New energy-spread-feedback control system using nondestructive energy-spread monitors
T. Suwada, M. Satoh, K. Furukawa
Physical Review Special Topics. Accelerators and Beams · 2005
doi:10.1103/physrevstab.8.112802 (opens in a new tab)
We email you when a new notice or a question about this paper appears.
Abstract
A new energy-spread feedback control system using nondestructive energy-spread monitors has been developed in order to control and stabilize the energy spreads of single-bunch electron and positron beams in the KEKB injector linac. A well-controlled feedback system has been successfully working in daily operation not only for keeping the injection rate higher along with the beam-orbit and energy-feedback control system, but also for reducing the background level to the KEKB collider experiment. The energy spreads of the injection beams have been well stabilized within 0.33±0.01% and 0.50±0.02% (0.55±0.06%) for the electron beam and the first (second) bunch of the high-current primary electron beam for positron production at the 180° arc, respectively, and within 0.39±0.01% (0.36±0.03%) for the first (second) bunch of the positron beam at the end of the injector linac through the energy-spread feedback control system under the nominal operation condition. In this report we describe in detail the energy-spread feedback control system using nondestructive energy-spread monitors with multi–strip-line electrodes and their performance in KEKB operation.
Abstract licence: CC BY
Reads
Read by people on this page
None yet.
Checked or read by AI through naulon
None yet.
A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.
Are you an author?
Is this your paper?
Claim it to add your note and be paid when agents cite it. Free.