Heart rate control using first- and second-order models during treadmill exercise
Hanjie Wang, Kenneth J. Hunt
Systems Science & Control Engineering · 2021
doi:10.1080/21642583.2021.1976304 (opens in a new tab)
We email you when a new notice or a question about this paper appears.
Abstract
Heart rate control using first- and second-order models was compared using a novel control design strategy which shapes the input sensitivity function. Ten participants performed two feedback control test series on a treadmill with square wave and constant references. Using a repeated measures, counterbalanced study design, each series compared controllers C1 and C2 based on first- and second-order models, respectively. In the first series, tracking accuracy root-mean-square tracking error (RMSE) was not significantly lower for C2: 2.59 bpm vs. 2.69 bpm (mean, C1 vs. C2), p = 0.79. But average control signal power was significantly higher for C2: $ 11.29 \times 10^{-4}\,{\rm m}^2/{\rm s}^2 $ vs. $ 27.91 \times 10^{-4}\,{\rm m}^2/{\rm s}^2 $, $ p = 3.1 \times 10^{-10} $. In the second series, RMSE was also not significantly lower for C2: 1.99 bpm vs. 1.94 bpm, p = 0.39; but average control signal power was again significantly higher for C2: $ 2.20 \times 10^{-4}\,{\rm m}^2/{\rm s}^2 $ vs. $ 2.78 \times 10^{-4}\,{\rm m}^2/{\rm s}^2 $, p = 0.045. The results provide no evidence that controllers based on second-order models lead to better tracking accuracy, despite the finding that they are significantly more dynamic. Further investigation using a substantially larger sample size is warranted.
Abstract licence: CC BY-NC
Reads
Read by people on this page
None yet.
Checked or read by AI through naulon
None yet.
A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.
Are you an author?
Is this your paper?
Claim it to add your note and be paid when agents cite it. Free.