Skip to content
naulon
Not checkedNot checked for notices yet.

A Novel Measurement Error Identification Framework for Multi-Branch CT System

Bolun Du, Yinglong Diao, Huan Wang and 3 more

IEEE Access · 2025

doi:10.1109/access.2025.3590166 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

The current transformer (CT) is recognized as a critical power conversion and metering device in substations, with its operational stability being considered crucial for grid reliability. A measurement error identification framework for error threshold-exceeding in multi-branch CT systems is proposed in the study. First, the secondary-side currents of each phase in multi-branch CTs are decomposed using robust empirical mode decomposition (REMD), with residuals being extracted to characterize current trend variations. The current residuals are then mapped into principal component space and residual space through kernel principal component analysis (KPCA), where the squared prediction error (SPE) in residual space is calculated as the error characteristic.The total SPE is generated as the summation of phase SPEs through accumulation of all branch CTs. During normal multi-branch CT operation, the total SPE is employed to establish error monitoring thresholds via adaptive kernel density estimation (AKDE) at 99% confidence level. When real-time total SPE surpasses the predetermined threshold, threshold-exceeding CT measurement errors are detected within the multi-channel CT system. Subsequently, the contribution rate of each branch CT’s relative threshold exceedance is calculated. The CT phase demonstrating the highest contribution rate is identified as the tolerance threshold-violating component. The proposed threshold-exceeding identification methodology has been validated through multiple experimental cases at the China Electric Power Research Institute. In all test scenarios, threshold-exceeding conditions were accurately detected within multi-branch CT systems, with both the non-compliant CTs and their specific phases being precisely identified.

Abstract licence: CC BY-NC-ND

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.