Breathing Rate Estimation From the Electrocardiogram and Photoplethysmogram: A Review
Peter H. Charlton, Drew A. Birrenkott, Timothy Bonnici and 7 more
IEEE Reviews in Biomedical Engineering · 2018 · Review · CC BY
Abstract
Breathing rate (BR) is a key physiological parameter used in a range of clinical settings. Despite its diagnostic and prognostic value, it is still widely measured by counting breaths manually. A plethora of algorithms have been proposed to estimate BR from the electrocardiogram (ECG) and pulse oximetry (photoplethysmogram, PPG) signals. These BR algorithms provide opportunity for automated, electronic, and unobtrusive measurement of BR in both healthcare and fitness monitoring. This paper presents a review of the literature on BR estimation from the ECG and PPG. First, the structure of BR algorithms and the mathematical techniques used at each stage are described. Second, the experimental methodologies that have been used to assess the performance of BR algorithms are reviewed, and a methodological framework for the assessment of BR algorithms is presented. Third, we outline the most pressing directions for future research, including the steps required to use BR algorithms in wearable sensors, remote video monitoring, and clinical practice.
References 262
- 1.
Charlton PH. Ph D dissertation. 2017.
Not in our library
- 2.
Cretikos M, et al. The objective medical emergency team activation criteria: A case-control study. Resuscitation. 2007;73(1):62-72.
Not in our library10.1016/j.resuscitation.2006.08.020
- 3.
Schein RM, et al. Clinical antecedents to in-hospital cardiopulmonary arrest. Chest. 1990;98(6):1388-1392.
Not in our library10.1378/chest.98.6.1388
- 4.
Duckitt RW, et al. Worthing physiological scoring system: derivation and validation of a physiological early-warning system for medical admissions. An observational, population-based single-centre study. Brit J Anaesthesia. 2007;98(6):769-774.
Not in our library10.1093/bja/aem097
- 5.
Gravelyn TR, Weg JG. Respiratory rate as an indicator of acute respiratory dysfunction. J Amer Med Assoc. 1980;244(10):1123-1125.
Not in our library10.1001/jama.1980.03310100041029
- 6.
National Early Warning Score (NEWS): Standardising the assessment of acute-illness severity in the NHS. Report of a working party. 2012.
Not in our library
- 7.
- 8.
Karlen W, Raman S, Ansermino JM, Dumont GA. Multiparameter respiratory rate estimation from the photoplethysmogram. IEEE Trans Biomed Eng. 2013;60(7):1946-1953.
Not in our library10.1109/tbme.2013.2246160
- 9.
Khalil A, Kelen G, Rothman RE. A simple screening tool for identification of community-acquired pneumonia in an inner city emergency department. Emergency Med J. 2007;24(5):336-338.
Not in our library10.1136/emj.2007.045989
- 10.
Fleming S, et al. Non-invasive measurement of respiratory rate in children using the photoplethysmogram. Proc Conf Proc Eng Med Biol Soc. 2008;1886-1889.
Not in our library10.1109/iembs.2008.4649554
- 11.
Seymour CW, et al. Assessment of clinical criteria for sepsis: For the third international consensus definitions for sepsis and septic shock (Sepsis-3). J Amer Med Assoc. 2016;315(8):762-774.
Not in our library10.1001/jama.2016.0288
- 12.
Cretikos MA, et al. Respiratory rate: the neglected vital sign. Med J Australia. 2008;188(11):657-659.
Not in our library10.5694/j.1326-5377.2008.tb01825.x
- 13.
Pimentel MAF, Charlton PH, Clifton DA, Mukhopadhyay SC. Wearable Electronics Sensors 15. 2015;241-262.
Not in our library10.1007/978-3-319-18191-210
- 14.
Goldhaber SZ, Visani L, De Rosa M. Acute pulmonary embolism: Clinical outcomes in the international cooperative pulmonary embolism registry (ICOPER). Lancet. 1999;353(2182):1386-1389.
Not in our library10.1016/s0140-6736(98)07534-5
- 15.
Lovett PB, et al. The vexatious vital: Neither clinical measurements by nurses nor an electronic monitor provides accurate measurements of respiratory rate in triage. Ann Emergency Med. 2005;45(1):68-76.
Not in our library10.1016/j.annemergmed.2004.06.016
- 16.
Philip KEJ, et al. The accuracy of respiratory rate assessment by doctors in a London teaching hospital: A cross-sectional study. J Clin Monit Comput. 2015;29(4):455-460.
Not in our library10.1007/s10877-014-9621-3
- 17.
Philip K, Richardson R, Cohen M. Staff perceptions of respiratory rate measurement in a general hospital. Brit J Nursing. 2007;22(10):570-574.
Not in our library10.12968/bjon.2013.22.10.570
- 18.
- 19.
Reisner AT, Clifford G, Mark RG, Clifford GD, Azuaje F, McSharry PE. Advanced Methods and Tools for ECG Data Analysis. 2006;1:1-25.
Not in our library
- 20.
Clifford G, Oefinger MB, Clifford GD, Azuaje F, McSharry PE. Advanced Methods and Tools for ECG Data Analysis. 2006;2:27-53.
Not in our library
- 21.
