Reference Values for Shear Wave Elastography of Neck and Shoulder Muscles in Healthy Individuals

Caroline Ewertsen, Jonathan Carlsen, Mohammed Aftab Perveez and 1 more

Ultrasound International Open · 2018

doi:10.1055/s-0044-102013 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

Purpose to establish reference values for ultrasound shear-wave elastography for pericranial muscles in healthy individuals (m. trapezius, m. splenius capitis, m. semispinalis capitis, m. sternocleidomastoideus and m. masseter). Also to evaluate day-to-day variations in the shear-wave speeds and evaluate the effect of the pennation of the muscle fibers, ie scanning parallel or perpendicularly to the fibers. Materials and Methods 10 healthy individuals (5 males and 5 females) had their pericranial muscles examined with shear-wave elastography in two orthogonal planes on two different days for their dominant and non-dominant side. Mean shear wave speeds from 5 ROI’s in each muscle, for each scan plane for the dominant and non-dominant side for the two days were calculated. The effect of the different parameters – muscle pennation, gender, dominant vs non-dominant side and day was evaluated. Results The effect of scan plane in relation to muscle pennation was statistically significant (p<0.0001). The mean shear-wave speed when scanning parallel to the muscle fibers was significantly higher than the mean shear-wave speed when scanning perpendicularly to the fibers. The day-to-day variation was statistically significant (p=0.0258), but not clinically relevant. Shear-wave speeds differed significantly between muscles. Mean shear wave speeds (m/s) for the muscles in the parallel plane were: for masseter 2.45 (SD:+/−0.25), semispinal 3.36 (SD:+/−0.75), splenius 3.04 (SD:+/−0.65), sternocleidomastoid 2.75 (SD:+/−0.23), trapezius 3.20 (SD:+/−0.27) and trapezius lateral 3.87 (SD:+/−3.87). Conclusion The shear wave speed variation depended on the direction of scanning. Shear wave elastography may be a method to evaluate muscle stiffness in patients suffering from chronic neck pain.

Abstract licence: CC BY-NC-ND

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.