Not checkedNot checked for notices yet.
Sound insulation effect of magnetorheological fluid as a function of magnetic field strength and direction
Hao Cheng, Taeuk Lim, Sunghoon Kim and 1 more
Materials Research Letters · 2022
doi:10.1080/21663831.2022.2050431 (opens in a new tab)
We email you when a new notice or a question about this paper appears.
Abstract
We developed a sound absorber using a magnetorheological fluid(MR-F) based on the density and alignment angle of carbonyl iron powder(CIP) chains by the controlling the magnetic field strength and direction. The magnetically arranged CIP lattice structure considerably influenced the sound transmission loss(STL). We used optical microscopy, energy-dispersive X-ray spectrometry, and X-ray diffraction to investigate the STL by varying the magnetic field strength from 0 to 40 mT and the angle from 0 to 30°. The STL was markedly increased (133%) owing to an ∼10-fold increased density and the CIP alignment. These results were verified using the developed MR-F porous model.
Abstract licence: CC BY-NC
Reads
Read by people on this page
None yet.
Checked or read by AI through naulon
None yet.
A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.
Are you an author?
Is this your paper?
Claim it to add your note and be paid when agents cite it. Free.