Walsh JA, Topol EJ, Steinhubl SR. Novel wireless devices for cardiac monitoring. Circulation. 2014;130(7):573-581.
Not in our library10.1161/circulationaha.114.009024
- 22.
Allen J. Photoplethysmography and its application in clinical physiological measurement. Physiol Meas. 2007;28(3):R1-R39.
Not in our library10.1088/0967-3334/28/3/r01
- 23.
Sun Y, Thakor N. Photoplethysmography revisited: From contact to noncontact, from point to imaging. IEEE Trans Biomed Eng. 2016;63(3):463-77.
Not in our library10.1109/tbme.2015.2476337
- 24.
van Gastel M, Stuijk S, de Haan G. Robust respiration detection from remote photoplethysmography. Biomed Opt Express. 2016;7(12):4941.
Not in our library10.1364/boe.7.004941
- 25.
Villarroel M, et al. Continuous non-contact vital sign monitoring in neonatal intensive care unit. Healthcare Technol Lett. 2014;1(3):87-91.
Not in our library10.1049/htl.2014.0077
- 26.
Shelley KH. Photoplethysmography: Beyond the calculation of arterial oxygen saturation and heart rate. Anesthesia Analgesia. 2007;105(6):S31-36.
Not in our library10.1213/01.ane.0000269512.82836.c9
- 27.
Tarassenko L, et al. Non-contact video-based vital sign monitoring using ambient light and auto-regressive models. Physiol Meas. 2014;35(5):807-831.
Not in our library10.1088/0967-3334/35/5/807
- 28.
Nam Y, Lee J, Chon KH. Respiratory rate estimation from the built-in cameras of smartphones and tablets. Ann Biomed Eng. 2014;42(4):885-898.
Not in our library10.1007/s10439-013-0944-x
- 29.
Karlen W, et al. Respiratory rate assessment from photoplethysmographic imaging. Proc Conf Proc Eng Med Biol Soc. 2014;5397-5400.
Not in our library10.1109/embc.2014.6944846
- 30.
Hubner P, et al. Surveillance of patients in the waiting area of the department of emergency medicine. Medicine. 2015;94(51):e2322.
Not in our library10.1097/md.0000000000002322
- 31.
Pimentel MA, et al. Towards a robust estimation of respiratory rate from pulse oximeters. IEEE Trans Biomed Eng. 2017;64(8):1914-1923.
Not in our library10.1109/tbme.2016.2613124
- 32.
Johansson A. Neural network for photoplethysmographic respiratory rate monitoring. Med Biol Eng Comput. 2003;41(3):242-248.
Not in our library10.1007/bf02348427
- 33.
Charlton PH, Villarroel M, Salguiero F. Secondary Analysis of Electronic Health Records. 2016;26:377-390.
Not in our library10.1007/978-3-319-43742-226
- 34.
Charlton PH, et al. Extraction of respiratory signals from the electrocardiogram and photoplethysmogram: Technical and physiological determinants. Physiol Meas. 2017;38(5):669-690.
Not in our library10.1088/1361-6579/aa670e
- 35.
Bailon R, Sornmo L, Laguna P, Clifford GD, Azuaje F, McSharry PE. ECG-derived respiratory frequency estimation. Advanced Methods and Tools for ECG Data Analysis. 2006;8:215-244.
Not in our library
- 36.
Nitzan M, Faib I, Friedman H. Respiration-induced changes in tissue blood volume distal to occluded artery, measured by photoplethysmography. J Biomed Opt. 2006;11(4):040506.
Not in our library10.1117/1.2236285
- 37.
Meredith DJ, et al. Photoplethysmographic derivation of respiratory rate: A review of relevant physiology. J Med Eng Technol. 2012;36(1):1-7.
Not in our library10.3109/03091902.2011.638965
- 38.
Berntson GG, Cacioppo JT, Quigley KS. Respiratory sinus arrhythmia: Autonomic origins, physiological mechanisms, and psychophysiological implications. Psychophysiology. 1993;30(2):183-196.
Not in our library10.1111/j.1469-8986.1993.tb01731.x
- 39.
Larsen PD, et al. Respiratory sinus arrhythmia in conscious humans during spontaneous respiration. Respiratory Physiol Neurobiol. 2010;174(1):111-118.
Not in our library10.1016/j.resp.2010.04.021
- 40.
Li J, et al. Comparison of respiratory-induced variations in photo-plethysmographic signals. Physiol Meas. 2010;31(3):415-425.
Not in our library10.1088/0967-3334/31/3/009
Cited by papers we hold 5
- Wearable Photoplethysmography for Cardiovascular Monitoring · 2022No notice
- Respiratory Induced Modulation in f-Wave Characteristics During Atrial Fibrillation · 2021Not checked
- The Importance of Respiratory Rate Monitoring: From Healthcare to Sport and Exercise · 2020No notice
- Modeling arterial pulse waves in healthy aging: a database for in silico evaluation of hemodynamics and pulse wave indexes · 2019No notice
- Contact-Based Methods for Measuring Respiratory Rate · 2019No notice
Reads
Read by people on this page
None yet.
Checked or read by AI through naulon
None yet.
A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.
Are you an author?
Is this your paper?
Claim it to add your note and be paid when agents cite it. Free.