Skip to content
naulon

Not checkedNot checked for notices yet.

Air-coupled PMUTs array with residual stresses: experimental tests in the linear and non-linear dynamic regime

Gianluca Massimino, Borka Lazarova, Fabio Quaglia and 1 more

International Journal of Smart and Nano Materials · 2020

doi:10.1080/19475411.2020.1834003 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

The mechanical characterization of a 4 × 4 air-coupled array of Piezoelectric Micromachined Ultrasonic Transducers (PMUTs) is presented. The experimental campaign consists of three set of experimental tests, namely: topography measurements, small signal dynamic measurements, and vibrometry in the non-linear dynamic regime. The behavior of three different kinds of PMUT are reported. They differ according to the thermo-electrical treatment that has been applied to the piezoelectric material. The presence of the fabrication induced residual stresses is investigated and the treatment effect is evaluated in terms of the initial deflected configuration. The results reported in this paper represent an experimental mechanical investigation useful for the design of PMUT structures with advanced functionalities in the linear and non-linear regime.

Abstract licence: CC BY-NC

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.