Research on Primary Frequency Regulation Control Strategy of Wind-thermal Power Coordination

Peihong Yang, Xiaoling Dong, Ya Li and 4 more

IEEE Access · 2019

doi:10.1109/access.2019.2946192 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

With the increase of wind power penetration in the electric grid, the frequency regulation method that simply reply on traditional power is gradually weakened. For this reason, the participation of wind power in system frequency regulation has become an inevitable trend in the operation of large-scale grid-connected power system. Focused on the essential difference of the frequency response speed between wind turbine and thermal power unit, a primary frequency regulation control strategy for large-scale wind power cooperative thermal power units is proposed to realize frequency regulation in the full wind speed range of doubly-fed wind turbines and improve the frequency response capability of large-scale wind power access to system. Firstly, the frequency regulation response strategy of wind turbine based on rotor kinetic energy control and power reserve control and the control strategy of rotor speed recovery are studied to improve the frequency regulation capability of wind power system. Secondly, the optimal distribution of frequency regulation power of the large-scale wind farms is realized according to the establishing of the power distribution strategy based on weight factor of each turbine in the wind farm in different operating scenarios Finally, the control framework of wind-thermal power coordination frequency regulation is constructed. The system power shortage is distributed to the wind farm and the thermal power unit in real time by the dispatch center according to the wind farms' and thermal power unit's operating states and the variation of system frequency, by which the wind-thermal power coordination frequency regulation of power system can be achieved. Simulation results of the 36-node test example demonstrate that the proposed strategy can effectively improve the frequency response capability and the frequency characteristics of the power system.

Abstract licence: CC BY-NC-ND

References17

    17 more references, whose wording the paper’s licence keeps private.

    Reads

    Read by people on this page

    None yet.

    Checked or read by AI through naulon

    None yet.

    A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

    Are you an author?

    Is this your paper?

    Claim it to add your note and be paid when agents cite it. Free.