Abstract 26: Assessing Efficiency in Microsurgery Using Motion Tracking Technology
Sarah Lyon, MD, Weifeng Zeng, MD, Nicholas Albano, MD and 4 more
Plastic and Reconstructive Surgery, Global Open · 2020
doi:10.1097/01.gox.0000672616.91764.09 (opens in a new tab)
We email you when a new notice or a question about this paper appears.
Abstract
Background: A high level of precision as well as controlled, efficient motions are important components of microsurgical technique and success. The current Halstedian model of resident microsurgical education confers this expertise in the operating room wherein residents acquire skills while operating on patients with the guidance of an experienced attending. This study captures and compares motion patterns of microsurgeons in various career stages in a lab-based anastomosis model. We employ motion tracking technology to analyze hand and instrument motion to identify critical areas for trainee improvement. Methods: Plastic surgeons with varying levels of microsurgical experience performed end-to-end microsurgical anastomoses on a validated blue blood chicken thigh model in a laboratory setting. Each microsurgeon was equipped with motion-tracking sensors connected to standardized positions on their hands and to the microsurgical instruments. Vessel branches <3 mm diameter were anastomosed using an end-to-end technique. The time, total path length and jerkiness of motion for components of each anastomosis (suture approach to vessel, passage of needle through vessel walls, knot tying) were calculated using sensor derived position data. Results: Two fellowship-trained microsurgeons (expert), one PGY4 (intermediate), and one PGY1 (novice) plastic surgery resident participated in the study. A total of eight anastomoses were captured and analyzed. Representative expert and novice motion maps were created to track hand and sensor motion in the x, y and z planes for the entirety of the respective anastomoses. Aggregated position data demonstrate that novices have a significantly longer time, path length and greater jerkiness for the majority of each time phase. Conclusion: Resident work hour restrictions and an emphasis on competency-based training create an increasing need for validated laboratory-based methods for microsurgical education. Path length, jerkiness and time comparisons among novice, intermediate and expert microsurgeons objectively demonstrate areas of improvement in resident motion efficiency. Quantifiable motion parameters can provide a basis for structured resident feedback and competency assessment in microsurgery.
Abstract licence: CC BY-NC-ND
Reads
Read by people on this page
None yet.
Checked or read by AI through naulon
None yet.
A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.
Are you an author?
Is this your paper?
Claim it to add your note and be paid when agents cite it. Free.