not in our library
- 149.
Papageorgiou E. I., “A new methodology for decisions in medical informatics using fuzzy cognitive maps based on fuzzy rule-extraction techniques”, Appl. Soft. Comput., vol. 11, no. 1, pp. 500–513, 2011.
Not in our library
- 150.
Euheart. (2008 ). Euheart—Matters of the heart [Online], [Online]. Available: http://www.euheart.eu/index.php?id=euheart-home accessed in Dec. 2013.
Not in our library
- 151.
Gao H., Poon C. C. Y., Yang P., and Zhang Y. T., “Risk prediction of cardiovascular disease”, in 7th Int. School Symp. Med. Devices Biosensors Conjunction 6th Int. School Symp. Biomed. Health Eng.presented at the, Hongkong and Shenzhen, China, 2010.
Not in our library
- 152.
Y. Dong, Y. Yun, L. Xiao, L. Wenhao, C. Lizhen, X. Meng, and C. Jinjun, “A highly practical approach toward achieving minimum data sets storage cost in the cloud,” IEEE Trans. Parallel Distrib. Syst., vol. 24, no. 6, pp. 1234–1244, Jun. 2013.
Not in our library
- 153.
Mu X. and Lu K., “Towards effective genomic information retrieval: The impact of query complexity and expansion strategies”, J. Inf. Sci., vol. 36, no. 2, pp. 194–208, 2010.
Not in our library
- 154.
Natarajan K., Stein D., Jain S., and Elhadad N., “An analysis of clinical queries in an electronic health record search utility”, Int. J. Med. Inform., vol. 79, no. 7, pp. 515–522, 2010.
Not in our library10.1016/j.ijmedinf.2010.03.004
- 155.
Sujansky and Associates, LLC, “A standards-based model for the sharing of patient-generated health information with electronic health records,” in Technical Report, 2013, [Online]. Available: http://www.projecthealthdesign.org/ accessed in Jan. 2014.
Not in our library
- 156.
Coles-Kemp L., Reddington J., and Williams P. A. H., “Looking at clouds from both sides: The advantages and disadvantages of placing personal narratives in the cloud”, Inf. Security Tech. Rep., vol. 16, no. 3–4, pp. 115–122, 2011.
Not in our library
- 157.
Rolim C. O., Koch F. L., Westphall C. B., Werner J., Fracalossi A., and Salvador G. S., A Cloud Computing Solution for Patient's Data Collection in Health Care Institutions, Los Alamitos, CA: IEEE Computer Society, 2010.
Not in our library
- 158.
Poulymenopoulou M., Malamateniou F., and Vassilacopoulos G., “Emergency healthcare process automation using mobile computing and cloud services”, J. Med. Syst., vol. 36, no. 5, pp. 3233–3241, Oct. 2012.
Not in our library10.1007/s10916-011-9814-y
- 159.
AbuKhousa E., Mohamed N., and Al-Jaroodi J., “e-Health cloud: Opportunities and challenges”, Future Internet, vol. 4, no. 3, pp. 621–645, 2012.
Not in our library
- 160.
Dixon B. E., Simonaitis L., Goldberg H. S., Paterno M. D., Schaeffer M., Hongsermeier T., Wright A., and Middleton B., “A pilot study of distributed knowledge management and clinical decision support in the cloud”, Artif. Intell. Med., vol. 59, no. 1, pp. 45–53, Sep. 2013.
Not in our library10.1016/j.artmed.2013.03.004
Cited by papers we hold 4
- Gold and silver nanocomposite-based biostable and biocompatible electronic textile for wearable electromyographic biosensors · 2021Not checked
- E-Textiles for Healthy Ageing · 2019Not checked
- A Transparent Strain Sensor Based on PDMS-Embedded Conductive Fabric for Wearable Sensing Applications · 2018Not checked
- Making sense of big data in health research: Towards an EU action plan · 2016Corrected
Reads
Read by people on this page
None yet.
Checked or read by AI through naulon
None yet.
A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.
Are you an author?
Is this your paper?
Claim it to add your note and be paid when agents cite it. Free.